4
I
GB
CLEANING THE HEPA-TYPE
FILTER
NOTE:
For best performance,
vacuum the HEPA-type filter once
a month under normal usage.
1. Unplug the air purifier.
2. Remove the HEPA-type filter
as described in the Replacing the HEPA Type Filter section.
3. Vacuum the white side of the HEPA-type filter using the brush
attachment of your vacuum cleaner, cleaning it thoroughly.
4. Place the HEPA-type filter back into the air purifier and close
grille.
5. Plug the power cord into a standard AC outlet.
TO CLEAN THE OIL TRAY
Open the oil tray and remove the
pad. Essential oil pads should be
changed when switching to a
different essential oil scent. If
continuing to use the same scent,
set the essential oil pad aside for
reuse. Wipe down the inside of the
oil tray with a soft cloth. Place the essential oil pad back in the tray
and close.
NOTE:
Leave the essential oil pad out of the oil tray when storing.
FOR BEST PERFORMANCE
• NEVER use water or any household cleaners or detergents to
clean the HEPA-type filter.
• Clean off the outside of the unit with a dry cloth as needed.
• NEVER use water, wax, polish, or any chemical solution to clean
the outside of the unit.
• Clean off the grille cover using a damp cloth or the brush
attachment of your vacuum as needed.
• Vacuum the pre-filter monthly under normal usage conditions.
• Replace the HEPA-type filter every 12 months under normal
usage conditions.
• Always use a genuine HoMedics replacement filter for optimal
performance.
To purchase genuine HoMedics replacement/spare parts please
visit www.homedics.co.uk
3 Pack of aroma pads - ARM-PAD3
Aroma tray - AP-DT10ARMTR
HEPA filter - AP-DT10FL
CLEANING & MAINTENANCE
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit will not operate
• Unit is not plugged in
• Power button not pressed
• No power to unit
• Plug unit in
• Press the power button to turn the power on
• Check fuses, try a different outlet
Reduced airflow
• The back grille may be blocked
• Pre-filter needs vacuuming
• The filter needs to be replaced
• Check to make sure nothing is blocking the
back grille and air outlet
• Vacuum the pre-filter with the brush
attachment of your vacuum cleaner
• Replace the filter
Reduced odour removal
• The filter needs to be replaced
• Replace the filter
Excessive noise
• The unit is not level
• Place the unit on a flat, level surface
Replace filter light remains lit
after filter replacement
• The replace filter indicator needs to be
reset
• Press and hold the ioniser button for 3 seconds
until the replace filter light turns off
TROUBLESHOOTING
Содержание TotalClean AP-DT10