TROUBLESHOOTING
HOLZMANN Maschinen Austria www.holzmann-maschinen.at
Seite 33
Schweißgerät/ welding machine MSA250
15
TROUBLESHOOTING
Troubles
Cause
Remedy
1.Fan not works
properly
1.the fan line lose
2.Fan breakage
1.Connect the line
2.Change the fan
2.No indicating on
the front panel
1.phase absent of the power
2.the fuse broken
3.Indicating light broken
1.Check the power
2.Change the fuse 15A/250V(back
panel)
3.Change it(φ8)
3.Over heating light on
1.aeration is not good
2.The temperature is too high
3.over-load use
4.Thermostat broken
5.Control plate broken
1.get rid of the bar 0.5m around
2.Reduce the temperature
3.Reduce the use loading
4.Change the thermostat(JUC-OF)
5.Check and change the control
plate
4.Wire feeder not work
1.the fuse broken
2.the cables are not connected
properly
3.the wire blocked
4.the drive circuit broken
5.other reasons
1.Change the fuse 15A/250V
(on back panel)
2.check the cables
3.Check the gun
4.Change the control panel
5.Contact with the namufacturer
6.Welding Voltage
and welding current not adjustable
1.Voltage switch line fall down
2. Voltage switch broken
3.fuse broken
4.the cables not connectecl
properly
1.Connect the lines
2.Change it
3.Change the fuse15A/250V(on
back panel)
4.Check it
Содержание MSA 250
Страница 39: ......