HoMedics AR-20 Скачать руководство пользователя страница 3

4

5

• To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not 

use on soft surface, like a bed, where openings may become blocked.

• Use this air cleaner only for its intended use as described in this manual.  Any other 

use not recommended by the manufacturer may cause fire, electric shock, or injury 
to persons.

•  Always plug the air cleaner directly into a wall outlet/receptacle. Never use with an 

extension cord or relocate power tap (outlet/power strip).

CAUTION: Avoid the use of an extension cord because the extension cord 
may overheat and cause a risk of fire. However, if you have to use an 
extension cord, the cord should be No. 14 AWG minimum size and rated not 
less than 1875 watts.

• DO NOT use outdoors.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE

Technical Specifications

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause 
undesired operation.
Note: The manufacturer is not responsible for any radio or TV interference caused by 
unauthorized modifications to this equipment. Such modifications could void the user 
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. 

Main Features on the Professional HEPA Air Cleaner

Input voltage

120 V

Rated Frequency

60 HZ

Power

65 Watts

Weight

11.25 lbs

Noise Level

<60 dB

Unit Height

18.5 inches

Control Panel

 Main Unit 

HEPA Filter

Front Grill Plate

Содержание AR-20

Страница 1: ...ricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS CUBIERTOS POR ESTA...

Страница 2: ...r cleaner into a circuit that already has other appliances working CAUTION It is normal for the plug to feel warm to the touch however a loose fit between the AC outlet receptacle and plug may cause overheating and distortion of the plug Contact a qualified electrician to replace loose or worn outlet WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Extreme caution is ne...

Страница 3: ...his device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment Note This equipment has been tested a...

Страница 4: ...ntact a qualified electrician DO NOT attempt to defeat this safety feature To do so could result in an electric shock hazard Control Panel Operating Instructions Turning the Unit On Take the air cleaner out of the box and remove the clear protective plastic bag Place the air cleaner on a firm level surface Before turning the air cleaner ON you need to confirm that the filter is firmly in place and...

Страница 5: ...o hours 4 four hours 6 six hours 8 eight hours 10 ten hours and 12 twelve hours To activate the timer and select a time setting press TIMER on the control panel Each time the TIMER function is pressed it will switch between settings in a repeating cycle as follows 2 hours 4 hours 6 hours 8 hours 10 hours 12 hours OFF Press again and the cycle begins again The selection will light up on the LED con...

Страница 6: ... the HEPA filter is ready to be cleaned the LED CLEAN FILTER indicator will light up on the control panel Once the permanent HEPA filter has been cleaned press and hold the CLEAN FILTER button to reset the Indicator until it beeps Cleaning the HEPA Filter Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning 1 Open the front grill by gently pulling on the tabs ...

Страница 7: ...ven surface Troubleshooting 5 Place the clean HEPA filter back in the main unit making sure that it is firmly seated inside the unit 6 Place the tabs at the bottom of the grill plate into the base of the unit Gently push the grill plate back into place until you hear a click sound indicating that the grill is firmly latched DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE HEPA...

Страница 8: ...ics This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARR...

Страница 9: ...a caliente al tacto sin embargo un encaje flojo entre el tomacorriente de CA receptáculo y el enchufe puede provocar el recalentamiento y la deformación del enchufe Póngase en contacto con un electricista calificado para reemplazar el tomacorriente flojo o gastado ADVERTENCIA PARA REDUCIR EL RIESGO DE QUEMADURAS CHOQUE ELÉCTRICO INCENDIO O LESIONES A LAS PERSONAS Se debe ser extremadamente precavi...

Страница 10: ...RA SU FÁCIL REFERENCIA Especificaciones técnicas Características principales en el aire HEPA Cleaner Professional Panel de control Unidad principal HEPA Filter Frente PLAT Parrilla Tensión de entrada 120V Frecuencia nominal 60 HZ Potencia 65 vatios Peso 11 25 lbs Nivel de Ruido 60 dB Unidad de altura 18 5 pulgadas Declaración de la FCC Este dispositivo cumple con la Parte 15 de las Normas FCC El f...

Страница 11: ...ente en el tomacorriente invierta el enchufe Si aún así no encaja póngase en contacto con un electricista calificado NO intente destruir esta característica de seguridad Hacerlo podría tener como resultado un peligro de choque eléctrico Panel de control Instrucciones de uso Para encender la unidad Retire el limpiador de aire de la caja y quite la bolsa plástica protectora trasparente Coloque el li...

Страница 12: ...a gaveta NOTA siempre mantenga la pila y el control remoto fuera del alcance de los niños 1 Encendido apagado y configuración de velocidad To turn the air cleaner on press the ON OFF button on the control panel When the air cleaner is on the LED light in the ON OFF button on the control panel will be lit and the air cleaner will start to operate on LOW speed Once the air cleaner is ON press the SP...

Страница 13: ...e aire La placa de la rejilla puede limpiarse con un paño húmedo o con el accesorio de cepillo de su aspiradora NO USE AGUA CERA LUSTRADOR NI NINGUNA SOLUCIÓN QUÍMICA Indicador de limpiar filtro El limpiador de aire cuenta con un indicador CLEAN FILTER limpiar filtro para avisar al usuario cuando sea momento de limpiar el filtro HEPA aproximadamente cada 2 800 horas de uso Cuando el filtro HEPA es...

Страница 14: ...nidad Conecte la unidad Pulse el botón POWER a conectar la alimentación Revise los circuitos fusibles pruebe con un toma diferente Reducción del flujo de aire filtrado o pobres La parrilla delantera se puede bloquear El filtro HEPA puede estar obstruida Verifique que nada esté bloqueando la rejilla frontal y salida de aire Revise y limpie el filtro Reemplace el filtro El ruido excesivo La unidad n...

Отзывы: