Страница 1: ...IFD E Exd Explosion Proof Flame Detector User Manual...

Страница 2: ...vapour is or may be present intermittently or as a result of an accident These are defined as hazardous areas by EN 60079 0 formally EN 50014 Electrical apparatus for explosive gas atmospheres General...

Страница 3: ...usceptible to fire damp Group II Electrical apparatus for places with a potentially explosive atmosphere other than mines susceptible to fire damp These flame detectors are designed to meet the requir...

Страница 4: ...level of protection in which explosive atmosphere mixture of air and gases vapours or mist are likely to occur 1 3 normal level of protection in which explosive atmosphere mixtures of air and gases v...

Страница 5: ...re approved IIC for listed gases in EN 50014 Table 4 Subdivisions of Group II Gases Temperature Class Referred to ambient of 20 C to 40 C Maximum Surface Temperature T6 85 C T5 100 C T4 135 C T3 200 C...

Страница 6: ...sources by responding only to low frequency flickering produced by flames typically 1 to 15Hz The detectors ignore fixed light sources and rapidly flickering illumination predominantly produced by li...

Страница 7: ...esigned manner It is recommended that it should be at least once a year 1 External surfaces of the enclosure should be periodically cleaned to ensure dust deposits are not allowed to accumulate 2 Chec...

Страница 8: ...damage during installation Any such damage can destroy the validity of the enclosure 3 Before the cover is refitted the flame path threaded joint between cover and body must be thoroughly wiped clean...

Страница 9: ...Hochiki Europe UK Ltd 9 2 3 0 810 ISS3 SEP14 Enclosure with Front Cover Removed...

Страница 10: ...onal installation requirements for example to EN 60079 14 NOTE 4 If required a loading resistor or end of line device EOL can be connected between the detector terminals of any circuit The total power...

Страница 11: ...Hochiki Europe UK Ltd 11 2 3 0 810 ISS3 SEP14 Hochiki CHQ Module Connection Information Fig 10 Connection Diagram using a CHQ SZM Single Zone Monitor or CHQ MZ...

Страница 12: ...12 Hochiki Europe UK Ltd 2 3 0 810 ISS3 SEP14 Fig 11 Connection Diagram using a CHQ DIM Dual Input Module or CHQ S...