background image

Cut for NO Contact Closure

AC Loop for Strike

12v -

12v +

CO line

12vDC

1.5 A

TO STANDARD

PHONES

Gate Strike

*

MOV is recommended

NOTE: MOV (metal oxide varistor) is the small red component which is included. Its purpose is to absorb “inductive kick

back” which can be created when power is removed from the strike.

Loop is required from 12v positive to contact common for DC power to strike.

Essex Keypad Wiring

DC Out for Gate Strike

Page 2                                                                                                                

Type 6.2.0.5-RF

NOTE

:

‘’Talk  Battery’’  switch

must be in “ON” position

when  the  C-1000B  is

used  w/o  a  CO  line

input.

VIKING 

Model C-1000B

1    2 3 4  5  6 7   8 9 10 11 12 13 14 15 16  17 18 19 

EA

RT

H G

ND

PH

ON

E L

INE

 IN

PU

T

LIN

E O

UT

 TO

 PH

ON

ES

KE

YL

ES

S C

ON

TA

CT

DO

OR

  B

OX

 1

DO

OR

 BO

X P

OW

ER

DO

OR

  B

OX

 2

DO

OR

 ST

RIK

E 1

DO

OR

 ST

RIK

E 2

1     2     3

1   2    3    4   5   6    7   8    9  10  11 12  13 14 15 16  17 18 19

OFF                ON

13.8 VAC

1.25A

Remote

Bypass

Button

Содержание 400-S12-VIK

Страница 1: ...trol Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays required 500 users 12 VDC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 ww...

Страница 2: ...ired from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0 5 RF NOTE Talk Battery switch must be in ON position when the C 1000B is us...

Страница 3: ...when the C 1000B is used w o a CO line input Gate Motor VIKING Model C 1000B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 EARTH GND PHONE LINE INPUT LINE OUT TO PHONES KEYLESS CONTACT DOOR BOX 1 DO...

Страница 4: ...ON 10 ON ON 30 C 1000B Door Controller Programming 1 Disconnect the PHONE LINE INPUT 2 Slide the TALK BATTERY switch to the ON position 3 Move DIP SWITCH 2 from OFF to ON 4 Connect a phone to termina...

Страница 5: ...ition 2 Move DIP SWITCH 2 from ON to OFF 3 Re connect the PHONE LINE INPUT and LINE OUT TO PHONES Return to normal use mode Step Action OPERATION OF C 1000B ANSWER A CALL FROM DOORBOX When the phones...

Страница 6: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION B...

Страница 7: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Страница 8: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Страница 9: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Страница 10: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: