1
The
“NO RING”
option is to be used if external door chimes are being used in the house, and the phones should not ring when the
door bell button is pushed. When the
“NO RING”
option is selected, the phones will not ring. When the homeowner hears the
external door chime (not supplied by Holovision), and then picks up any telephone, they will be automatically connected to the door
phone. No additional buttons need to be pushed. The door call will be available for 10 seconds after the button is pushed.
After 10 seconds, follow the instructions shown for
“Basic Operation of TES2”.
2
For
“NO RING”
option, install jumper pin (J6) on far right side of board. TES2 is shipped with this option disabled.
3
In order to connect door chimes and TES2,
a double pole button must be used
. The double pole button (Part number 9202) is
available from holovision.
Set “No Ring” Option
(TES2 is shipped with this option
DISABLED
)
Step
Action
1
For
“NO CO”
option is to be used if there is no CO (Central Office) line to the home. The No CO option would be used if the
homeowners used cell phone only (no house phone line). In this case, several phones would be required throughout the house. These
phones would be used only for answering door phone calls.
2
For
“NO CO”
option, install 2 jumper pins if (J3, J4) at th bottom of the board. TES2 is shipped with this option disabled.
Set “No CO Line” Option
(TES2 is shipped with this option
DISABLED
)
Step
Action
1
The relay board is equipped with screw terminals. This has connections for each relay in normally open
(“NO”)
and
normally closed
(“NC”)
options.
2
Attach to either NO or NC connectors. If a second gate is being used, also connect it to NO or NC connectors.
Connect Gate Strike Relay
Step
Action
TES2 Telephone Entry System
1
Mount the main board near the telephone distribution center of the house and attach the telephone line from the service provider to the
connection labeled “
LINE TO DEMARC
”.
2
Connect the house phone distribution system to the wire terminals labeled “
HOUSE PHONE
”.
3
Punch down
“ONE”
and
“TWO”
door stations. If only one door station is being used, it should be connected on the
“ONE”
punch down
location.
Note: The connection is polarity sensitive.
Step
Action
Basic Set-Up
Page 4
TYPE 6.5.0.7-RF