Anti-tamper Alarm
The H-KOD 12/24 uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is
removed from the cover then the tamper alarm will operate.
PROGRAMMING
Configure the Keypad
Change the configure settings according to your application (optional). Multiple configuration settings
can be changed at one time: enter program mode, change desired settings, then exit program mode.
Set Master Code
The 6 digit Master Code is used to prevent unauthorized access to the system. To interface with the
H-KOD 12/24, the manager will need a Master Code (factory default code: 666666). We highly
recommend immediate update and recording of your Master Code.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Update Master Code
0
(
New Master Code
)
#
(
Repeat New
Master Code
)
#
3. Exit Program Mode
*
SET ACCESS CONFIGURATION
• Card or PIN (Default):
The User must present a valid Card to the H-KOD 12/24 or enter their PIN code
followed by the # key, in order to be granted access.
• Card + PIN:
The User must first present a valid Card to the H-KOD 12/24 and then enter their PIN code
followed by the # key, in order to be granted access.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Card or PIN
Zone 1
Zone 2
OR
2. Card + PIN
Zone 1
Zone 2
4 1 0 #
4 2 0 #
4 1 1 #
4 2 1 #
3. Exit Program Mode
*
User Settings
To enter the programming mode
* Master code #
To exit from the programming mode
*