3  IAR Setup and Use

▀  

If the e-Link32 Pro is connected, a connection device named “HID-compliant device” will ap-

pear on the “Device Manager” window, and the corresponding Virtual COM Port will also be 

found, 

confirming that 

the installation has been successful.

Figure 38.  

e-Link32 Pro Device Name

e-Link32/e-Link32 Pro with IAR EWARM Setup and Use

▀  

Open the IAR EWARM project, and then open “Options”.

Figure 39.  IAR Options

Содержание e-Link32

Страница 1: ...e Link32 e Link32 Pro User s Guide Revision V1 30 Date November 13 2020...

Страница 2: ...ly Switching Power Configuration 9 e Link32 e Link32 Pro Schematic Diagram 9 2 MDK_ARM KEIL Setup and Use 13 e Link32 e Link32 Pro for Keil Installation 13 e Link32 e Link32 Pro with Keil4 Setup and U...

Страница 3: ...n Connector Pins 7 Table 2 Power Configuration SWD RESET UART Interface Voltage determined by the Target Board Power Supply 8 Table 3 Power Configuration MCU with Independent IO Power Supply 8 Table 4...

Страница 4: ...pport Package Installation Path 18 Figure 17 Keil Installation Completion 19 Figure 18 e Link32 Device Name 19 Figure 19 e Link32 Pro Device Name 20 Figure 20 Keil4 Debugger Selection 20 Figure 21 Kei...

Страница 5: ...User s Guide List of Figures Figure 40 IAR Debugger Selection 31 Figure 41 IAR e Link32 Debugger Setup 32 Figure 42 IAR e Link32 Pro Debugger Setup 33 Figure 43 IAR e Link32 Debugger Function Table 3...

Страница 6: ...e Link32 e Link32 Pro connects the target board via Serial Wire to the PC s USB port Users can then program and debug their embedded programs on the target board The e Link32 e Link32 Pro provides the...

Страница 7: ...iguration As the MCU has a wide operating voltage range the SWD and other interface IO voltages of the MCU may be different from the e Link32 e Link32 Pro which both operate at 3 3V To accommodate thi...

Страница 8: ...r to the target board VDD voltage Table 2 Power Configuration SWD RESET UART Interface Voltage determined by the Target Board Power Supply Resistor State Description R19 Exist Factory default 10k resi...

Страница 9: ...power configurations Table 5 Power Supply Switch J4 J4 Description SWD RESET UART interface voltage determined by the target board power supply Target board power supply provided by the e Link32 e Lin...

Страница 10: ...U6 SN74AVC1T45 1 5 3 4 6 2 VCCA DIR A B VCCB GND R6 470R C1 4 7nF R24 100R C21 0 01uF b e c Q2 MMBT9012 MMBT8550 1 2 3 C19 10uF R20 100R Y1 12 000MHZ R7 470R D3 Green led R25 100R J2 1 2 3 4 5 6 7 8 9...

Страница 11: ...ootloader GND The Level Shift VCCB Default Use TargetBoard Power Don t configure PD1 PD2 as Output or Enable Internal Pull Resistor Blue D1 Busy Red D2 Err VDD_elink32 LED1 LED2 3 2 1 4 Vin Vout GND T...

Страница 12: ...NC 1 R11 0 DAP_TX DAP_RX GND GND VCCB VCCB VDD_elink32 VDD_elink32 VCCB GND 1 2 S1 RESET IAP DAP_TX DAP_RX SWO PA14 UR1_RX UR1_TX DIR3 DIR3 1 R19 10k VCCB LED Filter CAP Power ESD Protector VDD_elink...

Страница 13: ..._ARM KEIL Setup and Use e Link32 e Link32 Pro for Keil Installation The following steps show how to install the e Link32 e Link32 Pro for Keil Double click HT32_Setup_Keil_vxx exe to open the Keil Boo...

Страница 14: ...nstallation path of the Keil Boot program is C Program Files x86 HT32_Setup_ Keil Select the desired installation path and press the Next button to continue Figure 7 HT32_Setup_Keil_vxx exe Installati...

Страница 15: ...he Next button to install the Holtek e Link32 USB Driver Figure 9 Holtek e Link32 USB Driver Installation Introduction The default installation path of the Holtek e Link32 USB Driver is C Program File...

Страница 16: ...appear Press the Finish button to enter the next Keil Plugin installation process Figure 11 Holtek e Link32 USB Driver Installation Completion If the Holtek e Link32 Keil Plugin has already been inst...

Страница 17: ...lation window will appear Press the Next button to continue Figure 13 Holtek e Link32 Keil Plugin Installation Introduction The Keil Plugin installation path is subject according to that of Keil4 Keil...

Страница 18: ...installation process then press the Next button to continue Figure 15 Holtek HT32 Keil Support Package Installation Introduction The Keil Support Package installation path is subject to that of the K...

Страница 19: ...d be selected to restart the computer Figure 17 Keil Installation Completion Connect the e Link32 e Link32 Pro to the PC s USB port Open the PC s Device Manager to check the connection status of the e...

Страница 20: ...er window and the corresponding Virtual COM Port will also be found confirming that the installation was successful Figure 19 e Link32 Pro Device Name e Link32 e Link32 Pro with Keil4 Setup and Use Op...

Страница 21: ...tings button on the right side to open the corresponding setting window Confirm that the setting is successful when the device ID is read The e Link32 setting window is shown below Figure 21 Keil4 e L...

Страница 22: ...ogramming Algorithm if there is no content or the content is not correct then press the Add button Figure 23 Keil4 Flash Download Setup e Link32 Pro with Keil5 Setup and Use No Support e Link32 Open t...

Страница 23: ...ick the Settings button on the right side to select the SW options Confirm that the setting is successful when the device ID is read Figure 25 Keil5 Debugger Setup Click Flash Download to check Progra...

Страница 24: ...AR Setup and Use e Link32 e Link32 Pro for IAR Installation The following steps show how to install the e Link32 e Link32 Pro for IAR Double click HT32_Setup_IAR_vxx exe to open the IAR Boot program a...

Страница 25: ...llation path of the IAR Boot program is C Program Files x86 HT32_Setup_ IAR Select the desired installation path and press the Next button to continue Figure 28 HT32_Setup_IAR_vxx exe Installation Pat...

Страница 26: ...xt button to install the Holtek e Link32 USB Driver Figure 30 Holtek e Link32 USB Driver Installation Introduction The default installation path of the Holtek e Link32 USB Driver is C Program Files x8...

Страница 27: ...appear Press the Finish button to enter the next IAR Plugin installation process Figure 32 Holtek e Link32 USB Driver Installation Completion If the Holtek e Link32 IAR Plugin has already been install...

Страница 28: ...Plugin installation window will appear Press the Next button to continue Figure 34 Holtek e Link32 IAR Plugin Installation Introduction The default installation path of the IAR Plugin is C Program Fil...

Страница 29: ...ltek HT32 IAR Support Package Installation Introduction Once the installation has finished press the Finish button Connect the e Link32 e Link32 Pro to the PC s USB port Open the PC s Device Manager t...

Страница 30: ...ce named HID compliant device will ap pear on the Device Manager window and the corresponding Virtual COM Port will also be found confirming that the installation has been successful Figure 38 e Link3...

Страница 31: ...ev 1 30 31 of 34 November 13 2020 e Link32 e Link32 Pro User s Guide 3 IAR Setup and Use Click Debugger to select RDI for e Link32 or select CMSIS DAP for e Link32 Pro Figure 40 IAR Debugger Selection...

Страница 32: ...ber 13 2020 e Link32 e Link32 Pro User s Guide 3 IAR Setup and Use Setting the selected debugger Check wheather e Link32_rdi dll is selected in Manufacturer RDI driver for e Link32 RDI Figure 41 IAR e...

Страница 33: ...Interface option to SWD mode for e Link32 Pro CMSIS DAP Figure 42 IAR e Link32 Pro Debugger Setup Once the settings have finished the corresponding debugger options will appear on the function table F...

Страница 34: ...ed solely for the purpose of illustration and Holtek makes no warranty or representation that such applications will be suitable without further modification nor recommends the use of its products for...

Отзывы: