P
B
Assembly -Hanging the Fan (continued)
Making the electrical connections
12
WARNING:
To avoid possible electrical shock, ensure the
electricity is turned off at the circuit breaker or main fuse box
before wiring.
WARNING:
Check to see that all connections are tight,
including the ground, and that no bare wire is visible at the
wire nuts, except for the ground wire.
Motor to Receiver Electrical Connections:
Connect the WHITE wire from the fan to the WHITE wire marked
“Light N” from the Receiver.
Connect the BLUE wire from the fan to the BLUE wire marked
“Light L” from the Receiver.
Connect the YELLOW wire from the fan to the YELLOW wire
marked “MOTOR 1” from the Receiver.
Connect the RED wire from the fan to the RED wire marked
“MOTOR 2” from the Receiver.
Connect the GREY wire from the fan to the GREY wire marked
“MOTOR 3” from the Receiver
.
Receiver to House Supply Wires Electrical connections:
Connect the WHITE wire (Neutral) from the outlet box to the
WHITE wire marked ”AC in N” from the receiver.
Connect the BLACK wire (Hot) from the outlet box to the BLACK
wire marked “AC in L” from the receiver.
If your outlet box has a GROUND wire (Green or Bare
Copper),connect this wire to the Hanger Ball and Hanger
Bracket and receiver Ground wires.
If your outlet box does not have a Ground Wire, then connect the
Hanger Ball and Hanger Bracket and Receiver Ground Wire
together.
Secure wire connection with the plastic wire nuts (EE)
provided. Especially , for the ground wires, please use bigger wire
nut (EE) provided.
After all splices are made, check to make sure there are no
loose strands.
P
□
□
□
□
□
Outlet Box
Blue
Blue
White
White Yellow
Yellow
Red
Red Grey
Grey
Black
Black
Green
Green
White
White
Note: Fan must be installed from a maximum distance of 40 feet
(12.2 m) from the transmitting unit for proper signal transmission
between the transmitting unit and the fan’s receiving unit.
WARNING: To avoid possible electrical shock, ensure the
electricity is turned off at the main fuse box before wiring.
Insert the receiver (P) into the mounting bracket (B) with the flat
side of the receiver (P) facing the ceiling.
Follow the steps below to connect the fan to your house supply
wires. Secure the wire nuts supplied with your fan by wrapping the
connections with electrical tape.
Содержание BELFORD
Страница 1: ...Item XXX XXX Model SW1732 DAMP ORB BELFORD LED 52 INCH CEILING FAN FOR DAMP LOCATION ...
Страница 6: ......
Страница 11: ......
Страница 12: ...G OO OO 11 ...
Страница 14: ...14 Assembly Hanging the Fan continued 13 ...
Страница 15: ...15 Q S S Q 1 2 3 4 5 6 buttons PP PP QQ Learning process A23G 12V ...
Страница 16: ...R R Reverse function button QQ Controls the fan direction 16 ...
Страница 17: ...13 ...
Страница 19: ......