36 | EngliSH

checked regularly. In normal operation mode this remains 
constant. Slight fluctuations depend on the properties of 
the pumped medium. Based on the power input damages 
and/or malfunctions of the impeller/propeller, bearing and/
or motor can be detected and repaired early. Major sec-
ondary damages can be prevented with this and the risk 
of a total failure can be reduced.

Check of the used switchgears for resistance, sealed 
space control etc.

Check the used switchgears for correct function. 

 

Defective devices must be replaced immediately, 
since the do not ensure protection of the machinery.  
Instructions for the test procedure must be followed  
(operating instructions for the respective switchgears).

Testing of insulation resistance

To check the insulation resistance, the power supply cable 
must be disconnected. Then, the resistance can be mea-
sured using an insulation tester (measuring DC voltage is 
1000 volts). 

The following values must be met:
During commissioning, the insulation resistance of 20 M

Ω

 

must be met or exceeded. For additional measurements, 
the value must be larger than 2 M

Ω

. Insulation resistance 

is too low: Moisture may have penetrated into the cable 
and/or the motor.

Do not connect machine; consult the manufacturer!

Visual inspection of the power supply leads

The power inlet leads must be inspected for bubbles, 
cracks, scratches, scour marks and/or crushing zones. 
If damages are detected, the damaged power inlet lead 
must be replaced immediately.

The leads may only be replaced by the manufacturer 
or an authorised/certified service workshop. The ma-
chinery must only be started after appropriate repair 
of the damage!

Visual inspection of the cable holders (biners) and the 
wiring (traction cable)

If the machine is used in basins/shafts the hoisting wires/
cable holders (biners) and the wiring are subject to con-
stant wear and tear. Regular inspections are required to 
prevent a complete wear and tear of the hoisting wires/
cable holders (biners) and/or wiring and a complete dam-
age to the power cable.

The hoisting wires/cable holders (biners) and the wir-
ing must be replaced immediately if there are slight 
signs of tear and wear!

Visual inspection of accessories

The accessories, such as for example suspension devic-
es, lifting devices, etc. must be checked for correct fitting. 
Loose or defective accessories must be repaired/replaced 
immediately.

Visual check for pumps with an oil barrier chamber 

Oil Level

Please take the precise filling quantity from the spare 
parts list or make a request to the manufacturer.

Oil Condition

The condition of the axial face seals can be checked by 
visually inspecting the oil. Place the pump horizontally so 
that the oil chamber check screw located on the side of 
the motor housing is facing up (for larger pumps; one of 
the two oil chamber control screws) Remove the screw 
and withdraw a small quantity of oil. If the oil is milky or 
cloudy, this indicates a defective shaft seal. 
In this case, have the condition of the shaft seals checked 
by a HOMA specialist workshop or the factory Cus-
tomer Service department. Oil type: biodegradable HO-
MA-ATOX. Used oil must be disposed of in accordance 
with the valid environmental regulations.

Functional test of safety and monitoring systems.

Monitoring devices, for example, are temperature sensors 
in the motor, sealing chamber control, motor protection 
relays, monitoring relays, etc. Motor protection relays and 
monitoring relays can generally be triggered manually for 
testing purposes. To check the sealing chamber control or 
the temperature sensor, the machine must be cooled to 
ambient temperature and the monitoring device‘s power 
cable in the switch cabinet must be disconnected. The 
monitoring device is then checked using an ohmmeter. 
The following values should be measured:

Bi-metal sensor:

 Value is equal to „0“ - throughput

Thermistor:

 A thermistor has a cooling resistance be-

tween 20 and 100 

Ω

. For 3 sensors in a series, this would 

equal a value of  60 - 300

Ω

.

PT100 sensor:

 PT100 sensors have a value of 100 

Ω

 at 

0°C. This value increases by 0.385 

Ω

 per 1°C between 

0°C and 100°C. An ambient temperature of 20°C there-
fore has a value of 107.7 

Ω

.

Sealing chamber control:

 The value must increase „in-

finitely“. Water may be present in the oil for lower values. 
Please refer to the instructions in the optionally available 
evaluation relay.

Please contact the manufacturer in the event of larger 
deviations!

The procedure for checking the safety and monitoring 
equipment for the auxiliary hoisting gear can be found in 
the respective operating manual..

General overhaul

During an overhaul, in addition to normal maintenance 
work, the motor bearings, shaft seals, O-rings and the 
power supply lines are also checked and replaced if nec-
essary. This work may only be performed by the manufac-
turer or an authorised/certified service workshop.

Changing operating fluid

The drained operating fluid must be checked for con-
tamination and water additions. If the operating fluid is 
seriously contaminated and more than 1/3 of the fluid is 
water, the fluid exchange must be repeated again after 

4 weeks

. If water is still present in the operating fluid, a 

seal may be defective. Please consult your manufacturer. 
When using sealing chamber or leakage monitoring, in the 
event of a defective seal, the display will light up again 
within the next 4 weeks after the exchange.

Содержание CH 413 Series

Страница 1: ...Original Betriebsanleitung EN Original Instruction Manual NL Originele handleiding CH413 CH432 CH436...

Страница 2: ...ten 08 3 3 Aufbau 08 4 Verpackung Transport und Lagerung 10 4 1 Anlieferung 10 4 2 Transport 10 4 3 Lagerung 10 4 4 R cklieferung 11 5 Aufstellung und Inbetriebnahme 11 5 1 Allgemein 11 5 2 Einbau 11...

Страница 3: ...zum Unfallschutz und zur Unfallverh tung Diese Betriebsanleitung muss dem Bedienpersonal jederzeit am Einsatzort des Produk tes verf gbar sein 1 3 Bestimmungsgem e Verwendung Die HOMA Produkte entspre...

Страница 4: ...ese Vereinbarungen laufen mindes tens bis zum vereinbarten Ende der Gew hrleistungszeit des Produktes 1 5 2 Ersatzteile An und Umbauten Es d rfen nur Originalersatzteile des Herstellers f r Reparatur...

Страница 5: ...ltdauer und die Spieldauer falls sie von 10 min abweicht Beispiel S3 30 bedeutet dass die Maschine 3 Minuten betrieben werden kann und anschlie end 7 Minuten abk hlen muss Schl rfbetrieb Der Schl rfbe...

Страница 6: ...ch keine Personen unter h ngenden Lasten aufhalten k nnen Weiterhin ist es untersagt h ngende Lasten ber Arbeitspl tze zu bewegen an denen sich Personen aufhalten Beim Einsatz von mobilen Arbeitsmitte...

Страница 7: ...Einsatz m ssen die Pumpen bestimmte Richtlinien erf llen Ebenso m ssen bestimmte Verhaltensregeln und Richtli nien vom Betreiber eingehalten werden Pumpen welche f r den Einsatz in explosiven Atmosph...

Страница 8: ...n CH43 sind f r den Dauerbetrieb S1 mit 15 Schaltungen Stunde ausgelegt 3 3 Aufbau Das voll berflutbare Aggregat besteht aus dem Motor dem Pumpengeh use und dem passendem Laufrad Alle wichtigen Bautei...

Страница 9: ...Ausl setemperaturen der Temperatur berwachung Sensoren Pumpe Motor Wicklung Normal T1 T3 Regler Wicklung Ex T1 T2 Begrenzer CH432 AM122 2pol 140 C 140 C CH436 AM136 2pol 140 C 140 C Automatische Schwi...

Страница 10: ...eschichtungen angreifen k nnen Bei Produkten mit Saug und oder Druckanschluss sind diese fest zu verschlie en um Verunreinigungen zu verhindern Alle Stromzuf hrungsleitungen sind gegen Abkni cken Besc...

Страница 11: ...age Demontage gegeben sind Ein Trockenlauf ist strengstens untersagt Wir emp fehlen daf r eine Niveausteuerung Verwenden sie Prallbleche f r den Zulauf So unter binden Sie einen Lufteintrag in das F r...

Страница 12: ...umpe ausgeschlossen ist Kette am Pumpen Traggriff bzw Trag sen befes tigen Pumpe mit den F hrungsklauen des Kupp lungsgegenflansches zwischen die F hrungsrohre im Schacht f hren Pumpe in den Schacht h...

Страница 13: ...d rfen nur von Fachkr ften ausgef hrt werden Diese Maschine ist nur f r den Einsatz bei den ange gebenen Betriebsbedingungen geeignet 5 5 Vorbereitende Arbeiten Die Maschine wurde nach dem neuesten St...

Страница 14: ...230 V 1Ph Motoren sind bei Auslieferung mit einem Schaltger t mit Motorschutzschalter Anlaufkon densator und Betriebskondensator ausgestattet Diese HOMA Schaltger te sind auch als Zubeh r lieferbar B...

Страница 15: ...d der Anlage m ssen vom Fachmann durchgef hrt werden Bei Ex zugelassenen Maschinen m ssen Sie auch das Kapitel Ex Schutz im Anhang beachten Bei Einsatz von leicht entz ndbaren L sungs und Reinigungsmi...

Страница 16: ...annung ist 1000Volt der Widerstand gemessen werden Folgende Werte d rfen nicht unterschritten werden Bei Erstinbetriebnahme darf der Isolationswiderstand 20 M nicht unterschreiten Bei weiteren Messung...

Страница 17: ...vicewerkstatt durchgef hrt werden Betriebsmittelwechsel Das abgelassene Betriebsmittel muss auf Verschmut zungen und Wasserbeimengungen kontrolliert werden Ist das Betriebsmittel stark verschmutzt und...

Страница 18: ...befestigung Zylinderschraube mit Innensechskant l sen und herausdrehen Achten Sie auf die Schraubensicherung Das Laufrad mit einem geeigneten Abzieher von der Welle abziehen Welle reinigen Neues Laufr...

Страница 19: ...tomerteilen und der Geh usebeschichtung vorzubeugen Bei Einlagerung in Werkst tten beachten Die Strah lung und die Gase die beim Elektroschwei en ent stehen zerst ren die Elastomere der Dichtungen Bei...

Страница 20: ...n Schieber in der Druckleitung geschlossen Schieber ganz ffnen Laufrad Propeller blockiert bzw abgebremst Maschine abschalten gegen Wiedereinschalten sichern Laufrad Pro peller gangbar machen Luft in...

Страница 21: ...ngseinrichtungen sind dann mit dem Lastkabel ausgef hrt Aderbezeichnung Motor berwachungseinrichtung berwachungen in der Wicklung T1 T2 Temperaturbegrenzer 2 Schalter in Reihe T1 T3 Temperaturregler 2...

Страница 22: ...Construction 28 4 Package Transport Storage 30 4 1 Delivery 30 4 2 Transport 30 4 3 Storage 30 4 4 Returning to the supplier 30 5 Installation and Commissioning 31 5 1 General 31 5 2 Fitting 31 5 3 Us...

Страница 23: ...rsonnel at all times and also be made available where the product is used 1 3 Proper use The HOMA products comply with the valid safety regu lations and meet the demands of state of the art tech nolog...

Страница 24: ...nufactur er may be used for repairs replacements add ons and conversions Only these parts guarantee a long working life and the highest level of safety These parts have been specially designed for our...

Страница 25: ...uct on or off depending on the filling level This is made possible by installing a float switch 2 Safety This chapter lists all the generally applicable safety instruc tions and technical information...

Страница 26: ...connec tion data sheet must be observed when connecting the product The technical specifications must be strictly adhered to If the machine has been switched off by a protective device it must not be...

Страница 27: ...s e g suspension unit and pipeline operating site immersion depth etc Once the product has been in stalled we recommend that the operator make additional measurements under all operating conditions Ca...

Страница 28: ...cy of 15 cir cuits hour 3 3 Construction The submersible aggregate consists of the motor the pump casing and the suitable impeller All important parts are of generous dimension No Description 1 Cable...

Страница 29: ...ed in the switchgear so that it switches off in the event of over heating Triggering temperature of the temperature monitor ing sensors Pump motor Standard winding T1 T3 Regulator Ex winding T1 T2 Lim...

Страница 30: ...re storage to prevent impurities The power supply cables should be protected against kinking damage and moisture Beware of electrical current Damaged power supply cables can cause fatal inju ry Defect...

Страница 31: ...unfavorable operating conditions and increased wear and tear No Description 1 Pipe 2 Coupling system 3 Service room 4 Inlet 5 Baffle plate 6 min liquid level 7 Pump 5 2 Fitting Danger of falls When mo...

Страница 32: ...o the shaft When the pump is sitting on the coupling foot it automatically seals itself from the discharge line and is ready for operation Hang the lowering chain on a hook at the shaft open ing Hang...

Страница 33: ...ints Cable run no loops slightly tightened Check temperature of the medium and submersion depth see machinery data sheet If a tube is used for pressure this must be rinsed with clear water prior to us...

Страница 34: ...tors are not equipped with switchgear with a circuit breaker These matching HOMA switchgears are available as accessories 5 9 Switch On Types Switch on types with plug switchgears Insert the plug into...

Страница 35: ...oils lubricants etc must be captured in a suitable container and must be disposed of according to the regulation 75 439 EEC and writ 5a 5b AbfG Waste Avoid ance and Management Act Respective protecti...

Страница 36: ...e axial face seals can be checked by visually inspecting the oil Place the pump horizontally so that the oil chamber check screw located on the side of the motor housing is facing up for larger pumps...

Страница 37: ...Fixing torque Nm for screws A2 A4 Coefficient of friction 0 2 A2 A4 Hardeness class 70 A2 A4 Hardeness class 80 DIN912 DIN933 DIN912 DIN933 M6 7 Nm 11 8 Nm M8 17 Nm 28 7 Nm M10 33 Nm 58 Nm M12 57 Nm 1...

Страница 38: ...sunshine as a pre ventive measure against brittleness in elastomer parts and the propeller and casing coating When storing the machine in a garage please remem ber Radiation and gases which occur dur...

Страница 39: ...ause Remedy There is no pumped medium Open inlet for container gate valve Inlet obstructed Clean inlet gate valve suction piece suction branch suction filter Impeller propeller blocked slowed down Swi...

Страница 40: ...operation Specialist to check connection and to correct if appropriate Wear and tear Replace worn parts Engine mount defective Contact the manufacturer Machine mounted askew Check assembly and use rub...

Страница 41: ...ring devices are run from the power cable Cable identification Motor Monitoring system Monitoring in winding T1 T2 Temperature limiter 2 switches in series T1 T4 Temperature controller 2 switches in s...

Страница 42: ...lag 50 4 1 Aanlevering 50 4 2 Transport 50 4 3 Opslag 50 4 4 Retourneren 51 5 Opstelling en inbedrijfstelling 51 5 1 Algemeen 51 5 2 Installatie 52 5 3 Toepassing van kettingen 53 5 4 Inbedrijfstellin...

Страница 43: ...ngevallenpreventie en of breidt deze uit Deze handleiding moet altijd beschikbaar zijn voor het bedie ningspersoneel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de...

Страница 44: ...afspraken lopen ten minste tot aan het overeengekomen einde van de wettelijke garan tietermijn van het product 1 5 2 Onderdelen aan en ombouwwerkzaamheden Er mogen uitsluitend originele onderdelen van...

Страница 45: ...wordt een gelijkblijvende tem peratuur bereikt die ook bij langer bedrijf niet meer stijgt Het materieel kan ononderbroken onder nominale belas ting werken zonder dat de toegestane temperatuur wordt...

Страница 46: ...onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder vallen Falen van de veiligheids en of bewakingscontro l...

Страница 47: ...el is verantwoordelijk voor de nale ving van de voorschriften Tijdens het bedrijf draaien bepaalde onderdelen waaier propeller om de vloeistof te verpompen Door bepaalde bestanddelen kunnen er aan dez...

Страница 48: ...xplosieve vloeistoffen bijv benzine kerosine etc is ten strengste verboden De producten zijn niet ontworpen voor deze vloeistoffen 3 3 Opbouw Het volledig overstroombare aggregaat bestaat uit de mo to...

Страница 49: ...e motor CH413 S3 40 Bedrijfswijze bij ondergedompelde motor CH43 S1 Toegestane mediumtemperatuur 40 C kortstondig 60 C Isolatieklasse H Beschermingsklasse IP68 Kabellengte 10 m Beschermslang CH43 poly...

Страница 50: ...gen worden gebruikt Deze moeten be schikken over voldoende draagvermogen en draagkracht zodat het product zonder risico s kan worden getranspor teerd Bij toepassing van kettingen moeten deze worden be...

Страница 51: ...leen een intacte coating beantwoordt aan het beoogde doel Wanneer u zich aan deze regels houdt kan uw product ge durende een langere periode worden opgeslagen Houd er echter rekening mee dat de elasto...

Страница 52: ...opstelling met automatisch koppelingssysteem De volgende instructie heeft betrekking op de montage van het originele HOMA koppelingssysteem Positie van koppelingsvoet en bovenste leidingcon sole voor...

Страница 53: ...akelpunt schakelen maar altijd onder de toevoer Belangrijk Na elke wijziging van de vlotterbevesti ging is het absoluut van belang dat met een testloop wordt gecontroleerd of de vlotterschakeling naar...

Страница 54: ...ermogen en kan er onder ongunstige omstandigheden schade ontstaan Gevaar door elektrische stroom Door ondeskundige omgang met stroom bestaat le vensgevaar Alle pompen met vrije kabeluiteinden moeten d...

Страница 55: ...op de nominale stroom Bij deellastbedrijf wordt aanbevolen de motorbeveiliging 5 boven de gemeten stroom op het werkpunt in te stellen De aanlooptijd bij verminderde spanning ca 70 mag max 3 s bedrage...

Страница 56: ...al en gereedschap van de machine Bewaar alle materialen en gereedschappen op de daarvoor bestemde plaats Vloeistoffen voor het bedrijf bijv olie smeermid delen etc moeten in geschikte reservoirs worde...

Страница 57: ...beschadigd raakt zijn regelmatige controles noodzakelijk De hijskabels kabelhouders karabijnhaken en de ka belspanning moeten bij geringe slijtage onmiddellijk worden vervangen Visuele controle van to...

Страница 58: ...nodig vervangen Deze werkzaamheden mogen uitsluitend door de fabrikant of een geautoriseerde ser vicewerkplaats worden uitgevoerd Vervangen van bedrijfsvloeistof De afgetapte bedrijfsvloeistof moet wo...

Страница 59: ...alleen onder de geldende be drijfs en gebruiksvoorwaarden plaatsvinden Droog lopen is niet toegestaan Negeren van deze aanwij zing kan leiden tot een total loss 8 2 Definitieve buitenbedrijfstelling o...

Страница 60: ...hanisme door vakman met de techn gege vens laten vergelijken en indien nodig corrigeren Waaier propeller door verklevingen verstoppingen en of vaste de len afgeremd verhoogd stroomverbruik Machine uit...

Страница 61: ...hijnselen Versleten onderdelen vervangen Motorlager defect Overleg met de fabriek Machine gespannen ingebouwd Montage controleren en indien nodig rubbercompensatoren gebruiken Verdere stappen voor de...

Страница 62: ...n met de hijskabel uitgevoerd Aderaanduiding motor Bewakingscontrole Bewakingen in de wikkeling T1 T2 Temperatuurbegrenzer 2 schakelaars in serie T1 T4 Temperatuurregelaar 2 schakelaars in serie T1 T2...

Страница 63: ...bedingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sons...

Страница 64: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bin...

Страница 65: ...ourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioac...

Страница 66: ...66...

Страница 67: ...our other household waste You are liable to dispose of all your electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous waste Isol...

Страница 68: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Отзывы: