VII.  Operating Instructions 

 

Preparation and Precautions Prior to Use 

 

a.  The instrument must be placed on a flat and level surface composed of non-combustible 

materials. 

b.  300mm (minimum) of clearance is required around the instrument to ensure the front 

and back ventilation grilles are well ventilated. 

c.  This instrument is equipped with a compressor. If the instrument is transported, do NOT 

operate immediately. Stand in the correct position or location and wait 1 to 2 days prior 
to operating. 

d.  When filling the liquid tank, ensure liquid does not enter the instrument casing. 
e.  The liquid must cover the evaporator. 
f.  Use an appropriate liquid for desired temperature range 
g.  When the liquid is water, pay close attention to the temperature set point to prevent Icing 
h.  Do not mix liquids 
i. 

DANGER! 

Do NOT use flammable

 

liquids

Use of such is

 

classified as ‘improper use’ of 

the instrument. 

j.  Tighten hose connections securely. 
k.  During continuous operation, the connection between the bath cover and the circulation 

pump may become very cold. When touching these areas ensure suitable PPE is being 
worn. 

l.  Do not transport the instrument with liquid inside the tank due to the potential of liquid 

ingress into the instrument. 

m. 

Use only clean liquids

 to prevent sediment or solids entering the cooling system and 

damaging the instrument. 
 

 

 

Содержание 10303001

Страница 1: ...User Manual Version 1 0 1 10303001 10303002 10303003 Aquilon Chiller User Manual...

Страница 2: ...ort 7 III Aquilon Introduction 8 Overview 8 IV Technical Specifications 9 V Proper Use 10 VI Inspection 10 VII Operating Instructions 11 Preparation and Precautions Prior to Use 11 7 1 User Interface...

Страница 3: ...ns certain representations of the potential dangers from the instrument or equipment Buyer is solely responsible for conducting any research necessary to learn the hazards involved for any of its inte...

Страница 4: ...trical power surges vi improper storage and handling of the Product or vii use of the Product in combination with equipment or software not supplied by the Company If the Company determines that Produ...

Страница 5: ...BE LIABLE FOR INDIRECT INCIDENTAL CONSEQUENTIAL SPECIAL OR PUNITIVE DAMAGES INCLUDING LOSS OF BUSINESS OR PROFITS UNDER ANY THEORY OF LIABILITY HEREUNDER For claims under the warranty please contact y...

Страница 6: ...not move due to vibration upon start up 11 Liquid must not enter the casing WARNING may cause property damage or personal injury 12 The working environment must be free of any flammable explosive vol...

Страница 7: ...ent or equipment or Service without charge at its sole discretion Buyer assumes sole responsibility for any reliance on or use of such assistance and information and the Company makes no warranty ther...

Страница 8: ...They are designed for continuous reliable operation When the liquid is not in use the liquid should be discharged Included are alarm functions such as timing and over temperature protection A Pt100 p...

Страница 9: ...Cooling capacity at 10 W 1200 1500 2500 Refrigerant R404A R410A Electrical performance Power Consumption W 800 1300 1600 Sensor PT100 Controller Display Type Liquid Crystal Safety protection Compresso...

Страница 10: ...rer VI Inspection Unpack the equipment carefully and check for any damage which may have arisen during transport In the event of identified damage please contact serviceusa hollandgreenscience com The...

Страница 11: ...the instrument casing e The liquid must cover the evaporator f Use an appropriate liquid for desired temperature range g When the liquid is water pay close attention to the temperature set point to p...

Страница 12: ...nd operation stops To set a timer press the SETTINGS key When the TIME value flashes enter the desired time using they arrow keys Leave at zero if a timer is not needed Silence Indicator Indicates a s...

Страница 13: ...to flash Set the desired temperature value with or keys The button allows for movement between the digits Confirm the set value with another press of button Time Settings Press the button The last va...

Страница 14: ...t Stop Cooling Operation Before the refrigeration is turned on please press key to let the liquid circulate in the pipeline in advance After setting the operating parameters press button for 4 to 5 se...

Страница 15: ...ent should be cleaned only by a clean soft rag and detergent The power must be disconnected before any maintenance or cleaning Do not clean the instrument with any corrosive cleaning solutions If the...

Отзывы: