Rev. 1.40
16
March 29, 2019
Rev. 1.40
17
March 29, 2019
HT45F23A/HT45F24A
TinyPower
TM
Flash MCU with OPA & Comparators
HT45F23A/HT45F24A
TinyPower
TM
Flash MCU with OPA & Comparators
A.C. Characteristics
Ta=25
˚
C
Symbol
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
DD
Conditions
f
SYS1
System Clock
(HXT, ERC, HIRC)
—
2.2V~5.5V
400
—
4000
kHz
3.3V~5.5V
400
—
8000
kHz
f
SYS2
8MHz HIRC
3.3V
Ta=25˚C
-2%
8
+2%
MHz
3.3V
Ta=-40~85˚C
-5%
8
+5%
MHz
2.7V~5.5V
Ta=-40~85˚C
-10%
8
+10%
MHz
f
SYS3
4MHz HIRC
3.3V
Ta=25˚C
-2%
4
+2%
MHz
3.3V
Ta=-40~85˚C
-5%
4
+5%
MHz
2.7V~5.5V
Ta=-40~85˚C
-10%
4
+10%
MHz
f
SYS4
2MHz HIRC
3.3V
Ta=25˚C
-2%
2
+2%
MHz
3.3V
Ta=-40~85˚C
-5%
2
+5%
MHz
2.7V~5.5V
Ta=-40~85˚C
-10%
2
+10%
MHz
f
SYS5
910kHz HIRC
3.3V
Ta=25˚C
-2%
0.91
+2%
MHz
3.3V
Ta=-40~85˚C
-5%
0.91
+5%
MHz
2.7V~5.5V
Ta=-40~85˚C
-10%
0.91 +10%
MHz
f
LXT
System Clock (LXT)
—
—
—
32.768
—
kHz
f
ERC
4MHz ERC (Note 3)
3.3V
R=150kΩ, Ta=25˚C
-2%
4
+2%
MHz
3.3V
R=150kΩ, Ta=-40~85˚C
-8%
4
+8%
MHz
2.7V~5.5V
R=150kΩ, Ta=-40~85˚C
-15%
4
+15%
MHz
t
LIRC
32kHz RC Period
3V
—
28.10 31.25 34.40
µs
t
RES
External Reset Low Pulse Width
—
—
1
—
—
µs
t
LVR
Low Voltage width to Reset
—
—
60
120
240
µs
t
LVD
Low Voltage width to Interrupt
—
—
60
120
240
µs
t
LVDS
LVDO Stable Time
5V
LVR disable, LVD enable,
V
BG
is ready
—
—
100
µs
t
RSTD
System Reset Delay Time
(Power-on Reset)
—
—
—
100
—
ms
t
SST1
System start-up timer period
(W/O fast start-up) of HXT/TBC
—
Power up or wake-up from
Sleep mode
—
1024
—
t
SYS
*
note 1
t
SST2
System start-up timer period of
ERC, HIRC, EC
—
Power up or wake-up from
HALT (Idle or Sleep mode)
—
1
2
t
SYS
t
SST3
System start-up timer period
(With fast start-up) of HXT/TBC
—
wake-up from Idle mode
(f
SL
=f
TBC)
—
1
2
t
TBC
note 2
t
SST4
System start-up timer period
(With fast start-up) of HXT/TBC
—
wake-up from Idle mode
(f
SL
=f
LIRC
)
—
1
2
t
LIRC
t
INT
Interrupt Pulse Width
—
—
1
—
—
µs
t
AD
A/D Clock Period
—
—
0.5
—
—
µs
t
ADC
A/D Conversion Time
Note 4
—
—
—
16
—
t
AD
t
ON2ST
A/D on to A/D Start
—
2.2V~5.5V
2
—
—
µs
Note: 1. t
SYS
=1/f
SYS
; t
SUB
=1/f
SUB
2. t
TBC
is period of LXT or LIRC and it will not stop at Idle mode.
3. For f
ERC
, as the resistor tolerance will influence the frequency a precision resistor is recommended.
4. ADC conversion time (t
AD
)=n (bits ADC) + 4 (sampling time). The conversion for each bit needs one
ADC clock (t
AD
).