Safety Information 

 

WARNING:

 To reduce the risk of electrical shock or fire, do 

not use this fan with any solid-state fan speed control device.  
It will permanently damage the electronic circuitry.

WARNING:

 To reduce the risk of personal injury, do not 

bend the blade arms (also referred to as flanges), when 
installing the brackets, balancing the blades or cleaning the 
fan.

WARNING:

 Do not insert foreign objects between rotating 

fan blades.

WARNING:

 

To reduce the risk of fire, electric shock or 

personal injury, mount the fan to the outlet box marked 
acceptable for fan support with the screws provided with the 
outlet box.

CAUTION:

 To reduce the risk of personal injury, use only 

the screws provided with the outlet box.

3

HOMEDEPOT.COM/HOMEDECORATORS

Please contact 1-800-986-3460 for further assistance.

However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of 
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from   
   that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for  
   help.

1.     To reduce the risk of electric shock, ensure electricity has 

been turned off at the circuit breaker or fuse box before 
beginning.

2.     All wiring must be in accordance with the National Electrical 

Code “ANSI/NFPA 70-1999” and local electrical codes.  
Electrical installation should be performed by a qualified 
licensed electrician.

3.     The outlet box and support structure must be securely 

mounted and capable of reliably supporting a minimum of 35 
lbs (15.9 kg) or less. Use only UL-listed outlet boxes marked 
“FOR FAN SUPPORT.”

4.     The fan must be mounted with a minimum of 7 ft (2.1m) 

clearance from the trailing edge of the blades to the floor.

5.     Avoid placing objects in the path of the blades.

6.     To avoid personal injury or damage to the fan and other 

items, be cautious when working around or cleaning the fan.

7.     Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be 
suitable for most cleaning.

8.     After making electrical connections, spliced conductors 

should be turned upward and pushed carefully up into the 
outlet box. The wires should be spread apart with the 
grounded conductor and the equipment-grounding conductor 
on one side of the outlet box and ungrounded conductor on 
the other side of the outlet box.

9.     All setscrews must be checked and retightened where 

necessary before installation.

10.   This device complies with part 15 of the FCC Rules. Operation 

is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must 
accept any interference received, including interference that 
may cause undesired operation.

        Warning:  Changes or modifications to this unit not expressly 

approved by the party responsible for compliance could void 
the user's authority to operate the equipment.

        NOTE:  This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to Part 15 
of the FCC Rules.  These limits are designed to provide 
reasonable protection against harmful interference in a 
residential installation.  This equipment generates, uses and 
can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful 
interference to radio communications. 

The following responsible party designated in FCC §2.909 is 
responsible for this declaration:
Model Number:        YG618-NI,YG618-WH
Company Name:      TAL INTERNATIONAL CORPORATION 
Company Address:    2919 E. Philadelphia St., Ontario, CA 91761, U.S.A.
Full Name:               James Lai            Title:  Manager
Telephone Number: (909) 923-2888   Fax: (909) 923-8337

Содержание 1002 255 317

Страница 1: ...l Home Decorators Collection Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 800 986 3460 HOMEDEPOT COM HOMEDECORATORS THANK YOU THANK YOU Visual instruction of how to install this fan Visit www homedepot com and enter either the Item or Model number to find this fan and click the link of visual instruction in the product overview section ...

Страница 2: ...ns Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 9 10 11 15 16 Operation Pull Chain Operating Instructions Reverse Switch Operating Instructions Care and Cleaning Troubleshooting Service Parts 17 17 17 18 18 20 READ AND SAVE THESE INSTRUCTIONS ...

Страница 3: ... UL listed outlet boxes marked FOR FAN SUPPORT 4 The fan must be mounted with a minimum of 7 ft 2 1m clearance from the trailing edge of the blades to the floor 5 Avoid placing objects in the path of the blades 6 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 7 Do not use water or detergents when cleaning the fan or fan blades A dr...

Страница 4: ...cessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give the longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by un...

Страница 5: ...s pin preassembled Collar setscrew preassembled Collar mounting screw with lock washer preassembled Blade arm screw with lock washer preassembled Light kit mounting plate screw preassembled Light kit mounting screw preassembled Pull chain and fob Part Part Description Description 3 4 13 1 1 1 1 2 6 8 3 3 2 Quantity Quantity NOTE Hardware not shown to actual size 5 HOMEDEPOT COM HOMEDECORATORS Plea...

Страница 6: ...ntity 4 4 4 1 1 1 Part Part A B C D E F G Quantity Quantity 1 1 1 1 1 1 1 Description Description Mounting bracket preassembled Canopy ring preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover Fan motor assembly PACKAGE CONTENTS PACKAGE CONTENTS Pre Installation continued 6 H I J F K L M G A E B C D ...

Страница 7: ...dard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to the bottom of the fan blades to approximately 9 in Once you have decided which ceiling installation you will use refer to the corresponding sections and procedures during the assembly period Where necessary ea...

Страница 8: ...hree different ways to mount the outlet box NN not included NN NN OO NN NN A Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan s...

Страница 9: ...ger ball downrod assembly E Remove the ground lead QQ from the downrod assembly E Carefully feed the motor wires up through the downrod RR Thread the downrod RR into the collar Align the holes and replace the clevis pin DD and cotter pin EE Tighten the two collar setscrews HH Slip coupling cover F canopy ring B and canopy C onto the downrod RR Carefully reinstall the hanger ball PP onto the downro...

Страница 10: ... from the canopy C by loosening the four canopy mounting screws with lock washers BB on the top of the canopy C Remove the two non slotted canopy mounting screws with lock washers BB and loosen the slotted canopy mounting screws with lock washers BB Remove the canopy bottom cover D from the canopy C Make sure the slot openings of the canopy ring B are on top and then proceed to place the canopy ri...

Страница 11: ...ing system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of the hanger ball E Failure to properly seat the tab in the groove could cause damage to the wiring WARNING The hook is only to hold the fan while attaching wiring Failure to hang as instructed may result in the tab breaking causing the fan to f...

Страница 12: ...e fan to your household wiring Use the plastic wire nuts AA with your fan Secure the plastic wire nuts AA with electrical tape Make sure there are no loose strands or connections Make wire connections as follows using the wire nuts AA From Fan To Outlet Box Black Blue Wires Black Wire Hot White Wire White Wire Neutral Green Wires Green or Bare Wire Ground There are two green grounding leads one fr...

Страница 13: ... or off separately Make wire connections as follows using the wire nuts AA Wall switch not included From Fan To Outlet Box Black Blue Wires Black Wire Hot White Wire White Wire Neutral Green Wires Green or Bare Wire Ground From Fan To Outlet Box Black Wire for Fan Black Wire Hot 1 Blue Wire for Light Red Wire Hot 2 White Wire White Wire Neutral Green Wires Green or Bare Wire Ground AA SINGLE SWITC...

Страница 14: ...are provided only as an aid to mounting Do not leave the fan assembly unattended until all four canopy mounting screws with lock washers BB are engaged and firmly tightened Slide the canopy C up to the ceiling Make sure you have placed the wires safely into the outlet box NN Secure the canopy C to the mounting bracket A with the four canopy mounting screws with lock washers BB included with your f...

Страница 15: ...re the blade I is straight Repeat these steps for the remaining blades Align the holes from the blade arm H to the holes from the motor G and secure the blade arm in place with screws and washers JJ provided Repeat this process to attach the other blades assemblies Assembly Attaching the Fan Blades 10 Fastening the blade assemblies to the motor 9 Attaching the blades to the blade arms 8 Removing t...

Страница 16: ...uit breaker or removing the fuse at the fuse box Turning power off using the fan switch is not sufficient to prevent electric shock Remove one of the three light kit mounting screws LL from the light kit mounting plate K and loosen the other two screws LL Do not remove While holding the 18W LED light kit L under the fan motor assembly G snap together the wire connection plugs UU Place the key hole...

Страница 17: ...Wait for the fan to stop before reversing the direction of the blade rotation REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing Slide the switch to the left for warm weather operation Slide the switch to the right for cool weather operation Warm weather Counterclockwise Direction A downward air flow create...

Страница 18: ...e power is off at the electrical panel box before you attempt any repairs Refer to step 6 Making the Electrical Connections on page 12 Problem Problem Solution Solution Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan b...

Страница 19: ... select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and repeat the measurement using the same point from the ceiling for every blade Measurement deviations should be within 1 8 in If all deviations are less than 1 8 in and the fan continues to wobble please call Customer Service 1 800 986 3460 to orde...

Страница 20: ... preassembled Blade arm screw with lock washer preassembled Light kit mounting plate screw preassembled Light kit mounting screw preassembled Pull chain and fob Service Parts Part Part A B C D E F G H I J K L M Description Description Mounting bracket preassembled Canopy ring preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Coupling cover Fan motor assembly Blade a...

Страница 21: ...ssing parts Before returning to the store call Home Decorators Collection Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 800 986 3460 HOMEDEPOT COM HOMEDECORATORS Retain this manual for future use ...