2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 

2.2. General Safety Precautions

 

General regulations and guidelines not mentioned in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions 
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept 
available at the operating place of the machine/unit at all 
times. Persons who are not familiar with the operating in-
structions shall not use this product. 

Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.

 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Always use personal safety equipment such as safety 

boots, rubber gloves, safety glasses and helmet. 

Make sure that the emergency exit from the workplace 

is not barricaded. 

To prevent suffocation and poisoning caused by ven-

omous gases, make sure that enough oxygen exists at the 
workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third par-

ties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 
 

 
 
 
 
 
 

3. Applications and Technical Description 

3.1. Applications 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is self-assured by a 30 mA earth leakage circuit 
breaker. 
TP 50, TP 53 and TP 70 pumps are designed for pumping 
waste water, or groundwater, containing sludge or soft sol-
ids.  
The pumps are used for installations in public and private 
sector, trade and industry. 
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or 
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be 
checked. 
The pumps may be used for both temporary or permanent 
installation. The installation can be free-standing on a 
base-stand or by means of an auto-coupling guide rail  
system (available as accessory). 

3.2. Technical Data 

Discharge  
TP 50 

BSP 2 ½“ M 

TP 53 

BSP 3“ M 

TP 70 M...up 1,8 kW (P

2

BSP 3“ M 

TP 70 M...to 1,9 kW (P

2

) DN 

80 

TP 70 

BSP 3“ M 

Voltage  
1Ph-Motor (Model W) 

230 V 

3Ph-Motor (Model D) 

400 V 

Speed  
TP 50, TP 53 

2900 rpm 

TP 50, TP 53 M 12, M 13 V 13 

1450 rpm 

TP 70 

1450 rpm 

TP 70 V 31, …V 36,…V50 

2900 rpm 

Insulation class 

Motor protection 

IP 68 

Cable 10 

Cable type 

H 07RN-F... 

Noise level during operation, 1,60 m from the 
ground 

 70d(B)A 

 

Information for the operation on a frequency 
converter: 

As a minimum, properly sized load reactors and filters 
must be installed between the inverter and the pump to 
protect the pump motor from damaging voltage spikes. 
Warranty coverage will not be provided on any pump mo-
tor that is operated with a variable frequency drive, unless 
the load side of the inverter is properly isolated from the 
pump. 

 
3.3. Operating Conditions 
Maximum liquid temperature:

 35°C, short term up to 

60°C. 

Density of pumped liquid:

 max. 1100 kg/m

3

 

Ph-value of pumped liquid:

 5 up to 11. 

Level of pumped liquid:

 The lowest level must always be 

above the top of the pump housing (volute). 

Operation:

 The motors are designed for continuous op-

eration (S1) with fully submerged motor, maximum 15 
starts per hour. Our standard warranty and maintenance 
regulations refer to intermittent operation. For reduced 
warranty periods and service intervals due to continuous 
operating conditions please contact our service 
department. 

 

Содержание CTP 50 M

Страница 1: ...ng Original Instruction Manual Origineel Bedrijfsinstructies Original Manuel d instructions de montage HOMA Pumpenfabrik GmbH 02 2011 Industriestr 1 D 53819 Neunkirchen Seelscheid Baureihe Series Serie Séries TP 50 TP 53 TP 70 ...

Страница 2: ...e 37 Page 37 Pagina 38 Page 38 DEUTSCH ENGLISH NEDERLANDS FRANÇAIS Elektroanschluss Electrical connection Raccordement électrique Baumaße Dimensions Afmetingen Encombrements Ersatzteilliste und Ersatzteilzeichnungen Spare part list and spare part drawings Onderdelenlijst en onderdelentekeningen Liste de pièces détachées et coupes ...

Страница 3: ...t dass die Pumpen vom Typ TP 50 TP 53 TP 70 aufgrund ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausführung den einschlägigen grundlegenden Sicherheits und Gesundheitsanforderungen der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimmten Änderung der Pumpen verliert diese Erklärung Ihre Gültigkeit EG Richtlinien denen die Pumpen entsprechen EG Masch...

Страница 4: ...isen darauf hin dass wir nach dem Produkthaf tungsgesetz für Schäden die durch unser Gerät verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften Für Zubehörteile gelten die gleichen Be stimmungen 3 Einsatz und Technische Beschreibung 3 1 Einsatz der Pumpen Beim Einsatz der Pumpen zur Reinigung bzw War tungen in Schwimmbecken ist ...

Страница 5: ...as Ende des Anschlusskabels darf nicht ins Wasser eingetaucht werden da sonst Wasser in den Motor Anschlussraum gelangen kann Motorschutzschalter bzw Schaltgeräte dürfen niemals in explosionsgefährdeten Bereichen montiert werden Vorschrift für Österreich Bei Verwendung in Schwimmbecken und Gartenteichen darf die Pumpe nur über einen Trenntransformator gemäß ÖVE EM 42 Teil 2 2000 1974 2022 betriebe...

Страница 6: ...ls Die Ansprechempfindlichkeit sollte von 0 100 kΩ einstell bar sein Standardeinstellung 50 kΩ Bei Ex Ausführung Elektrodenrelais mit eigensicherm Stromkreis für Sensoren wählen 6 5 Drehrichtungskontrolle Wechselstrom Bei 1Ph Motoren ist eine Kontrolle der Drehrichtung nicht notwendig da sie immer mit der korrekten Drehrichtung laufen Drehstrom Alle Pumpen haben die richtige Drehrichtung bei Ansch...

Страница 7: ... Sie bitte die nachstehenden Hinweise Die Befestigungspunkte sowie die Länge des frei bewegli chen Endes des Schwimmerkabels sind auf das ge wünschte Schaltniveau einzustellen Dabei ist zu beach ten dass der Einschaltpunkt der Pumpe unterhalb der Zu laufleitung liegt um einen Rückstau des Fördermediums zu vermeiden Der Ausschaltpunkt muss oberhalb der Saugöffnung lie gen damit sich kein Luftpolste...

Страница 8: ...unseren Werkskundendienst Rücksendung Wurde die Pumpe für die Förderung einer gesundheitsschädlichen oder giftigen Flüssigkeit eingesetzt wird die Pumpe als kontaminiert klassifiziert In diesem Fall müssen bei jeder Serviceanforderung detaillierte Informationen über das Fördermedium vorliegen Bei eventueller Serviceanforderung muss unbedingt vor dem Versand der Pumpe mit HOMA Kontakt aufgenommen w...

Страница 9: ...lingen 03 31 740 40 70 0 74 31 95 83 24 Naumann Pumpen GmbH Co KG G Meier GmbH Am Wall 11 Gustav Schwab Str 16 14979 Großbeeren 72762 Reutlingen 03 37 01 52 50 0 71 21 26 90 0 HEKO Pumpen GmbH Pumpen Zeyer Meiendorfer Straße 71 Maybachstraße 25 22145 Hamburg 74076 Heilbronn 0 40 6 91 90 90 0 71 31 67 78 44 Karl Heinz Birr Pumpenservice Elmar GmbH Glashüttenweg 60 Wertstraße 48 23568 Lübeck 73240 W...

Страница 10: ...fabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and construction the following pump types in the form in which they are marketed by us conform to the relevant fundamental safety and health re quirements of the EC Machine Directives TP 50 TP 53 TP 70 EC Directives to which the pumps conform EC Machinery Directive 2006 42 EEC EC Directive ...

Страница 11: ...es set forth in the operating instructions The same product liability are valid for accessories 3 Applications and Technical Description 3 1 Applications If the pump is used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during operation of the pump and that the pump is self assured by a 30 mA earth leakage circuit breaker TP 50 TP 53 and TP 70 pu...

Страница 12: ...the nominal current consumption of the pump motor see data on pump label For capacitor sizes see table below Pump type Operating capacitor μF VAC TP 50 TP 53 2pole up to 0 8 kW P2 25 450 TP 50 TP 53 2pole above 1 0 kW P2 30 450 TP 50 TP 53 4pole up to 0 9 kW P2 40 450 TP 70 up 1 1 kW P2 40 450 6 2 Connection of 3 Ph Motors TP 50 TP 53 and TP 70 pumps with 3Ph motors are sup plied with or must be c...

Страница 13: ...180 turning of the small round pole socket at the plug end with a screwdriver 7 Installation Pay attention to the maximum depth of immersion see pump label If the pump is installed in a sump the sump opening must be covered with a tread safe cover after installation The operator has to prevent damage through the flooding of rooms caused by defects of the pump through the use of appropriate measure...

Страница 14: ...turer or through an authorized workshop Conversions or alternations of the machine unit are permittes only after arrangement with the manufac turer Only HOMA spare parts shall be used In accordance with the product liability law we point out that we shall not be liable for damages caused by our product due to unauthorized repair by persons other than the manufacturer or an authorized workshop or d...

Страница 15: ...trips out after a short while Low setting of thermal relay in motor starter Set the relay in ac cordance with the specifications on the pump label Increased current consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 10 5 for ex plosion proof pumps Impeller blocked by impurities Increased current consumption in all three phases Clean the impeller Pump opera...

Страница 16: ...eid verklaren hiermee dat de pomp typen TP 50 TP 53 TP 70 Op grond van hun concipiёring en bouwwijze als ook in de door ons in verkeer gebrachte uitvoering aan de desbetreffende fundamentele veiligheids en gezondheidseisen van de EG machinerichtlijnen voldoen Bij een niet met ons afgestemde verandering aan de pompen verliest deze verklaring haar geldigheid EG Richtlijnen waaraan de pompen voldoen ...

Страница 17: ...schade welke door onze machines veroorzaakt worden wanneer de aanwijzingen en voorschriften uit deze gebruiksaanwijzing niet in acht genomen worden Voor toebehoren gelden dezelfde regels 3 Inzetbaarheid en technische beschrijving 3 1 Toepassing van de pompen Bij inzet van pompen voor reiniging of onderhoud in zwembaden moet men zekerstellen dat er zich geen personen in het te verpompen medium bevi...

Страница 18: ... TP 70 pompen met 230 V 1Ph Motoren moeten aan een schakelkast met Motorbeveiligings schakelaar en bedrijfscondensator aangesloten worden Originele Homa schakelkasten zijn als toebehoor leverbaar z Schakelkasten programma Bij toepassing van andere schakelkasten dient men voor de keuze van de motorbeveiligingschakelaar de nennstroom van de pompmotor in acht te nemen Voor de noodzakelijke condensato...

Страница 19: ... de start ruk plaatsvinden De draairichting is met de klok mee gezien vanaf de bovenzijde van de pomp Tijdens het starten zal de pomp echter even in tegengestelde richting roteren Bij grotere pompen dient de draairichting door een testloop voor inbouw vastgesteld te worden Bij vast geϊnstalleerde pompen kan in noodgeval de opvoerhoogte op capaciteit bij verschillende draairichtingen vergeleken wor...

Страница 20: ... worden daar correcte schakeling alleen door een scharnierbeweging van de ni veauschakelaar op het bevestigingspunt van de kabel mogelijk is Mogelijke gevolgen wanneer u dit niet in acht neemt zijn o a overstromingen pomp schakelt niet in en storing aan de pomp door droogloop pomp schakelt zich niet uit Bij gebruik van aparte niveauschakelaars voor pomp start pomp stop en alarm zijn de schakelnive...

Страница 21: ...en Eventuele kosten voor het retourneren van de pomp zijn voor rekening van de klant Indien de pomp is gebruikt voor vloeistoffen die schadelijk zijn voor de gezondheid dient de aanvraag voor een servicebeurt te allen tijde vergezeld te gaan van gegevens over het gepompte medium 10 Opsporen van storingen Voor elke reparatie aan pomp stroomtoevoer uitscha kelen Storing Oorzaak Oplossing Motor start...

Страница 22: ...ndustriestrasse 1 D 53819 Neunkirchen Seelscheid certifions que les pompes spécifiées ci dessous TP 50 TP 53 TP 70 correspondent aux exigences en matière d hygiène et de sécurité de la directive machine CE Toute transformation de la pompe non autorisée entraîne la nullité de la présente déclaration Directives CE auxquelles les pompes correspondent Directive machine 2006 42 EG Directive compatibili...

Страница 23: ...gnes s appliquent aussi aux accessoires 3 Utilisation et caractéristiques techniques 3 1 Limites d utilisation des pompes Si les pompes sont utilisées pour le nettoyage entretien d une piscine s assurer que personne ne se trouve dans le liquide refoulé et que les pompes sont alimentées par un dispositif de protection différentielle d une sensibilité au plus égale à 30 mA Les pompes de la gamme TP ...

Страница 24: ...l eau pour exclure tout risque d infiltration d eau dans le boîtier de raccordement du moteur Le disjoncteur moteur et les coffrets de commande ne doivent pas être installés dans des zones présentant un risque d explosion 6 1 Raccordement moteurs monophasés W et WA Les pompes de la gamme TP 50 TP 53 et TP 70 équipées de moteurs 230 V monophasés sont dotés de série d un coffret de commande avec dis...

Страница 25: ...t La sensibilité doit être réglable de 0 100 kΩ réglage par défaut 50 kΩ 6 5 Contrôle du sens de rotation Les moteurs monophasés ne nécessitent pas de contrôle du sens de rotation car ils tournent toujours dans le bon sens Les moteurs triphasés en revanche doivent subir un contrôle du sens de rotation avant la mise en service Si la pompe fonctionne avec un coffret de commande HOMA avec affichage d...

Страница 26: ...nnement sans problème suivre les consignes ci dessous Régler les points de fixation ainsi que la longueur de l extrémité libre du câble du flotteur par rapport à la course souhaitée Attention le point de démarrage de la pompe doit être plus bas que le tuyau d arrivée pour éviter toute possibilité de reflux du liquide pompé Le point d arrêt doit être plus haut que l ouverture d aspiration pour évit...

Страница 27: ...Pour toute intervention de service après vente par HOMA il faut contacter la société en fournissant des détails sur le liquide pompé etc avant de retourner la pompe Dans le cas contraire HOMA peut refuser la pompe dans son service aprèsvente Les frais de réexpédition de la pompe restent à la charge du client Dans toute démarche de service après vente quel que soit l endroit il faut toujours précis...

Страница 28: ...ons sensor Dichtingscontrole Abb 2 Fig 2 Ex Ausführung Model Ex Ex Uitvoering Modèle anti déflagrant T1 T2 Temperaturfühler Begrenzer ca 140 C Temperature sensors Limitator approx 140 C Temperatuurvoeler Limitator ca 140 C Sondes de température S1 S2 Dichtungsüberwachung Ölkammer Oil chamber seal conditions sensor Dichtingsbewaking Abb 2 Fig 2 Anschlussdiagramm Standardmotor Stern Dreieck Start vo...

Страница 29: ...tment F1 Nominal current x 0 58 Motorbeveiliging instelling F1 nominaalstroom x 0 58 Abb 6 Fig 6 Netzanschluss Direkt Start DOL für Stern Dreieck Vorbereitet Motor alle Wicklungen über Anschluss kabel zugänglich Dreieckschaltung der Wicklung Starter connection Direct on line Start for Star Delta Start prepared motors Delta connection of stator windings Netaansluiting direct start DOL voor ster dri...

Страница 30: ...1 M14 450 160 231 110 R 3 AG BSP 3 M 50 271 25 111 V17 2W 465 160 231 124 R 3 AG BSP 3 M 65 271 25 111 M12 4W M13 M23 M26 V26 V13 518 177 212 101 R 3 AG BSP 3 M R 50 287 25 110 M37 V40 555 177 232 101 R 3 AG BSP 3 M 50 287 25 110 M50 V50 593 177 232 101 R 3 AG 50 287 25 110 TP 70 M 13 TP 70 M 16 TP 70 V TP 70 A B C D E F G H I M13 M16 V 16 V15 586 160 258 180 R 3 AG BSP 3 M 90 320 25 125 V31 V36 6...

Страница 31: ...ed Installation with auto coupling Installatie met automatische koppeling Installation immergée avec kit d accouplement Einzelstation Single station Enkel pompstation Station 1 pompes Doppelstation Double station Dubbel pompstation Sta tion 2 pompes An ...

Страница 32: ...3 1 231 1 V17 2W 465 131 66 629 335 170 DN 80 1 1 2 ISO 87 446 625 8001 625 800 1 1000 1500 1 231 689 1 485 1 113 190 165 165 180 260 453 1 231 1 M12 4W M13 M23 M26 V26 V13 518 139 89 645 335 170 DN 80 1 1 2 ISO 87 462 625 800 1 625 800 1 1000 1500 1 232 690 1 485 1 113 190 165 165 180 260 453 1 231 1 M37 V40 555 139 89 645 335 170 DN 80 1 1 2 ISO 87 462 625 800 1 625 800 1 1000 1500 1 232 690 1 4...

Страница 33: ...s Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 14 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Year of construction see pump label Part details 1 Pos no Part description Required Quantity 2 Pos no Part description Required Quantity 3 Pos no Part description Required Quantity 4 Pos no Part descr...

Страница 34: ...Afleveringsadres Handtekening Firmastempel 14 formulaire de commande de pièces de rechange A HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid Fax 49 2247 70244 Type de pompe voir plaque de pompe Année de construction voir plaque Détail des pièces 1 Rep n Désignation de la pièce Quantité désirée 2 Rep n Désignation de la pièce Quantité désirée 3 Rep n Désignation de la pièce...

Страница 35: ...au bung 999 xx Ersatzteile für Schaltge rät 722 Anschlussstutzen 15 Spare part list and drawings 15 1 Spare part list ATTENTION The following list contains parts that do not correspond to every pump type For spare part orders please always give Pump type The year of construction see the pump label Position number xx take the exact position number from the drawing of the specific pump model see her...

Страница 36: ...ng 719 Krimpslang 970 Typeplaat 720 Aansluitknie 990xx Motorolie 721 STA 3 delige slang kopp 999xx Onderdelen voor schakel kast 722 Aansluitring 15 Liste de pièces détachées et plans 15 1 Liste de pièces détachées ATTENTION La liste ci dessous contient des pièces qui ne sont pas présentes dans tous les types de pompes Pour commander des pièces veuillez toujours indiquer Type de pompe Année de cons...

Страница 37: ...37 15 2 Ersatzteilzeichnung Spare part drawings Onderdeeltekening Plans des pièces détchées TP 50 M TP 53 M TP 50 M Ex TP 53 M Ex TP 50 V TP 53 V TP 50 V Ex TP 53 V Ex ...

Страница 38: ...38 TP 70 M TP 70 M Ex TP 70 V TP 70 V Ex ...

Страница 39: ...xisch nein ja welche Stoffe _____________________ ätzend nein ja welche Stoffe _____________________ mikrobiologisch nein ja welche Stoffe _____________________ explosiv nein ja welche Stoffe _____________________ radioaktiv nein ja welche Stoffe _____________________ sonstige Schadstoffen nein ja welche Stoffe _____________________ Rechtsverbindliche Erklärung Hiermit versichern wir dass die Anga...

Страница 40: ..._______________ corrosive no yes which substance __________________ microbiological no yes which substance __________________ explosive no yes which substance __________________ radioactive no yes which substance __________________ other substances no yes which substance __________________ Legally binding declaration We hereby certify that the returned parts have been cleaned carefully To the best...

Отзывы: