![Homefront RF-360T Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/homefront/rf-360t/rf-360t_user-manual_2152821009.webp)
17
Black
Line (Hot)
Neutral
Signal
White
Red
Black
Line (Hot)
Neutral
Signal
White
Red
How to Wire and Mount the AC Powered Alarm
When installing an AC powered alarm (Model RF-360TEB), the mounting location is
determined by the position of the electrical box that will power the alarm.
Electrical
power to the box must be disconnected prior to alarm connection and
installation!
With the AC power turned off
, connect
the wire harness provided with the alarm.
Connect the black wire of the harness to
the black wire(s) in the electrical box.
Typical
Circuit
End of
Line
Circuit
Align and attach the mounting bracket
with the two screws from the electrical
box. Pass the wire harness through the
center of the bracket.
Plug the wire harness into the back of the
alarm.
Press and twist the alarm clockwise into
place (see Step 4 of previous section).
Reconnect power to the AC lines of the
smoke alarm circuit. The POWER icon will
glow continuously.
Using the supplied orange wire nut, cap
the red wire (not used) and push it back
inside the electrical box.
Connect the white wire of the harness to
the white wire(s) in the electrical box.
18
Cleaning Your Alarm
/
/
/
/
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/ /
/ / / / / / /
/ /
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Over time dust might collect inside your alarm, altering its performance. If this
occurs, the WARNING icon will flash and the horn will chirp once per minute. To
clean the alarm perform the following:
Remove the alarm from its bracket. With an
AC powered alarm the wire harness must be
disconnected.
Using a coin as a screwdriver, rotate the 4
corner slots on the back of the alarm counter-
clockwise and carefully separate the two
halves of the alarm.
Twist the round bug shield counter-clockwise
to remove.
Vacuum all the internal surfaces carefully.
Wipe with a clean cloth.
Reassemble the alarm. Rotate the 4 corner
slots clockwise to tighten.
Re-install the batteries. All four lighted icons
will strobe on and the WARNING icon should
no longer flash. Re-mount the alarm on the
wall or ceiling.
If the WARNING icon flashing persists,
return the alarm to the manufacturer.
The removed bug shield can be rinsed with
water when removed from the alarm. Allow
to air dry completely before reinstalling.
Do not submerge the complete smoke
alarm in water. The sensitive electronics
will be damaged!