ASSEMBLY
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
Seite 32
Zimmerer Tischkreissäge und Rollbahn / carpenter table saw and roller stand TS 400Z TS 400ZAL
13.3
Electrical connection
Check with a qualified electrician or service technician that the grounding instructions have
been understood and the machine is grounded!
A damaged cable must be replaced immediately!
Check whether the supply voltage and the current frequency as marked on the rating plate.
It is a deviation from the value of the supply voltage of ± 5% are permissible (eg: a machine
with a working voltage of 380V can work in the voltage range of 370 to 400V).
To determine the required cross section of the supply cable, use the data from the rating pla-
te and in the following table.
Energy consumption(А)
Cross-section of the conduit
fuse
bis 10
2.5 mm
2
12А АМ
von 10 bis 14
4.0 mm
2
16А АМ
von 14 bis 18
6.0 mm
2
20А АМ
von 18 bis 22
6.0 mm
2
25А АМ
von 22 bis 28
10.0 mm
2
32А АМ
von 28 bis 36
10.0 mm
2
40А АМ
von 36 bis 46
16.0 mm
2
50А АМ
ATTENTION
When working on an ungrounded machine:
Serious injury due to electric shock in the event of a malfunction possible!
Therefore:
Machine must be connected to a grounded outlet.