Remove the upper cover with an anti-clockwise twist (img. 1).
Connect the power and the load according to the wiring diagram (img. 2).
Fix the bottom on the selected position with the inflated screw (img. 1).
Reattach the upper cover to the motion sensor. You can now power on the device and test it.
Turn the TIME knob anti-clockwise to the minimum setting (10s). Turn the LUX knob clockwise to
the maximum setting (sun) (img. 3).
Switch on the power. After a warm-up time of 30 seconds, the motion sensor will start operation.
When the sensor receives the induction signal, the connected lamp will turn on. If the motion
sensor receives no further induction signal, the load stops working within 10 seconds (±3
seconds) and the connected lamp will turn off.
Turn the LUX knob anti-clockwise to the minimum setting (3). If the ambient light is more than
3LUX, the motion sensor will not activate and the connected lamp will not turn on. If the ambient
light is less than 3LUX, the motion sensor will activate. In no induction signal is present, the
motion sensor will deactivate within 10 seconds (±3 seconds) (img. 3).
INSTALLATION MANUAL
1
2
3
4
5
6
7
TECHNICAL SPECIFICATION
DETECTION RANGE:
360°
VOLTAGE:
110-240V/AC
FREQUENCY:
50/60Hz
RATED LOAD:
400W (220-240V/AC) & 200W (110-130V/AC) (Incandescent lamp)
200W (220-240V/AC) & 100W (110-130V/AC) (Energy-saving lamp & LED lamp)
DETECTION DISTANCE:
max. 8m (<24°)
TIME DELAY:
10sec ± 3sec to 7min ± 2min (adjustable)
AMBIENT LIGHT:
<3-2000LUX (adjustable)
INSTALLATION HEIGHT:
2.2-4m
4