background image

 

HOBO Pendant MX Temp (MX2201) and Temp/Light (MX2202) Logger Manual 

1-800-LOGGERS 8 

www.onsetcomp.com 

logging. Deployments in extremely cold or hot temperatures or 
a logging interval faster than one minute can impact battery 
life. Estimates are not guaranteed due to uncertainties in initial 
battery conditions and operating environment. 

To replace the battery: 

1.

 

While pushing down with both thumbs on the back of the 
logger, rotate the battery cover counterclockwise until it 
stops moving (about a 1/8 turn). 

 

2.

 

Use the edge below the arrow on the cover to lift it off the 
logger. 

 

3.

 

Remove the battery and place a new one in the battery 
holder, positive side facing up. Use a small flat-head 
screwdriver to carefully pop the battery out of its holder as 
shown. 

 

4.

 

Inspect the O-ring on the battery cover. Make sure it is 
clean and seated properly. Remove any dirt, lint, hair, or 
debris from the O-ring. If the O-ring has any cracks or tears, 
replace it as follows: 

a.

 

Spread a small dot of silicone-based grease on the O-
ring with your fingers, making sure the entire O-ring 
surface is completely covered in grease. 

b.

 

Place the O-ring on the cover and clean off any debris. 
Make sure the O-ring is fully seated and level in the 
groove and not pinched or twisted. This is necessary to 
maintain a waterproof seal. 

5.

 

Place the cover back on the logger as shown, aligning the 
notches in the cover with the rounded tabs on the logger 
case. The cover will not close properly and maintain a 
waterproof seal if it is misaligned. 

 

6.

 

While pushing down with both thumbs, rotate the battery 
cover clockwise until it locks in position under the two large 
corner tabs and the two small rounded tabs. 

 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium battery. The battery may 
explode if the logger is exposed to extreme heat or conditions 
that could damage or destroy the battery case. Do not dispose 
of the logger or battery in fire. Do not expose the contents of 
the battery to water. Dispose of the battery according to local 
regulations for lithium batteries.

 

 

 

 

Use this edge to 
lift the cover off 

Align notch in cover with 
small, rounded tab on logger 

Cover secured under 
rounded tab 

Cover secured 
under corner tab 

Cover secured 
under corner tab 

Cover secured under 
rounded tab 

Align notch in cover with 
small, rounded tab on logger 

Содержание MX2201

Страница 1: ...7 oz positive Waterproof To 30 5 m 100 ft Radio Power 1 mW 0 dBm Transmission Range Approximately 30 5 m 100 ft line of sight Wireless Data Standard Bluetooth Low Energy Bluetooth Smart Logging Rate 1 second to 18 hours Time Accuracy 1 minute per month at 25 C 77 F Battery CR2032 3V lithium user replaceable Battery Life 1 year typical at 25 C 77 F with logging interval of 1 minute and Bluetooth Al...

Страница 2: ...ote The circle on the front of the logger represents the button area on the logger You will not feel an actual button push when you press that area this is normal Light Measurement MX2202 The logger measures light intensity in units of lumens ft2 or lux The light sensor in the MX2202 has a spectral response that tightly matches the photopic response of the human eye This is shown in Plot A The lig...

Страница 3: ...connected to the device during the upgrade Configuring the Logger Use the app to set up the logger including selecting the logging interval start and stop logging options and configuring alarms These steps provide an overview of setting up the logger For complete details see the app user s guide 1 Tap Devices and then tap the logger to connect to it If the logger was configured with Bluetooth Alwa...

Страница 4: ...he selected duration For example the high alarm is set to 85 F and the duration is set to 30 minutes then the alarm will only trip if all sensor readings are 85 F or above for a continuous 30 minute period 7 Tap Save and repeat steps 3 7 for the other sensor if desired Note that when both alarms are configured an alarm is raised when either sensor is in an alarm condition 8 In the configuration se...

Страница 5: ...or each sensor The maximum or highest sampled value The minimum or lowest sampled value An average of all sampled values and The standard deviation from the average for all sampled values For example a Pendant MX Temp Light MX2202 logger is configured with both the temperature and light sensors enabled and the logging interval set to 5 minutes The logging mode is set to fixed interval logging with...

Страница 6: ...nts in exported files or plot events in the app To plot events tap HOBO Files and select a file to open Tap and then tap Select the events you want to plot and tap OK Event Name Definition Host Connect The logger was connected to a mobile device Started The logger started logging Stopped The logger stopped logging Chan Alarm Tripped Cleared An alarm has occurred because the reading was outside the...

Страница 7: ...X2202 logger is mounted horizontally so that the light sensor is pointing straight up towards the sky as shown in this example Be careful of solvents Check a materials compatibility chart against the wetted materials listed in the Specifications table before deploying the logger in locations where untested solvents are present The logger has an EPDM O ring which is sensitive to polar solvents acet...

Страница 8: ...ace is completely covered in grease b Place the O ring on the cover and clean off any debris Make sure the O ring is fully seated and level in the groove and not pinched or twisted This is necessary to maintain a waterproof seal 5 Place the cover back on the logger as shown aligning the notches in the cover with the rounded tabs on the logger case The cover will not close properly and maintain a w...

Страница 9: ...an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired...

Отзывы: