HomeKing BYHG604.5SS Скачать руководство пользователя страница 25

 

25

IMPORTANT: Before carrying out any maintenance operations, 
disconnect the appliance from the gas and electricity supplies. 

 

If a gas tap becomes stiff to operate, then you should proceed as 
follows: 
 

o

 

Remove the control knobs, pan supports, burners, hob fixing 
screws and clamps. 

 

o

 

Remove the hob from the worktop and remove any underside 
protective covers. 

 

o

 

Disconnect the fixings holding the tap to the fascia panel and 
separate the assembly. Then clean the cone and seating, with 
a cloth dampened with solvent. 

 

o

 

Lightly smear the cone with high temperature grease, 
reassemble into position and rotate a few times. 

 

o

 

Remove the cone again and remove any excess grease, 
making sure that the gas ducts are not obstructed with 
grease. 

 

o

 

Carefully reassemble the components and perform a gas 
soundness test. 

 
If it becomes necessary to replace a gas tap, then you should proceed 
as follows: 
 

o

 

Remove the control knobs, pan supports, burners, hob fixing 
screws and clamps. 

 

o

 

Remove the hob from the worktop and remove any underside 
protective covers. 

 

o

 

Disconnect the fixings holding the tap to the fascia panel and 
separate the assembly. 

 

o

 

Disconnect the gas pipe from the gas tap, and then 
disassemble them from the gas rail by removing the fixing 
screws. 

 

o

 

When fitting a new tap, ensure that a new gasket is used. 

 

o

 

Reconnect the gas tap, perform a gas soundness test and 
then reassemble the hob. 

 
 
 

Содержание BYHG604.5SS

Страница 1: ...ser Instruction Manual contains important information including safety installation points which will enable you to get the most out of your appliance Please keep it in a safe place so that it is easi...

Страница 2: ...4 15 Cleaning the hob top 14 After each use 14 Cleaning the hob burners 14 Maintaining the pan stands 15 Installation 19 26 Positioning 17 Unpacking the appliance 18 Installing the appliance 18 Gas co...

Страница 3: ...Environmental note 3 o The packaging materials that the manufacturer uses are environmentally friendly and can be recycled all packaging material with due regard for the environment o Please discard...

Страница 4: ...als used in the installation must be able to withstand a minimum temperature of 85 C above the room it is located in whilst in use o Certain types of vinyl or laminate kitchen furniture are particular...

Страница 5: ...ones are switched off after use leaning Cleaning of the hob should be carried out on a regular basis appliance it should be disconnected from the mains and cool C o We strongly recommend that babies a...

Страница 6: ...es only o Great care should be taken whilst o You should not use a steam jet or any Installation This appliance must be correctly installed by a GASSAFE registered installer strictly in accordance wit...

Страница 7: ...10 mm Width 620 mm D W epth 480 mm Height 50 mm Product specifications o 1 x 3 00 kW rapid burner o 2 x 1 75 kW semi rapid burne o 1 x 1 00 kW auxiliary bu o Front control operation o Enamelled pan st...

Страница 8: ...fications o 2 x 1 75 kW semi rapid burner 1 x 1 00 kW auxiliary burner o o 1 x 3 50 kW triple crown wok b Front control operation o o Heavy duty cast iron pan stands o Automatic ignition o Flame failu...

Страница 9: ...burners o 1 x 1 00 kW auxiliary burner o 1 x 3 50 kW triple crown wok burner o Front control operation o Heavy duty cast iron pan stands o Automatic ignition o Flame failure safety device on each burn...

Страница 10: ...mbar Alternative LPG G30 28 30 37 mbar For future reference please record the following information which can be found on the rating plate and the date of purchase which can be found on your sales inv...

Страница 11: ...ff Large flame maximum setting ignition position Small flame minimum setting o The minimum setting is at the end of the anti clockwise rotation of the control knob o All operation positions must be se...

Страница 12: ...the control knob depressed the automatic ignition for the burner will operate o You should hold down the control knob for 20 seconds after the flame on the burner has lit o After this 20 second interv...

Страница 13: ...ever extend beyond the diameter of the pan o Use flat bottomed pans only o When possible keep a lid on the pan whilst cooking o Cook vegetables with as little water as possible to reduce cooking times...

Страница 14: ...ore you attempt to touch them After each use o Remove the pan stands and wipe the appliance over with a soft damp cloth that has been put into warm soapy water The cloth should be wrung out after bein...

Страница 15: ...he cloth should be wrung out after being taken out of the soapy water o Using a paper towel thoroughly dry the pan stands Maintaining the cast iron pan stands BYHG610 5SS BYHG710 5SS o IMPORTANT Make...

Страница 16: ...ons issued by the Department of Environment o Building Standards Issued by the Scottish Development Department o IEE Wiring Regulations o Electricity at Work Regulations BS 6172 o Installation of Dome...

Страница 17: ...must be observed o 700 mm between the hob surface and the underside of any horizontal surface above it o 50 mm clearance around the front back and sides of the appliance measured from the cut out o T...

Страница 18: ...Instruction manual Warranty card Fixing screws Clamps Sealing strip LPG conversion jets Self adhesive label for amending the gas category on the appliance s rating plate required if the LPG conversio...

Страница 19: ...he aperture This will make it difficult to remove the hob from the aperture in future particularly if it needs to be serviced A Sealing strip B Clamp C Screw o Place the clamp B over the holes that ma...

Страница 20: ...other type of gas without modification o Conversion for use on LPG and other gases must only be undertaken by a qualified person For information on the use of other gases please contact the Customer...

Страница 21: ...om the current edition of BS 5440 Part 2 should be consulted to determine air vent requirements o Ensure that the room containing the hob is well ventilated keep natural ventilation holes or install a...

Страница 22: ...E registered installers work to safe standards of practice The cooker must also be installed in accordance with the current edition of BS 6172 Failure to install the hob correctly could invalidate the...

Страница 23: ...y see the table on the next page PRESSURE INJECTOR THERMAL CAPACITY GAS TYPE mbar BURNER 1 100 mm Nominal W CONSUMPTION Triple crown 141 3500 333 Rapid 129 3000 286 Semi rapid 101 1750 167 Natural gas...

Страница 24: ...increase the gas flow or tighten the adjusting screw to decrease the gas flow o The correct adjustment is obtained when the flame has a length of about 3 4 mm o For butane propane gas the adjusting sc...

Страница 25: ...nd rotate a few times o Remove the cone again and remove any excess grease making sure that the gas ducts are not obstructed with grease o Carefully reassemble the components and perform a gas soundne...

Страница 26: ...then it must be replaced by an appropriate replacement which can be obtained from the Spares Department The mains supply cable should be replaced in accordance with the following instructions o Switc...

Страница 27: ...ible for the engineer to perform any necessary repair If your appliance is installed in such a way that an engineer is concerned that damage will be caused to the appliance or your kitchen then he wil...

Страница 28: ...28 United Kingdom 6 Bennet Road Reading Berkshire RG2 0QX United Kingdom Customer Care 0118 933 6918...

Отзывы: