SEASONAL START UP
Prior to starting the first fire of the heating season, check the outside area around the exhaust systems for
obstructions. Clean and remove any fly ash from the exhaust venting system. Clean any screens on the exhaust
system and on the outside air intake pipe. This is also a good time to give the entire appliance a good cleaning
throughout.
SEASONAL SHUTDOWN
The exhaust system should be thoroughly cleaned. REMOVE ANY ASH OR UNBURNED WOOD.
MAINTENANCE SCHEDULE
Use the following as a guide under average use conditions.
Gaskets around door and door glass should be inspected and repaired or replaced when necessary.
Daily
Weekly
Monthly or as needed
Ashes
Check
Empty
Vent System
Cleaned
When your appliance acts out of the ordinary, the first reaction is to call for help. This guide may save time and
money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five
factors.
1. Poor fuel;
2.
Poor operation or maintenance;
3. Poor installation;
4. Component failure;
5.
Factory defect.
You can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5.
Refer to the repair parts diagrams to help locate indicated parts.
Never try to repair or replace any part of the appliance unless instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Trouble Shooting Guide
Optional Brick Kit
4
5
3
1
2
Key Part No
Description
Qty
1
28078
Rear Brick Retainer
1
2
28072
Side Brick Retainer
2
3
89066A
Firebrick (4-1/2 x 9) Pumice
32
4
892779A Quarter Firebrick (2-1/4 x 9) Pumice
1
5
891414A Half Firebrick 1-1/4 x 2-1/4 x 9 Pumice
2