15
Operating Instructions
Pump drain
The max. height of pump drainage is about 16.4 feet. Take below steps to start the Pump drain.
1. Connect the pump 16.4 feet drain pipe to the back of the unit.
2.
Put the unit on level floor. Unscrew the cap on the back of the unit.
3. Install the pump adapter and the gasket.
4. Install the drain pipe to the drain connector.
5. Press the POWER button to run the unit, and then press the PUMP button to start the pump drain
function. The PUMP indicator will light up.
Note:
• After the pump is activated, water will not run out of the drain hose right away as there is a small,
internal tank which must be filled first.
• Make sure there are no kinks or knots in the drain hose.
AUTOMATIC DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run
until the frost disappears. When the coils are completely defrosted, the compressor or fan (depending on
the model) will automatically restart. The unit start to dehumidify the room.