Specifications

Manual Type 6.2.0.10-RF

VIO Intercom with Essex 

“S-12 Stand - Alone” Keypad

For Models

400-S12-VIO2      410-S12-VIO2                  

Access Control

Essex “stand-alone” 12 button keypad
1 relay plus 2 grounding outputs 
(external relays required)
500 users
12 VDC power supply included

INSTALLATION

INSTRUCTIONS

501 E. Goetz Ave.

Santa Ana, Ca 92707

www.eholovision.com

Ph. 714-434-6904

Fax 800-362-0002

HOLOVISION

Not Used

12 VDC input (for keypad)

NO, COM, NC relay connections

Keypad case ground

Remote bypass terminals (activate relay)

Connect tamper switch to alarm (optional)

Not Used

Communication

Holovision VIO is a SIP enabled intercom module devel-
oped  specifically  with  the  custom  integrator  in  mind.  It
works  with  Crestron  RAVA/SIP  and  most  SIP  enabled
VoIP phone systems and servers.

Cut for NO Contact Closure

AC Loop for Strike

Содержание 400-S12-VIO2

Страница 1: ...z Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION Not Used 12 VDC input for keypad NO COM NC relay connections Keypad case ground Remote bypass terminals activat...

Страница 2: ...be created when power is removed from the strike Loop is required from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0 10 RF Remote B...

Страница 3: ...g Contact Closure for Gate Operation Page 3 Type 6 2 0 10 RF Gate Motor Link Status Power Reset Mic Mic Spk Spk Button Button Gnd NC NO COM 12 VDC from Relay OFF PoE On VIO2 Everyday VoIP from Holovis...

Страница 4: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Страница 5: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Страница 6: ...VIO sip QUICK START Page 6 Type 6 2 0 10 RF...

Страница 7: ...22 Page 7 Type 6 2 0 10 RF...

Страница 8: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION BE...

Страница 9: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Страница 10: ...te programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In th...

Страница 11: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay Op...

Страница 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: