background image

HOBO

 

MX

 

Soil

 

Moisture

 

(MX2306)

 

and

 

MX

 

Soil

 

Moisture

 

and

 

Temperature

 

(MX2307)

 

Data

 

Logger

 

Manual

 

1

508

759

9500

 

(U.S.

 

and

 

International)

 

2

 

www.onsetcomp.com

 

1

800

LOGGERS

 

(U.S.

 

only)

 

Time

 

Accuracy

 

±1

 

minute

 

per

 

month

 

 

to

 

50°C

 

(32°

 

to

 

122°F)

 

Battery

 

Type

 

2/3

 

AA

 

3.6

 

Volt

 

lithium,

 

user

 

replaceable

 

Battery

 

Life

 

2

 

years,

 

typical

 

with

 

logging

 

interval

 

of

 

1

 

minute

 

and

 

Bluetooth

 

Always

 

On

 

enabled;

 

5

 

years,

 

typical

 

with

 

logging

 

interval

 

of

 

1

 

minute

 

and

 

Bluetooth

 

Always

 

On

 

disabled.

 

Faster

 

logging

 

intervals

 

and

 

statistics

 

sampling

 

intervals,

 

burst

 

logging,

 

remaining

 

connected

 

with

 

the

 

app,

 

excessive

 

downloads,

 

and

 

paging

 

may

 

impact

 

battery

 

life.

 

Memory

 

110,000

 

measurements,

 

maximum

 

(472

 

KB)

 

Full

 

Memory

 

Download

 

Time

 

Approximately

 

60

 

seconds;

 

may

 

take

 

longer

 

the

 

further

 

the

 

device

 

is

 

from

 

the

 

logger

 

Dimensions

 

Logger

 

housing:

 

10.8

 

x

 

5.08

 

x

 

2.24

 

cm

 

(4.25

 

x

 

2.0

 

x

 

0.88

 

in.)

 

Soil

 

moisture

 

sensor:

 

7.5

 

x

 

5.1

 

x

 

2.4

 

cm

 

(2.95

 

x

 

2.02

 

x

 

0.95

 

inches)

 

Soil

 

moisture

 

sensor

 

needle

 

length:

 

5.4

 

cm

 

(2.13

 

inches)

 

Soil

 

moisture

 

sensor

 

needle

 

diameter:

 

0.32

 

cm

 

(0.13

 

inches)

 

Temperature

 

sensor

 

(MX2307)

 

diameter:

 

0.53

 

cm

 

(0.21

 

in.)

 

Sensor

 

cable

 

length:

 

2

 

m

 

(6.56

 

ft)

 

Weight

 

MX2306:

 

229

 

g

 

(80

 

oz)

 

MX2307:

 

267

 

g

 

(94

 

oz)

 

Materials

 

Logger:

 

Acetal,

 

silicone

 

gasket,

 

stainless

steel

 

screws

 

Soil

 

Moisture

 

Sensor:

 

ASA

 

plastic

 

body

 

with

 

polyurethane

 

epoxy

 

filling

 

and

 

stainless

steel

 

pins

 

Temperature

 

Sensor

 

(MX2307):

 

Stainless

steel

 

waterproof

 

tip

 

Cable:

 

PVC,

 

UV

 

resistant

 

and

 

rodent

 

repellent

 

(soil

 

moisture

 

sensor

 

cable)

 

Environmental

 

Rating

 

Logger:

 ‐

25

 

to

 

60°C

 

(

13

 

to

 

140°F);

 

weatherproof;

 

NEMA

 

6

 

and

 

IP67

 

Soil

 

Moisture

 

sensor

 

and

 

cable:

 ‐

40

 

to

 

60°C

 

(

40

 

to

 

140°F)

 

Temperature

 

sensor

 

and

 

cable

 

(MX2307):

 

Immersion

 

in

 

water

 

up

 

to

 

50°C

 

(122°F)

 

for

 

1

 

year

 

 

The

 

CE

 

Marking

 

identifies

 

this

 

product

 

as

 

complying

 

with

 

all

 

relevant

 

directives

 

in

 

the

 

European

 

Union

 

(EU).

 

 

 

The

 

UKCA

 

marking

 

identifies

 

this

 

product

 

as

 

complying

 

with

 

all

 

relevant

 

directives

 

in

 

the

 

UK

 

Declaration

 

of

 

Conformity.

 

 

  

See

 

last

 

page

 

*For

 

additional

 

accuracy,

 

t

he

 

sensor

 

data

 

can

 

be

 

post

calibrated

 

for

 

a

 

particular

 

soil

 

by

 

applying

 

a

 

calibration

 

equation

 

to

 

the

 

data

 

exported

 

from

 

the

 

app.

 

Logger

 

Components

 

and

 

Operation

 

 

 

Mounting

 

Holes:

 

Use

 

the

 

holes

 

at

 

the

 

top

 

and

 

bottom

 

of

 

the

 

logger

 

to

 

mount

 

it

 

(see

 

Deploying

 

and

 

Mounting

 

the

 

Logger

).

 

Alarm

 

LED:

 

This

 

LED

 

blinks

 

red

 

every

 

4

 

seconds

 

when

 

an

 

alarm

 

is

 

tripped

 

(unless

 

Show

 

LED

 

is

 

disabled

 

as

 

described

 

in

 

Configuring

 

the

 

Logger

).

 

Status

 

LED:

 

This

 

LED

 

blinks

 

blue

 

every

 

4

 

seconds

 

when

 

the

 

logger

 

is

 

logging

 

(unless

 

Show

 

LED

 

is

 

disabled

 

as

 

described

 

in

 

Configuring

 

the

 

Logger

).

 

If

 

the

 

logger

 

is

 

waiting

 

to

 

start

 

logging

 

because

 

it

 

was

 

configured

 

to

 

start

 

“On

 

Button

 

Push”

 

or

 

with

 

a

 

delayed

 

start,

 

it

 

will

 

blink

 

every

 

8

 

seconds.

 

Start

 

Button:

 

Press

 

this

 

button

 

to

 

wake

 

up

 

the

 

logger;

 

both

 

the

 

alarm

 

and

 

status

 

LEDs

 

will

 

blink.

 

Once

 

the

 

logger

 

is

 

awake,

 

press

 

this

 

button

 

to

 

move

 

it

 

to

 

the

 

top

 

of

 

the

 

devices

 

list

 

in

 

the

 

app.

 

Press

 

this

 

button

 

for

 

3

 

seconds

 

to

 

start

 

or

 

stop

 

the

 

logger

 

when

 

it

 

is

 

configured

 

to

 

start

 

or

 

stop

 

“On

 

Button

 

Push”

 

(see

 

Configuring

 

the

 

Logger

).

 

Both

 

LEDs

 

will

 

blink

 

four

 

times

 

when

 

you

 

press

 

the

 

button

 

to

 

start

 

or

 

stop

 

logging.

 

Press

 

this

 

button

 

for

 

10

 

seconds

 

to

 

reset

 

a

 

password

 

(see

 

Setting

 

a

 

Password

).

 

MX2307

 

model

 

shown

 

Alarm

 

LED

 

Mounting

 

Holes

 

Start

 

Button

 

External

 

Sensor

 

Status

 

LED

 

Содержание MX2306

Страница 1: ...Hz Volume of Influence 430 ml Percent of Field Capacity for VWC measurements only Range 0 to 200 Resolution 0 1 Temperature Sensor MX2307 Range 40 to 100 C 40 to 212 F with tip and cable immersion in...

Страница 2: ...NEMA 6 and IP67 Soil Moisture sensor and cable 40 to 60 C 40 to 140 F Temperature sensor and cable MX2307 Immersion in water up to 50 C 122 F for 1 year The CE Marking identifies this product as comp...

Страница 3: ...com products software hoboconnect 2 Open the app and enable Bluetooth in the device settings if prompted 3 Press the button on the logger to wake it up 4 Tap Devices and then tap the logger in the ap...

Страница 4: ...ion settings are loaded on the logger The data will start with this indetermined time and at the selected logging interval from there On Next Logging Interval This is the most common start option Logg...

Страница 5: ...n any time during logging For example if the low alarm is set to 0 05 m m for a soil moisture alarm and the duration is set to 30 minutes the alarm will trip once the sensor readings have been below 0...

Страница 6: ...g During fixed logging the logger records data for enabled sensors and or selected statistics at the logging interval selected Statistics are calculated at a sampling rate you specify with the results...

Страница 7: ...ger records the following internal events to track logger operation and status You can view events in exported files or plot events in the app To plot events tap HOBO Files and select a file to open T...

Страница 8: ...the sensor body in a horizontal position will provide measurements at a more discreet depth Avoid any metal located between the sensor and the ferrite core because it can interfere with VWC measuremen...

Страница 9: ...not cut open incinerate heat above 85 C 185 F or recharge the lithium battery The battery may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery c...