background image

                                                                                                                                                                                                 

HP FUEL PUMPS 

P/N 12-700 & 12-890 

Installation Instructions 199R10569

 

 

WARNING!   THESE INSTRUCTIONS MUST BE READ AND FULLY UNDERSTOOD BEFORE BEGINNING INSTALLATION.  FAILURE TO 

FOLLOW THESE INSTRUCTIONS MAY RESULT IN POOR PERFORMANCE, VEHICLE DAMAGE, PERSONAL INJURY, OR DEATH.  

IF THESE INSTRUCTIONS ARE NOT FULLY UNDERSTOOD, INSTALLATION SHOULD NOT BE ATTEMPTED.  PLEASE CONSULT 

HOLLEY TECH SERVICE OR A QUALIFIED MECHANIC. 

 

NOTE:

  NOT FOR USE WITH METHANOL!  Will work with E-85! 

 

 

APPLICATIONS: 

Naturally 

Aspirated

Forced 

Induction Inlet Outlet Inlet Outlet Return

Pre

Post

Pre

Post

Carb

EFI

12-700

75 @ 8PSI                            

57 @ 43PSI                              

47 @ 60 PSI

Street/Strip Gasoline / Diesel

Yes

900                         
700                                       
550

690                         
530                              
430

-8AN -8AN -6 AN -6AN

-6AN 162-564 162-555 162-564 162-554 12-845 12-846 13 Amps

12-890

96 @ 8PSI                          

76 @ 43PSI                                 

70 @ 60 PSI

Street/Race Gasoline / Diesel

Yes

1050                            

900                                            
800 

800                                 
700                                         
600 

-8AN -8AN -8AN -6AN

-6AN 162-564 162-555 162-564 162-554 12-845 12-846 18 Amps

The pumps below do not have an internal bypass. A bypass style regulator and return line are required. 

Max Amp 

Draw

Part 

Number

Holley Recommendations for Peak Performance

Pump Fitting 

Size

Recommended 

Regulator  

Fuel Filter  

(Carbureted)

Fuel Filter                       

(Fuel injected)

Max HP*

GPH Flow at Rated 

PSI and 13.5V

Application Fuel Compatibility

Minimum 

Recommended Line 

Compatible up 

to 18.5V

 

 

 

PARTS REQUIRED FOR INSTALLATION: 

 

 

Pre-Filter  

 

Post-Filter 

 

Relay Kit (30amp minimum) – Holley P/N 12-753 or equivalent 

 

Safety Shutoff Switch (Holley P/N 12-810 or equivalent) 

 

Fuel hose & fittings 

 

Wire & connectors 

 

Mounting hardware 

 

NOTE:

  These pumps are not serviceable in the field.  Contact Holley tech service for fuel pump service. 

 

 

INTRODUCTION:

 

 

Congratulations on your purchase of the

 Holley HP Fuel Pump.  

This instruction sheet contains all the information needed to install this fuel pump.  

Please read all the 

WARNINGS 

and 

NOTES

.  They contain valuable information that can save you time and money.  Holley Performance Products 

cannot and will not be responsible for any alleged or actual engine or other damage, or other conditions resulting from misapplication of the fuel pumps 

and fuel pressure regulators described herein.  However, it is our intent to provide the best possible products for our customer; products that perform 

properly and satisfy your expectations.  Should you need information or parts assistance, please contact Technical Service at 1-270-781-9741, M-F, 8 

a.m. to 6 p.m. & Sat. 9 a.m. to 3 p.m. CST.  Please have the P/N ready when calling. 

 

NOTE:

   A screen type pre-filter (100 micron), a top quality post fuel filter, fuel hose and clamps, 12 gauge wire, fuel fittings, assorted terminals, a relay 

kit (12-753), and an optional safety shut-off switch (12-810) is required to complete the installation of the Holley HP fuel pump.  These parts 

are not included with the fuel pump. 

 

NOTE:

   These Holley HP fuel pumps require the use of a bypass style fuel pressure regulator (Part number 12-845 for carbureted applications and 12-

846 for EFI applications).   

 

NOTE:   

The Holley HP fuel pump utilizes o-ring sealed inlet/outlet ports.  The ports utilize ¾-16 O-ring (-8AN) threads.  These ports are not pipe 

thread, therefore 

Do not use thread sealant.  

 

NOTE:   

Holley 

ALWAYS RECOMMENDS

 using our oil pressure safety shut-off switch, part number 12-810. 

 

 

PUMP MOUNTING AND INSTALLATION:

 

 

The best location for mounting any electric fuel pump is the rear of the vehicle, near the fuel tank and in a position even with or below the bottom of the 

tank, allowing the fuel to be gravity fed to the pump.  

The pump should be mounted on a solid member, such as the chassis, with the pump 

outlet pointing forward or upward.

  Avoid exposure of the pump and fuel lines to moving parts and to any hot areas, such as the exhaust manifold.  

The pump should not be mounted in an enclosed area, such as the vehicle’s trunk.  Follow the steps below for mounting the pump. 

 

Содержание 12-700

Страница 1: ...RNINGS and NOTES They contain valuable information that can save you time and money Holley Performance Products cannot and will not be responsible for any alleged or actual engine or other damage or other conditions resulting from misapplication of the fuel pumps and fuel pressure regulators described herein However it is our intent to provide the best possible products for our customer products t...

Страница 2: ... then to the post filter See Figures 1a and 1b NOTE Avoid unnecessary restrictions such as sharp bends and undersized fuel fittings and hoses Avoid routing fuel lines in areas that would cause chafing All fuel line connections must be leak proof WARNING IF SPLICING INTO EXISTING FUEL LINES USE EXTREME CARE TO AVOID CONTAMINATING THE LINE WITH RUBBER OR METAL SHAVINGS AS THIS WILL DAMAGE THE PUMP I...

Страница 3: ...fety switch and relay 1 WIRING THE FUEL PUMP WITH A RELAY NOTE You will need Holley Fuel pump relay kit P N 12 753 or equivalent 4 wire relay 1 Disconnect the cables from the battery 2 Mount relay on firewall of engine compartment or other suitable location using a sheet metal screw WARNING Before punching or drilling a hole in the firewall make sure you know what is on the other side to avoid pun...

Страница 4: ...ring circuit This will ensure that the pump will not continue to operate after the engine is shut off and or when the key is left in the ON position If the pressure switch is to be used follow the installation instructions as outlined below refer to Figure 3 Use 12 gauge wire for power BAT and ground wires 1 Disconnect the cables from the battery 2 Remove the original equipment oil pressure switch...

Страница 5: ...o the remaining red wire of the relay harness After attaching the fuse holder insert a 25A fuse and connect to the positive side of the battery using 12 gauge wire 13 Connect the terminal marked NO of the safety switch to a switched 12V source 14 Connect the terminal marked NC of the safety switch to the starter terminal that s hot 12V during cranking only 15 Reconnect the battery cables SERVICE P...

Страница 6: ...6 Holley Technical Support Phone 1 270 781 9741 Fax 1 270 781 9772 For online help please refer to the Tech Service section of our website www holley com 199R10569 Revision Date 6 12 12 ...

Отзывы: