TROUBLE SHOOTING
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
42
TK 305
19
TROUBLE SHOOTING
W A R N I N G
Danger due to electrical voltage! Manipulating the machine with the power supply
up can lead to serious injuries or death. Always disconnect the machine from the
power supply before carrying out any troubleshooting work!
Many possible sources of error can be excluded in advance if the machine is properly connected
to the mains.
If you are unable to carry out necessary repairs properly and/or do not have the required
training, always consult a specialist to correct/solve the problem!
Trouble
Possible cause
Solution
Motor does not run
ON-OFF-switch defect
Repair switch
Motor defect
Exchange motor
No power supply
Connect to mains
Fuse or protection defect
Change fuse
Activate protection
Extention cord damaged
Change
Workpiece kick-back
Dull saw blade
Replace saw blade
Wrong assembled saw blade
Check direction / assemble
Blade does not reach the
necessary speed
Extention cord to long
Change
Weak power grid
Contact power suppliers
Machine vibrates heavily
Uneven surface
Reconstitute
Motor mount loose
Fix motor mount