HOLYKELL HLU-SF Скачать руководство пользователя страница 8

MANUAL 

                                     

  HOLYKELL TECHNOLOGY COMPANY LIMITED

 

Tel: +86-731-89873265 Fax: +86-731-89873646 Mail: [email protected] Website: Http://www.holykell.com 

Address: Building No.5, No.8 Lu Tian road, Lugu High-Tech Development Zone, Changsha, Hunan of China 

sound... 

  gauge or power driver has been   

damaged.   

 

 

Has  display  and  sound, 

but the measuring   

numerical value   

disorderly jump, or 

numerical value is not 

change  according  to  the 

distance change... 

1. The depth of water meter installed too 

inclined, reflection is not good;   

2. The power setting too big, and then 

caused remaining vibration or diffraction 

is big; 

3. Don't properly used in air 

environment;   

4. There are two or more than two sets 

of water depth meter are working in 

close, causing echo interference;   

5. The water has too big electromagnetic 

interference; 6. Gain parameters has 

been modified artificially. 

1. Adjust the sensor’s axis and make 

it  perpendicular  to  the  water surface 

2.Generally, under 20 m range,   

power P is about 10, above 30 m   

range, power P is about 10 ~ 15 

  (also have special); 

3.Put the sensor into water to 

  measure;   

4.  Move  another  instrument    to  the 

distant measurement area;   

5.Shielding  interference;  6.Contact 

the  manufacturer  of  ultrasonic  water 

depth meter 

 

 

 

Sensor has sound and 

display horizontal line 

  "----" 

1.

Depth of water meter’s range is small, 

but the working range is too big;   

2.The application range is not wrong, the 

application  of  the  water  environment 

turbidity is too large or bed no reflection 

conditions, and can't get the echo; 

3. Setting of Power P is too small or too 

large. 

1. Adjust the working range of water 

depth meter to actual range; 

2. Adjust application environment to 

  appropriate  water  with  reflection 

plane;   

3.Access to user menu    the depth of 

water  meter  user  menu  and  change 

transmitted power, increase or   

decrease P until display is   

stable. 

 

 

 

 

The sensor has sound   

and the error of water   

depth value error is more   

than ten centimeters... 

1.There is a large obstacles in water   

under sensor, which cause reflection   

wave;   

2.The installation is too nearby the 

  shore side, wave distinguishes is reflex 

midway;   

3.Check whether it is correct of "N   

value" setting;   

4.Check whether it is normal of 

  temperature "C" value. 

1.2. Change installation places.     

3.Setting  correct  N  value  (please 

refer to the instruction);   

4.  If  the  temperature  difference  is 

more than ten degrees, it means the 

sensor  is  damaged,  please  contact 

supplier timely. 

 

1.The  range  migration  parameters  FX  1.Contact supplier;   

Содержание HLU-SF

Страница 1: ...abilities This instrument is a water depth measurement instrument of ultrasonic receive and dispatch sensor servo circuit temperature compensation salinity compensation and compensation circuit unit m...

Страница 2: ...8 Lu Tian road Lugu High Tech Development Zone Changsha Hunan of China 2 Instrument composition and port definition Charge Port Signal Output and wiring Display Keyboard Front Wall hung Charge Port Na...

Страница 3: ...g instrument Dimensions 235 115 70mm Operating voltage built in rechargeable lithium battery standby time of approximately 6 hours intermittent Sensor operating parameters Application medium fresh wat...

Страница 4: ...his key in working status will display P1 then press shift key to enter P1 menu to set or read parameters each time you press the page key will display the next menu total item is eleven Shift key pre...

Страница 5: ...N Salinity value Settings when salinity value is 0 for fresh water depth While used in sea water output corresponding value according to the current salinity of water Such as when salinity is 3 6 N s...

Страница 6: ...only work in the water It can t work in the air 3 It needs input N value salinity value in the P1 menu when it works in the sea water 4 Ultrasonic water depth sensor has been matched with instrument...

Страница 7: ...E6 is accumulating sum To enable users to enjoy better quality and frontier science technology achievement HLU SF products will continue to upgrade if there is a technical subject to change without p...

Страница 8: ...ea 5 Shielding interference 6 Contact the manufacturer of ultrasonic water depth meter Sensor has sound and display horizontal line 1 Depth of water meter s range is small but the working range is too...

Страница 9: ...tor or the manufacturer to set correct parameter 3 Charging in time The water depth meter of serial output and the upper host or PC cannot be online 1 The setting of extension baud rate is not consist...

Отзывы: