4

www.homewerksww.com

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install  
the product.

1.  Always disconnect the power supply prior to servicing the fan, motor or junction box.
2. 

Installation work must be carried out by a qualified person(s) in accordance to all local and 

 

safety codes including the rules for fire-rated construction.

3. 

Follow all local building, safety and electrical codes as well as NEC (National Electrical Code) 
and OSHA (Occupational Safety and Health Act).

4.  Electric Service supply must be 120 volts, 60 hertz.
5.  This unit must be properly grounded.
6.  Do not bend or kink the power wires.
7.  Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
8. 

Sufficient air supply is required for proper combustion and the exhaustion of gases through 

 

the chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of 

 

NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating 

 

Refrigeration and Air Conditioning Engineers) and the local building code authorities.

9.  Do not use this fan with any solid state control device, such as a remote control, dimmer switch,  

or certain timers. Mechanical timers are not solid state devices.

10.  This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI  

protected circuit. Do not use fans over a bathtub or shower that are not approved for that  
application and marked accordingly.

11.  Do not install in a cooking area.
12.  Do not use to exhaust hazardous or explosive vapors.
13.  Fans should always be vented to the exterior and in compliance with local codes.
14. 

Do not install in a ceiling with insulation greater than R42.

15.  Duct work should be installed in a straight line with minimal bends.
16. 

Duct work size must be the same size as the discharge and should not be reduced. Reducing 

 

the duct size may increase fan noise.

17.  Prior to service or cleaning this unit, shut off power supply at the panel and lock to  

prevent the power from being turned on. If the panel cannot be locked, clearly mark  
the panel with a warning tag to prevent the power from being turned on.

18.  Use this unit in the manner intended by the manufacturer. If you have any questions. Please  

call customer service.

19. 

The fan is intended to be mounted at least 7.6 ft. above the floor.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package 
contents list and hardware contents. If any part is missing or damaged, do not attempt to assemble 
the product. Contact customer service for replacement parts at 1-877-319-3757, 8 a.m. - 5 p.m., CST, 
Monday - Friday.

Содержание 7130-02-BT

Страница 1: ...8V cjVYx Questions problems missing parts Before returning to your retailer call our customer service department at 1 877 319 3757 8 a m 5 p m CST Monday Friday The BLUETOOTH word mark and logos are registered trademarks owned by BLUETOOTH SIG Inc and any use of the said mark by Homewerks Worldwide is under license Other trademark and trade names are those of their respective owners READ AND SAVE ...

Страница 2: ...modifications or changes to this equipment Such modifications or changes could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment...

Страница 3: ...d Screw Short Machine Screw Qty 8 Qty 3 PACKAGE CONTENTS A G B C E D NIGHT LIGHT PART DESCRIPTION QTY A Fan body 1 B Grille w BLUETOOTH speakers and light 1 C Suspension Bracket I 1 PART DESCRIPTION QTY D Suspension bracket II 1 E Suspension Bracket III 1 G Wall switch 1 ...

Страница 4: ... timers are not solid state devices 10 This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit Do not use fans over a bathtub or shower that are not approved for that application and marked accordingly 11 Do not install in a cooking area 12 Do not use to exhaust hazardous or explosive vapors 13 Fans should always be vented to the exterior and in...

Страница 5: ...ance access at a location that will not interfere with installation work You may need the help of a second person to install this fan one person on the attic side and one on the room side Note Installations may vary depending on how the previous bath fan was installed Supplies necessary for the installation of your bath fan are not all included however most are available at your local home improve...

Страница 6: ...spension bracket I C and II D If spacing between joists is 21 5 in to 23 5 in attach suspension bracket III E 2 Position fan housing so edge of fan is flush with sheetrock Do not flush mount housing with joist 3 Secure the fan housing to joist with suspension brackets using long wood screws AA included Joist spacing of less than 21 25 in 4 Mounting with joist spacing of 21 25 in to 23 5in 1 C E D ...

Страница 7: ...hine screw BB included 6 Remove junction box cover As shown in wiring diagram on page 5 using quick connect ports connect house wires to switch and fan 7 Connect a 4 in circular duct and vent to the outside Secure it with duct tape or clamp Turn on power source EXISTING CONSTRUCTION ACCESSIBLE FROM ABOVE BEFORE INSTALLATION Turn off power source Review all safety precautions 1 Remove existing fan ...

Страница 8: ...ing 4 Insert suspension bracket onto fan housing using suspension bracket I C and II D If spacing between joists is 21 5 in to 23 5 in attach suspension bracket III E 5 Position fan housing so edge of fan is flush with sheetrock Do not flush mount housing with joist 6 Secure the fan housing to joist with suspension brackets using long wood screws AA included Joist spacing of less than 21 25 in 2 3...

Отзывы: