Warning:

 To prevent fire or possible burns:

1. 

Keep away from flammable aerosol products being 

used or where oxygen is being administered. 

2. 

Turn off the device if it becomes unusually warm to touch.

Warning: 

Stop immediately if you experience any adverse 

effects or develop prolonged redness. You may be 

experiencing a photosensitive reaction. 

Precautions

• 

Read all instructions before using your Zap device.

• 

Use this device only for its intended use as described  

in this manual. Failure to do so may result in a delay  

in receiving appropriate treatment. 

• 

Discontinue use if you encounter any discomfort.  

You may be sensitive to light. 

• 

Do not look directly at the light source of the treatment 

head of this device while it is operating. Failure to do so 

may result in a headache or damage to the eyes.

IB-TandaZapEN-1011-01.indd   6

26/10/2011   08:52

Содержание Tanda Zap

Страница 1: ...instructions for use TandaZapEN 1011 01 indd 1 26 10 2011 08 5 ...

Страница 2: ...Customer service contact HoMedics Group Ltd Somerhill Business Park Five Oak Green Road Tonbridge Kent TN11 0GP UK email tandaservice homedics co uk TandaZapEN 1011 01 indd 2 26 10 2011 08 5 ...

Страница 3: ...erful blue LED light destroys acne causing bacteria while sonic vibration and gentle warming help open pores so bacteria have nowhere to hide No pain No dryness No irritation And best of all no spot Device components Zap treatment head 1 Indicator light 2 Power button 3 Battery compartment opening 4 1 3 4 2 TandaZapEN 1011 01 indd 1 26 10 2011 08 5 ...

Страница 4: ... any lesion other than mild to moderate acne Doing so can result in delaying the best medical treatment CAUTION Do not allow children under the age of 14 to use this device unsupervised doing so can result in injury to eyes CAUTION Do not use if you are sensitive to light Doing so may result in a photosensitive reaction It is recommended that you test a small less sensitive patch of skin i e like ...

Страница 5: ... Lightly place and hold the Zap on your inner arm for the 2 minute treatment cycle 4 Press the orange power button again to do another 2 minute treatment on the same area of your inner arm 5 Wait 24 hours You should NOT experience any adverse reaction during the next 24 hours 6 An adverse reaction is pain or discomfort in the treatment areas or any prolonged skin redness TandaZapEN 1011 01 indd 3 ...

Страница 6: ... Sulfa Drugs CAUTION Do not use with liniments salves or ointments that contain heat producing ingredients which could result in skin burn CAUTION Do not use over or near a recent steroid injection Doing so may result in a photosensitive reaction CAUTION Do not use on or around your eyes or eyelids and do not stare directly into the blue light This could cause serious eye injury including blindnes...

Страница 7: ...s device Never operate this device if it is not working properly if it has been dropped or damaged or submerged in water Return the device to HoMedics Service Centre for examination and repair Remove the batteries from the device if you anticipate that it will not be used for a significant period of time such as one month Do not disassemble the device as this may cause unit damage malfunction elec...

Страница 8: ...g a photosensitive reaction Precautions Read all instructions before using your Zap device Use this device only for its intended use as described in this manual Failure to do so may result in a delay in receiving appropriate treatment Discontinue use if you encounter any discomfort You may be sensitive to light Do not look directly at the light source of the treatment head of this device while it ...

Страница 9: ... you think you may be sensitive to light you should not use the Zap device without doing a light sensitivity test first Refer to light sensitivity test described on page 3 Steps 1 Press the orange power button 2 The device will vibrate and the bacteria killing blue light will illuminate Do not stare directly into the beam of light 3 Lightly place and hold the Zap device over your blemish for 2 min...

Страница 10: ... 30 seconds the device will count the treatment Your Zap device delivers 1000 uses When your Zap has less than 50 treatments remaining the orange power button will glow a steady red after each treatment to remind you that you need to get a replacement Once your Zap has completed the 1000 treatments the device will no longer turn on and the orange power button with glow a steady red TandaZapEN 1011...

Страница 11: ...conds after each treatment The device has less than 50 treatments remaining Device will not turn on and orange power button is a solid red for 10 seconds The device is out of treatments Time to buy a new Zap Battery life and replacement When your Zap batteries are running low the orange power button will blink red after each treatment as an indication When replacement is needed use AAA alkaline ba...

Страница 12: ...follow these instructions 1 Turn the top of the device counter clockwise to align the two triangles located on the top and bottom of the 2 sections of the device 2 Remove the used batteries from the battery holder 3 Install 3 new AAA batteries according to the symbols located on the battery holder 4 To close the Zap device align the two triangles push and turn the top of the device clockwise until...

Страница 13: ...atment surface Note Do not immerse device in water at any time This symbol indicates that batteries must not be disposed of in the domestic waste as they contain substances which can be damaging to the environment and health Please dispose of batteries in designated collection points TandaZapEN 1011 01 indd 11 26 10 2011 08 5 ...

Страница 14: ...ES 4 TYPE BF APPLIED PART Attention consult ACCOMPANYING DOCUMENTS RISK GROUP 2 CAUTION Possibly hazardous optical radiation emitted from this product Do not stare at operating lamp May be harmful to your eyes TandaZapEN 1011 01 indd 12 26 10 2011 08 5 ...

Страница 15: ...ndicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They ...

Страница 16: ...f the productis purchased and operated in the UK EU A product that requires modification or adaptation to enable it to operate in any country other than the country for which it was designed manufactured approved and or authorised or repair of products damaged by these modifications is not covered under this guarantee HoMedics shall not be responsible for any type of incidental consequential or sp...

Страница 17: ...u post paid Guarantee is solely through HoMedics Service Centre Service of this product by anyone other than the HoMedics Service Centre voids the guarantee This guarantee does not affect your statutory rights HoMedics Service Centre HoMedics Group Ltd Somerhill Business Park Five Oak Green Road Tonbridge Kent TN11 0GP UK email tandaservice homedics co uk TandaZapEN 1011 01 indd 15 26 10 2011 08 5...

Страница 18: ...homedics co uk 16 www homedics co uk IB TandaZapEN 1011 01 TandaZapEN 1011 01 indd 16 26 10 2011 08 5 ...

Отзывы: