1 ~ 15V
1 ~ 30V
60A
30A
60A
30A
5A
3A
40mVp-p
0.1% + 5mV
0.05% + 3mV
200~240VAC / 50Hz ( or on request )
>85%
>0.97 at optimal load
3 digit LED display
+/-1% + 1 count
Green LED for power on/off indication
Red LED for overload/short circuit indication
Remote Control & Remote Sensing
Variable Speed thermal static control fan
0 ~ 40 Degree C
Overload (Constant Current Limiting), Short Circuit,
OTP (Over Temperature Protection) & OVP (Over Voltage Protection)
CE-EMC: EN 55022 CE-LVD:EN 60950
220x110x360mm
4.9Kg
4.5 REMOTE ON/OFF
The remote on/off can be activated in any mode – Normal or Remote. By default, pins 7 and 8 are open
and the output is on. Shorting pins 7 and 8 turns the output off.
5. SPECIFICATIONS
Variable Output Voltage
Total Rated Output Current
(Main + Auxiliary Output)
Rated Output Current (Main)
Rated Output Current (Auxiliary)
Ripple and Noise
Load Regulation
Line Regulation
Input Voltage
Efficiency
Dynamic Power Factor Correction
Voltmeter and Ammeter Display
Meter Accuracy
Indicator
SPS-9600
SPS-9602
Special Feature
Cooling Method
Operating Temperature
Protection
Approvals
Dimensions (WxHxD)
Weight
Remote Socket Pin Assignment
PIN
FUNCTIONS
REMARKS
1
Internal DC +5V
Maximum 50mA
2
Voltage Adjust (V)
0 ~ 5V
3
Ground
4
N.A.
5
N.A.
6
N.A.
7
Output OFF (-)
Open-circuit 5VDC
8
Output OFF (+)
Short-circuit 1.6mA