RXW Temperature Sensor (RXW-TMB-xxx) Manual 

1-800-LOGGERS 

www.onsetcomp.com 

Adding the Mote to the HOBOnet Wireless 

Sensor Network 

The mote must join a HOBOnet Wireless Sensor Network 

before it can begin measuring temperature and transmitting 

data. This requires accessing the station and the mote at the 

same time so it is recommended that you complete these steps 

before deploying the mote. 

Important: 

If you are setting up a new station, follow the 

instructions in the station quick start before setting up this 

mote (go to www.onsetcomp.com/support/manuals/24380-

man-rx2105-rx2106-qsg for RX2105 and RX2106 stations or go 

to www.onsetcomp.com/support/manuals/18254-MAN-QSG-

RX3000 for RX3000 stations).

 

To add a mote to the network: 
1.

 

If the LCD is blank on the station, press any button to wake 

it up. 

2.

 

Press the Select button once (which shows the number of 

smart sensors installed) and then press it again to switch to 

the module with the manager (module 2 on RX2105 or 

RX2106 stations). 

 

3.

 

Press the Search button (the magnifying glass). The 

magnifying glass icon will blink while the station is in search 

mode. 

 

4.

 

Open the mote door and install the batteries if you have not 

already done so. 

5.

 

Press the button on the mote for 3 seconds. The signal 

strength icon will flash and then cycle. 

 

6.

 

Watch the LCD on the mote. 

 

 

 

 

 

This process may take up to five minutes. The green LED 

blinks quickly while the mote searches for a network to join 

and then blinks slowly while it completes the network 

registration. Once the mote has finished joining the 

network, the green LED turns off and the blue LED then 

blinks indefinitely while the mote is part of the network. 

Note:

 If the mote cannot find the network or has trouble 

remaining connected during this process, make sure the 

mote is in a vertical, upright position and within range of 

the station. 

7.

 

Press the Search button (the magnifying glass) on the 

station to stop searching for motes. 

 

If you added more than one more mote to the network, then 

the total channel count on the station LCD for the manager 

module will represent all measurement channels plus a battery 

channel for each mote in the network. 
Sensor measurements will be recorded at the logging interval 

specified in HOBOlink, transmitted to the station, and uploaded 

to HOBOlink at the next connection interval (readout). Use 

HOBOlink to monitor mote status and health. If a mote is 

temporarily offline, any logged data is saved until it is back 

online. In addition, if a mote is offline for 30 minutes, the 

station will automatically connect to HOBOlink and report the 

mote as missing. Once the mote is back online, any logged data 

will be uploaded the next time the station connects to 

HOBOlink. 

Press this button to view the module 

Press this button for 3 

seconds for the mote to 

join the network 

Press this button again to 

stop searching for motes 

Press this button so the station is ready 

to have motes join the network 

This signal strength icon 

blinks while searching for 

a network. 

Once a network is found, 

the icon will stop flashing 

and the bars will cycle from 

left to right. 

c. 

d. 

This network connection 

“x” icon blinks while the 

mote completes the 

registration process. 

which may take up to 

five minutes. 

Once the mote has finished joining 

the network, the “x” icon is 

removed and the channel count 

on the station LCD increases by 

two (one for temperature and one 

for the mote battery). 

a. 

b. 