Holmes HM1865-U Скачать руководство пользователя страница 2

setting. Then adjust the set humidity by using the up and

down buttons.  Humidity will increase in increments of 5%.

When the humidity level is set, the display will return to show

the current room humidity. When the room humidity level

rises above the set humidity, the humidifier will stop.  When

the humidity level drops below the set humidity, the

humidifier will turn on automatically.

NOTE:

Allow up to 30 minutes for the filter to fully absorb

water and for the unit to produce moisture.

NOTE:

The AccuSet Plus

Humidifier has memory. This

means that when you turn the unit back on, it will be at the

last setting the humidifier was set at.
If you do not plan to use the humidifier for two or more days,

make sure any residual water is drained from the water tank,

base and wick filter to prevent algae or bacteria growth.

Extended Run Time Setting:

By setting your humidifier to a specific humidity level, you

are actually also extending the run time. Since the unit will

turn on and off to maintain the set humidity level, less water

will be used than on manual setting.

16 HOUR AUTO ON/OFF TIMER
INSTRUCTIONS

The Auto On/Off timer will allow the user two options, to

set a time to turn the unit off or to set a time to turn the

unit on. 

Auto Off Timer

While the unit is running, the off timer can be activated by

holding down the up and down buttons simultaneously for

2 seconds, the screen will flash 00 and the up and down

arrows can be pushed to adjust the timer up to 16 hours in

increments of one, once 16 hours is reached, the next push

of the timer button will cycle back to 00 hours. The Timer

Light (     ) will illuminate when the Timer is set. The unit

will then shut off after the timer expires (in its current

setting). While the unit is running, the timer should stay on

even if other modes are being changed. The timer should

only be deactivated if the unit is turned off.

Auto On Timer

While the unit is off, the up and down buttons are pressed

simultaneously for 2 seconds and the display will flash 00

the up button may then be pushed again to increase the

hours to turn on (in its last setting) from 1-16 in

increments of 1 hour. The unit will then come on after the

timer expires, if the unit is then turned on, the timer will

be deactivated. The Timer Light (     ) will illuminate when

the Timer is set. Once 16 hours is reached, the next push

of the timer button will cycle back to 00 hours .

REPLACING THE FILTERS

Through normal use, waterborne minerals and sediment

become trapped in the wick filter. The harder your water, the

greater the amount of minerals in the water, and the more

often you will need to change your filter.
You will be able to monitor the life of the filter in your

humidifier by checking the FilterCheck

®

Indicator. When the

unit is off, the FilterCheck

®

Indicator will read in the OFF

position. 

NOTE:

After 60 minutes of use, FilterCheck

®

Indicator will

move from the OFF position and

indicate your filter condition. A

brand new filter will register in the

section reading GOOD filter. After

frequent use of your humidifier,

the FilterCheck

®

Indicator will let

you know when the filters need to

be changed, see Figure 2.

When the needle is in the

CHANGE section, this means the

proper amount of moisture is not getting into your air

due to the excessive minerals and sediment that have

become trapped on your filters. At this point, you should

replace your filter. It is important to change your filter as

indicated to obtain stated performance level.

To replace the filter, follow the steps below:

1. Turn the unit off and disconnect from the electrical outlet.

2. Remove the tank and main housing to access the base tray.

3. Remove wick and discard. 

4. Follow the weekly cleaning instructions.

5. Insert new filter.

6. Repeat Operating Instructions steps.

It will take about 30 minutes for the humidifier to reach

maximum output.
You can purchase replacement filters (model HWF65) at a

local retailer, by calling 1-800-546-5637, or by visiting

www.holmesproducts.com. It is recommended that a

replacement filter is purchased for uninterrupted use.

CLEANING AND MAINTENANCE
INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry,

heated indoor air. To benefit most from the humidifier and

avoid product misuse, follow all instructions carefully.  Please

note that this is an electrical appliance and requires attention

when in use.
In addition, if you do not follow the recommended care and

maintenance guidelines, micro-organisms may be able to

grow in the water within the water tank.  You must routinely

follow the cleaning procedures that follow in order to ensure

proper, efficient operation of your humidifier.  Proper

maintenance and cleaning is essential to the continued

performance of your unit and the avoidance of algae or

bacteria build-up.

DAILY MAINTENANCE

1. Be sure the unit is OFF and is disconnected from the

electrical outlet.

2. Remove the housing and the tank from the humidifier

and place in sink or tub.

3. Carry the base of the unit to the sink, remove the wick,

place in sink, drain any remaining water and rinse

thoroughly to remove any sediment or dirt. Wipe clean,

and dry with a clean cloth or paper towel. 

4. Drain the water from the tank into the sink and rinse

tank thoroughly. Wipe clean, and dry with a clean cloth

or paper towel.

5. Put filter back in, replace the housing, then refill tank

with cool tap water as instructed earlier in the Filling

Instructions.  Do not overfill.

6. Follow Operating Instructions.

WEEKLY MAINTENANCE

To Remove Scale:

1. Repeat steps 1-4 above.

2. Clean the base by partially filling the base with one 8-oz

cups of undiluted white vinegar, or by using 

Cleanse Clean

®

solution (Model S1710) by the

manufacturer. Leave this solution in the base for 20

minutes, while cleaning the all interior surfaces with a

soft brush. Remove base scale by wiping the base with a

cloth dampened with undiluted white vinegar.

3. Rinse with clean warm water to remove the cleaning

solution before disinfecting the tank.

To Disinfect Humidifier Base and Tank:

1. Fill humidifier base with 1/4 gallon of water and 1/2

teaspoon of chlorine bleach.

2. Fill the tank 1/2 full with water and 1/2 teaspoon of

chlorine bleach.

3. Let the solution stand for 20 minutes, swishing every few

minutes. Wet all surfaces.

4. Carefully empty the base and tank after 20 minutes, and

rinse with water until you cannot detect any bleach

smell.  Dry with a clean cloth or paper towel.

5. Check the FilterCheck

®

Indicator to see if it is time to

replace the filter.  Depending on water hardness in your

area, it may be necessary to change the filter every 1-2

months.  Reinsert the wick filter into the base. 

6. Refill the water tank as directed with cool tap water,

replace the humidifier housing, and turn the unit on.

PLEASE READ AND SAVE

THESE IMPORTANT SAFETY

INSTRUCTIONS

Consumer Safety Information
NOTE:

This is an electrical appliance and requires attention

when in use.

NOTE:

If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has plenty of

humidity and additional moisture may cause damage.

NOTE:

DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to reduce

the hazards of becoming tangled in, or tripping over a longer

cord. If a longer cord is necessary an approved extension cord

may be used. The electrical rating of the extension cord must be

equal to or greater than the rating of the humidifier (refer to

the rating artwork placed on the humidifier). Care must be

taken to arrange the extension cord so that it will not drape

over the countertop or tabletop where it can be pulled on by

children or accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes

®

Cool Mist humidifier draws dry air through the

rear air intake grill area. This air is then passed through a

moisture–laden wick filter, which retains the minerals and

deposits in the water. The resulting moist air is directed back

into the room from the top air grill.

NOTE: 

This humidification system provides a cool, invisible

moisture output. It is normal not to see the mist.

NOTE:

A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched to OFF and the unit is

disconnected from the electrical outlet.

2. Select a location for your humidifier, on a flat surface,

about 4 inches (10 cm) away from the wall. DO NOT

place the humidifier on a finished floor or near

furniture, which can be damaged by moisture or water.

Place on a moisture-resistant surface.

FILLING THE WATER TANK

1. Remove the tank from the base of the humidifier and

bring to the faucet. Turn the tank upside down and twist

off the tank cap by turning counter clockwise. Fill tank

with cool, fresh tap water. DO NOT fill with warm water

as this may cause leaking. Replace the cap on tank

FIRMLY.

2. When full, carry tank to the humidifier and place onto

the base. The tank holds 2.25 gallons of water and the

base holds 1/4 gallons of water. The tank will

immediately begin to empty into base.

3. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

Your humidifier is equipped with a technologically advanced

AccuSet Plus

digital Humidistat. You can set the humidifier

to run continuously in manual mode or set the AccuSet Plus

digital Humidistat to your desired humidity setting. The

AccuSet Plus

digital Humidistat will automatically turn the

humidifier ON or OFF, depending on the preset comfort level.

The comfort level ranges between 35% and 65% relative

humidity.

Manual Mode Instructions:

1. Plug the humidifier into a 120V AC electrical outlet.

2. The display will show the current room humidity.

NOTE:

The display range is 21% - 90%. If your room

humidity level falls below 21%, the unit will display 21. If

your room humidity level rises above 90%, the unit will

display 90.

3. To start the unit, push the MODE (

) button twice

within 3 seconds for the HIGH (3) manual setting.

4. Press the (

) button again for the MEDIUM (2) manual

setting and again for LOW (1). After the selection is made,

the display will return to show the current room humidity.

5. To stop the unit, press and hold the (

) button for two

seconds, or keep pressing the button until the display

reads OFF (OF).

AccuSet Plus™ HUMIDISTAT INSTRUCTIONS

To take advantage of the AccuSet Plus

Digital Humidistat,

press the MODE (

) button until the speed is set in either

the auto HIGH (A3), auto MEDIUM (A2) or auto LOW (A1)

P L E A S E   R E A D   A N D   S AV E   T H E S E

I M P O R TA N T   S A F E T Y   I N S T R U C T I O N S

F E AT U R E S   -   O P E R AT I O N S

1. Read all instructions before using the appliance.

2. To avoid fire or shock hazard, plug the appliance directly

into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your humidifier

on an inside wall near an electrical outlet. The humidifier

should be at least 4 inches (10 cm) away from the wall

for best results.

5. NEVER place humidifier in an area where it is accessible to

children. NEVER use humidifier in a closed room, particularly

where a child may be sleeping, resting, or playing (a closed

room may result in excessive humidity).

6.

WARNING:

Do not attempt to refill humidifier without

first unplugging the unit from its electrical outlet. Failure to

heed this warning may cause personal injury. Be sure to

unplug the unit by pulling on the plug and not the cord.

7. Never place anything over moisture outlet when the unit

is running.

8. NEVER drop or insert any object into any openings.

9. DO NOT operate any appliance with a damaged cord or

plug, after the appliance malfunctions, or if it has been

dropped or damaged in any manner. Return appliance

to manufacturer for examination, electrical or

mechanical adjustment, or repair.

10. Use appliance only for intended household use as described

in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to

persons. The use of attachments not recommended or sold

by the manufacturer may cause hazards.

11. DO NOT use outdoors.

12. Always place humidifier on a firm, flat, level surface. A

waterproof mat or pad is recommended for use under the

humidifier. NEVER place it on a rug or carpet, or on a finished

floor that may be damaged by exposure to water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the wall.

Moisture could cause damage, particularly to wall paper.

14. Humidifier should be unplugged when not in use.

15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly maintenance

to operate appropriately. Refer to daily and weekly

cleaning procedures. Use only cleaners and additives

recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner, furniture

polish, paint thinner, or other household solvents to

clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

19. Do not use humidifier in an area where humidity level is

in excess of 50%. Use a hygrometer, available at your

local retailer or through the manufacturer, to measure

the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit.  Doing so will void

your warranty.  The inside of the unit contains no user

serviceable parts. All servicing should be performed by

qualified personnel only.

21. Never place housing under water flow or immerse in

liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the water

tank.

24. To prevent damage to surfaces, do not place humidifier

under overhanging surfaces.

25. NEVER operate unit without water in the tank.

26. Do not move unit after it has been used until unit cools

completely.

27. Use both hands when carrying full tank of water.

F E AT U R E S   -   O P E R AT I O N S

C L E A N I N G / M A I N T E N A N C E

I N S T R U C T I O N S

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in a

polarized outlet only one way. If the plug does not fit fully in the outlet,

reverse the plug. If it still does not fit, contact a qualified electrician to

install the proper outlet. 

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS 

SAFETY FEATURE IN ANY WAY.

Figure 1

A. Water Tank 
B. Carry Handle
C. FilterCheck

®

Indicator

D. Humidifier Housing
E. Control Panel
F. Humidifier Base

D

B

A

E

F

C

Figure 2

HM1865-U_08EM1.qxd:9100030005310  5/15/08  11:32 AM  Page 2