912-00167-001 REV.B
5. FAO Setting
Field Adjustable Output Module
The Field Adjustable Output (AO) module is an onboard
device that adjusts the light output and input wattage to
meet site specific requirements, allowing a single fixture
configuration to be flexibly applied in many different
applications. The default from the factory is set to 8. The
data is either the percentage of Lumens or Watts.
5.1. AO settings with 3LC, 4LC & 5LC Optics
P10 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
Not Available
7
94%
94%
6
83%
81%
5
71%
69%
4
59%
57%
3
48%
44%
2
36%
33%
1
24%
22%
P20 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
Not Available
7
94%
94%
6
83%
81%
5
71%
69%
4
59%
56%
3
47%
44%
2
35%
32%
1
22%
22%
P30 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
100%
100%
7
94%
94%
94%
95%
6
83%
81%
83%
84%
5
71%
68%
71%
73%
4
59%
56%
59%
62%
3
47%
43%
47%
51%
2
34%
31%
34%
41%
1
22%
22%
22%
29%
P40 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
100%
100%
7
94%
94%
94%
94%
6
83%
82%
83%
83%
5
71%
70%
71%
71%
4
59%
58%
59%
60%
3
46%
47%
46%
49%
2
34%
35%
34%
38%
1
21%
24%
21%
27%
P50 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
100%
100%
7
94%
94%
94%
94%
6
83%
81%
83%
82%
5
71%
69%
71%
70%
4
59%
57%
59%
58%
3
46%
45%
46%
47%
2
34%
33%
34%
35%
1
21%
22%
21%
24%
P60 with Optics 3LC, 4LC or 5LC
Dial
Setting
MVOLT
HVOLT
Lumens Watts Lumens Watts
8
100%
100%
100%
100%
7
94%
94%
94%
94%
6
83%
81%
83%
81%
5
71%
69%
71%
69%
4
59%
56%
59%
57%
3
47%
44%
47%
46%
2
34%
32%
34%
34%
1
20%
21%
20%
22%