Homa Sanistar 105D Скачать руководство пользователя страница 28

28 | EngliSH

6. Maintenance

6.1. General

The entire system must be checked and serviced at 
regular intervals.

The following points should be noted:

• 

The operating and maintenance manual must be 
available to the maintenance personnel and its 

 

instructions followed. Only the repair and mainte-
nance measures listed here may be performed.

• 

All maintenance, inspection and cleaning work on the 
machine and the system may only be carried out by 
trained specialists exercising extreme care in a safe 
workplace. Proper protective clothing is to be worn. 
The machine must be disconnected from the electric-
ity supply before any work is carried out. There must 
be no way that it can be inadvertently switched on. 
Additionally, the appropriate protective measures as 
defined by the BGV/GNV should be enforced when 
working in basins and/or containers.

• 

Ensure that the necessary tools and materials are 
available. Order and cleanliness guarantee safe and 
trouble-free work on the machine. Remove used 
cleaning materials and tools from the machine after 
completing the work. Keep all materials and tools in 
their designated places.

• 

Operating supplies such as oil and lubricants must 
be collected in appropriate vessels and properly dis-
posed of (in accordance with the 75/439/EEC direc-
tive and with §§5a, 5b AbfG). Appropriate protective 
clothing is to be worn for cleaning and maintenance 
jobs. This is to be disposed of in accordance with 
waste code TA 524 02 and EC Directive 91/689/EEC. 
Only lubricants expressly recommended by the man-
ufacturer may be used. Oils and lubricants should 
not be mixed. Only use genuine parts made by the  
manufacturer.

A trial run or functional test of the plant must only be 
carried out under the general operating conditions!

6.2. Maintenance dates

Monthly:

• 

Checking current consumption and voltage

Semi-annually:

• 

Visual inspection of the power supply cable

6.3. Maintenance work

checking current consumption and voltage

Current consumption and voltage on all 3 phases are to be 
checked regularly. In normal operation, these remain con-
stant. Slight fluctuations depend on the nature of the con-
veyed medium. Observing current consumption enables 
damage and/or malfunctions of blade wheel/propeller, 
bearings and/or motor to be detected and resolved at an 
early stage. This can largely prevent greater consequential 
damage and reduce the risk of a total failure.

Visual inspection of the power supply cable

The power supply cable must be examined for bubbles, 
cracks, scratches, abrasions and / or pinching points. 
Upon detection of damage, the damaged power supply 
cord must be replaced immediately.

The cable may only be replaced by the manufactur-
er or an authorized or certified service workshop. The 
machine may not be put into operation again until the 
damage has been properly fixed!

7. Troubleshooting

The following points must be taken into account to avoid 
personal and material damage when troubleshooting 

 

machine failures:

• 

Correct a failure only if you have qualified staff, i.e. 
the individual work must be carried out by trained 
specialist personnel, e.g. electrical work must be  
carried out by a qualified electrician.

• 

Always prevent the machine from unintentional 
restart by disconnection it from the power supply. 
Take appropriate precautionary measures.

• 

Ensure the safety shut-down of the machinery by a 
second person at all times.

• 

Safeguard mobile machinery parts to prevent injuries.

• 

Unauthorized changes on the machinery are at own 
risk and discharge the manufacturer from any liability!

Further steps for troubleshooting

If the aforementioned points do not help you to eliminate 
the fault, contact our customer service. They can help you 
as follows:

• 

Assistance by telephone or in writing by the 

 

customer service

• 

Support on site by the customer service

• 

Check/repair of the machinery in the factory

Please note that the use of certain services of our custo-
mer service might incur further costs! Please contact our 
customer service for further information.

Содержание Sanistar 105D

Страница 1: ...Original Betriebsanleitung EN Original Instruction Manual NL Originele handleiding Sanistar Sanistar Plus...

Страница 2: ...Sicherheits und berwachungseinrichtungen 06 2 8 F rdermedien 06 2 9 Schalldruck 06 3 Allgemeine Beschreibung 07 3 1 Verwendung 07 3 2 Einsatzarten 07 3 3 Aufbau 07 4 Verpackung Transport und Lagerung...

Страница 3: ...fabrik GmbH Diese Betriebsanlei tung ist f r das Bedienungs Montage und Wartungsper sonal bestimmt Sie enth lt Vorschriften und Zeichnungen technischer Art die weder vollst ndig noch teilweise ver vie...

Страница 4: ...n Insbesondere solche auf Minderung Wandlung oder Schadenersatz auch f r Folgesch den jeglicher Art Um eine z gige Bearbeitung im Garantiefall zu gew hr leisten kontaktieren Sie uns oder den f r sie z...

Страница 5: ...kom men sein Der Bediener hat jede auftretende St rung oder Unregelm igkeit sofort seinem Verantwortlichen zu mel den Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich wenn M ng...

Страница 6: ...llstand kommen lassen 2 7 Sicherheits und berwachungseinrichtungen Unsere Anlagen sind mit verschiedenen Sicherheits und berwachungseinrichtungen ausgestattet Diese Einrich tungen d rfen nicht demonti...

Страница 7: ...Einsatzarten Die Abwasser Hebeanlage ist f r den Aussetzbetrieb S3 40 ausgelegt 3 3 Aufbau Die Abwasser Hebeanlagen bestehen aus einem unver rottbaren wasser gas und geruchsdichten Kunststoff beh lter...

Страница 8: ...30 l 45 l 30 l 45 l zul ssige Mediumtemperatur 35 C 35 C 35 C 35 C 35 C 35 C 35 C freier Durchgang 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm max L rmpegel 63 65dBA 63 65dBA 63 65dBA 63 65dBA 63 65dBA...

Страница 9: ...kann Ihr Produkt ber einen l ngeren Zeitraum eingelagert werden Beachten Sie aber dass die Elastomerteile und die Beschichtungen einer nat rlichen Verspr dung unterliegen 4 4 R cklieferung Produkte d...

Страница 10: ...die R ckstauebene gef hrt wer den d h sie muss stetig steigend ber dieses Niveau und anschlie end in einer Schleife direkt zur Sammelleitung gef hrt werden Unmittelbar nach der integrierten R ckschlag...

Страница 11: ...afo Fehlerstrom oder Fehlerspan nungsschutzschalter m ssen den Vorschriften des zust ndigen Elektrizit tswerkes entsprechen Die in den Technischen Daten angegebene Spannung muss der vorhandenen Netzsp...

Страница 12: ...ellt Bitte informieren Sie Ihren Kundendienst HOMA ServCom Contoller zum Programmieren und Abru fen von Betriebsdaten als Zubeh r erh ltlich 5 5 2 Elektronik Steuerger t PS H f r Sanistar Sanistar Plu...

Страница 13: ...tung auf Bei falscher Drehrichtung sind 2 Phasen des Netzanschlus ses zu vertauschen Die Pumpen werden serienm ig mit CEE Netzstecker geliefert Die Phasenvertauschung er folgt durch 180 Drehung der ru...

Страница 14: ...elm ig zu kontrollieren Bei normalem Betrieb bleibt diese konstant Leichte Schwankungen sind von der Bes chaffenheit des F rdermediums abh ngig Anhand der Stromaufnahme k nnen Besch digungen und oder...

Страница 15: ...schen Pumpe saugt sich am flexiblem Boden fest Stellen sie die Pumpe auf einen festen Untergrund Maschine l uft die angegebenen Betriebswerte werden nicht eingehalten Ursache Abhilfe Zulauf verstopft...

Страница 16: ...fluids 20 2 9 Sound Pressure 21 3 General Description 21 3 1 Utilization 21 3 2 Type of application 21 3 3 Structure 21 4 Packaging Transport and Storage 23 4 1 Delivery 23 4 2 Transport 23 4 3 Storag...

Страница 17: ...y not be reproduced or distributed either completely or in part or used for any other purpose without the expressed consent of the man ufacturer 1 5 Warranty Costs for removal and installation of the...

Страница 18: ...e not superseded by the information in this chapter The manufacturer is obliged to correct any defects found in the products it sells provided that the following require ments have been fulfilled The...

Страница 19: ...ical current Incorrectly performed electrical work can result in fatal injury This work may only be carried out by a qualified electrician 2 Safety This chapter lists all the generally applicable safe...

Страница 20: ...k 2 7 Safety and control devices Our products are equipped with various safety and con trol devices These devices must never be dismantled or disabled Equipment must be checked by an electrician for p...

Страница 21: ...ections Container connections Sanistar 1 Sanistar 2 Discharge Flange DN 80 EU piece DN 80 DN 100 Inlet inlet height DN 100 horizontal 180 mm DN 100 horizontal 250 mm DN 150 horizontal 210 mm DN 100 DN...

Страница 22: ...30 l 45 l 30 l 45 l Permitted medium temperature 35 C 35 C 35 C 35 C 35 C 35 C 35 C Spherical clearance 45 mm 45 mm 40 mm 45 mm 45 mm 45 mm 45 mm max noise level 63 65dBA 63 65dBA 67 68dBA 63 65dBA 63...

Страница 23: ...d of time However note that the elastomer parts and coatings are subject to natural em brittlement 4 4 Materials returned Products that are returned to the factory must be clean and correctly packaged...

Страница 24: ...ise above this level and must then feed directly to the manifold in a loop A gate valve should be installed immediately after the integrated non return flap in the discharge line In order for the leve...

Страница 25: ...correspond to the available mains voltage Make sure that the electrical connections are in a flood safe area and are protected from moisture The power cord and plug must be checked for damage before u...

Страница 26: ...ing functions Operating limit switch MANUAL setting The respective pump operates permanently indepen dent of the contents of the container For this setting the switch must be held in place manually Wh...

Страница 27: ...power supply must be interchanged As standard the pumps are delivered with CEE power plugs The in terchange of phases is carried out by 180 rotation of the round holding plate on the poles of the plug...

Страница 28: ...k Checking current consumption and voltage Current consumption and voltage on all 3 phases are to be checked regularly In normal operation these remain con stant Slight fluctuations depend on the natu...

Страница 29: ...exible ground Move the pump on hard ground The machinery is running the indicated operating values are not met Cause Remedy Inlet obstructed Clean inlet gate valve suction piece suction branch suction...

Страница 30: ...ewakingscontroles 34 2 8 Vloeistoffen 34 2 9 Geluidsdruk 35 3 Algemene beschrijving 35 3 1 Toepassing 35 3 2 Toepassingswijzen 35 3 3 Opbouw 35 4 Verpakking transport en opslag 37 4 1 Aanlevering 37 4...

Страница 31: ...andleiding is in handen van HOMA Pumpenfabrik GmbH Deze handleiding is bedoeld voor het bedienings montage en onderhoudspersoneel De handleiding omvat voorschriften en tekeningen van technische aard d...

Страница 32: ...jn speciaal voor onze producten ontwikkeld Eigenmachtige aan en ombouwwerkzaamheden of de toepassing van andere dan originele onderdelen kunnen leiden tot ernsti ge schade aan het product en of tot er...

Страница 33: ...men De technische instructies moeten strikt worden opgevolgd Wanneer een machine is uitgeschakeld door een beveili ging mag deze pas weer worden ingeschakeld nadat de fout is verholpen 2 Veiligheid In...

Страница 34: ...onderdelen niet aan Schakel de machine v r onderhouds of reparatiewerkzaamheden uit en laat de draaiende onderdelen tot stilstand komen 2 7 Veiligheids en bewakingscontroles Onze installaties zijn uit...

Страница 35: ...wijzen De vuilwater opvoerinstallatie is ontworpen voor intermit terend bedrijf S3 40 3 3 Opbouw De afvalwater opvoerinstallaties bestaan uit een niet rottend water gas en geurdicht kunststof reservoi...

Страница 36: ...45 l 30 l 45 l Toegestane mediumtemperatuur 35 C 35 C 35 C 35 C 35 C 35 C 35 C vrije doorlaat 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm 45 mm max Geluidsniveau 63 65 dBA 63 65 dBA 63 65 dBA 63 65 dBA 63 65...

Страница 37: ...d er echter rekening mee dat de elastomere delen en de coatings onderhevig zijn aan een natuurlijke verbrossing 4 4 Retourneren Producten die worden teruggestuurd naar de fabriek moeten schoon en corr...

Страница 38: ...s stijgend tot boven dit niveau en vervolgens in een lus direct naar de verzamelleiding moet worden geleid Direct na de ge ntegreerde terugslagklep moet in de persleiding een schuifafsluiter worden ge...

Страница 39: ...aanwezig zijn Aarding aarding van de neutrale lei ding scheidingstransformator en aardlekschakelaar moeten voldoen aan de voorschriften van het verant woordelijke elektriciteitsbedrijf De in de Techn...

Страница 40: ...Com controller voor het programmeren en op roepen van bedrijfsgegevens als toebehoren verkrijgbaar 5 5 2 Elektronica besturingskast Sanistar Sanistar Plus dubbele installatie Het bij de levering van d...

Страница 41: ...raairichting op Bij verkeerde draairichting moeten 2 fasen van de netaansluiting wor den omgewisseld De pompen worden standaard met CEE netstekker geleverd De faseverwisseling vindt plaats door de ron...

Страница 42: ...op alle drie de fasen moet regelmatig worden gecontroleerd Bij normaal be drijf blijven deze constant Lichte schommelingen zijn afhankelijk van de eigenschappen van de vloeistof Aan de hand van het st...

Страница 43: ...an flexibele bodem vast Plaats de pomp op een stevige vlakke ondergrond Machine draait maar de opgegeven bedrijfswaarden worden niet aangehouden Oorzaak Oplossing Toevoer verstopt Toevoerleiding afslu...

Страница 44: ...N 100 Horizontale toevoer DN 100 3 Horizontaler Zulauf DN 150 Horizontal inlet DN 150 Horizontale toevoer DN 150 4 Vertikaler Zulauf DN 100 DN 40 Vertical inlet DN 100 DN 40 Verticale toevoer DN 100 D...

Страница 45: ...tungsstutzen DN 70 Air vent DN 70 Ontluchtingsaansluting DN 70 8 Reinigungs ffnung Cleaning cover Reinigingsopening 9 Kugel R ckflussverhinderer DN 80 Soft ball check valve DN 80 Kogel terugslagklep D...

Страница 46: ...einigungs ffnung Cleaning cover Reinigingsopening 7 Kugel R ckflussverhinderer DN 80 Soft ball check valve DN 80 Kogel terugslagklep DN 80 8 Elastisches bergangsst ck Elastic union piece Elastisch ove...

Страница 47: ...ep DN 80 8 Elastisches bergangsst ck Elastic union piece Elastisch overgangsstuk 9 Keilflachschieber DN 80 bauseits Flanged gate valve DN accessory Vlakke wigschuif DN 80 niet inbegrepen 10 Anschluss...

Страница 48: ...48 Notizen Notes...

Страница 49: ...edingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonst...

Страница 50: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bi...

Страница 51: ...tourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioa...

Страница 52: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Отзывы: