Press the Start button on the RX3000 station to begin 
logging. 

WARNING:

 If you inadvertently install modules while the power 

is on, you must disconnect and then reconnect the battery and 
charging device to guarantee proper operation. In addition, if 
you did not plug the manager mote into the module while the 
power was off, it may not be recognized by the station. 
Disconnect and reconnect the battery and charging device. 

The station is ready for motes to be added to the network. 
Make sure the mote is in a vertical, upright position and within 
range of the station while they join the network. Refer to the 
specific sensor mote or repeater manual for details on adding 
motes. Note that once all motes are added to the network, the 
total channel count on the RX3000 station LCD for the RXW 
Manager module will represent all measurement channels plus 
a battery channel for each mote in the RX Wireless Sensor 
Network.  

See the HOBOlink Help for details on how to change the logging 
and connection intervals, view data, check mote status, add the 
mote to a map, and more. 

When the station is deployed, make sure that the RXW 
Manager cable and all other cables and wires are routed 
through weatherproof cable channels. Refer to the RX3000 
manual at www.onsetcomp.com/manual/rx3000

 

for details on 

using the weatherproof cable channel. 

Deployment and Mounting 

 

Use cable ties or screws to mount the mote via the holes 

on the mounting tabs. 

 

Make sure the mote remains in a vertical position once it is 

placed in its deployment location for optimal network 
communications. 

 

Make sure the mote door is closed, with both latches fully 

locked to ensure a watertight seal. 

 

Consider using a 3/16 inch padlock to restrict access to the 

mote. With the mote door closed, hook a padlock through 
the eyelet on the right side of the door and lock it. 

 

Mount the manager as high as possible above the RX3000 

station to increase the radio signal and line of sight. 

Tips for Setting up the RX Wireless Sensor 
Network 

 

Stay close to the RX3000 station when adding motes to 
the wireless network because you will need to access both 
the station and the mote at the same time. After the mote 
has successfully joined the wireless network, you can then 
move it to its deployment location. 

 

Check the signal strength on the mote LCD on the location 
where you want to place the mote. If there is only one or 
two bars on the signal strength indicator, consider moving 
the mote to a location where the signal strength is stronger. 

 

Make sure motes are mounted a minimum of 1.8 m (6 
feet) above the ground or vegetation to help maximize 
distance and signal strength as shown below. 

 

 

Consider using a plastic pole such as PVC to mount the 

motes. 

 

Make sure each sensor mote and repeater is positioned so 

that the built-in solar panel receives optimal sunlight 
throughout each season as shown below. It may be 
necessary to periodically adjust the mote position as the 
path of the sunlight changes throughout the year or if tree 
and leaf growth alters the amount of sunlight reaching the 
solar panel. 

 

 

Obstructions between motes can prevent reliable network 
communication. If the mote is blocked by a small 
obstruction (e.g. a pole, the RX3000 station, shrubbery), 
then move the mote to a location where the obstruction is 
not blocking the path to the nearest mote. If there is a 
change in elevation between motes or a large obstruction 
is in the way (e.g. a building or tree), then either 
reposition the mote until there is full line of sight to the 
next mote or add a repeater between them. 

 