background image

Warranty Questions?

Call
1-877-HOBART1
for your local
Hobart distributor.

hobart retail 8/03

Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.

Support
Need fast answers to the
tough welding questions?
Contact your distributor or
call 1-800-332-3281. The
expertise of the distributor
and Hobart is there to
help you, every step of
the way.

Effective January 1, 2003

5/3/1 WARRANTY applies to all Handler 125, 135 and 175 models, Airforce 250, 250A, 375, 400

and 625 models, and Champion 4500 and 10,000 models, Beta-Mig 1800, Champ 1435, 2060, 8500

models, Ironman 210 and 250 models, Stickmate models, Tigmate models, and HSW-15 and

HSW-25 spot welder models effective with Serial No. KK200262 and newer.

This limited warranty supersedes all previous Hobart warranties and is exclusive with

no other guarantees or warranties expressed or implied.

Hobart products are serviced by Hobart or Miller Authorized Service Agencies.

LIMITED WARRANTY − Subject to the terms and conditions
below, Hobart/Miller Electric Mfg. Co., Appleton, Wisconsin,
warrants to its original retail purchaser that new Hobart
equipment sold after the effective date of this limited warranty is
free of defects in material and workmanship at the time it is
shipped by Hobart. THIS WARRANTY IS EXPRESSLY IN LIEU
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
FITNESS.

Within the warranty periods listed below, Hobart/Miller will repair
or replace any warranted parts or components that fail due to
such defects in material or workmanship. Hobart/Miller must be
notified in writing within thirty (30) days of such defect or failure, at
which time Hobart/Miller will provide instructions on the warranty
claim procedures to be followed.

Hobart/Miller shall honor warranty claims on warranted
equipment listed below in the event of such a failure within the
warranty time periods. All warranty time periods start on the date
that the equipment was delivered to the original retail purchaser,
or one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.

1.

5 Years — Parts and Labor

*

Original Main Power Rectifiers

*

Transformers

*

Stabilizers

*

Reactors

2.

3 Years — Parts and Labor

*

Drive Systems

*

PC Boards

*

Rotors, Stators and Brushes

*

Idle Module

*

Solenoid Valves

*

Switches and Controls

*

Spot Welder Transformer

3.

1 Year — Parts and Labor Unless Specified
(90 days for industrial use)

*

Motor-Driven Guns

*

MIG Guns/TIG Torches

*

Relays

*

Contactors

*

Regulators

*

Water Coolant Systems

*

Flowgauge and Flowmeter Regulators (No Labor)

*

HF Units

*

Running Gear/Trailers

*

Plasma Cutting Torches

*

Remote Controls

*

Replacement Parts (No labor)

*

Accessories

*

Field Options
(NOTE: Field options are covered

 

for the remaining

warranty period of the product they are installed in, or
for a minimum of one year — whichever is greater.)

4.

Engines, batteries and tires are warranted separately by the
manufacturer.

Hobart’s 5/3/1 Limited Warranty shall not apply to:

1.

Consumable components such as contact tips, cutting
nozzles, slip rings, drive rolls, gas diffusers, plasma
torch tips and electrodes, weld cables, and tongs and
tips, or parts that fail due to normal wear. 
(Exception:
brushes, slip rings, and relays are covered on Hobart
Engine-Driven models.)

2.

Items furnished by Hobart/Miller, but manufactured by
others, such as engines or trade accessories. These items
are covered by the manufacturer’s warranty, if any.

3.

Equipment that has been modified by any party other than
Hobart/Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.

HOBART PRODUCTS ARE INTENDED FOR PURCHASE AND
USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS
TRAINED AND EXPERIENCED IN THE USE AND
MAINTENANCE OF WELDING EQUIPMENT.

In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Hobart’s/Miller’s option: (1) repair;
or (2) replacement; or, where authorized in writing by
Hobart/Miller in appropriate cases, (3) the reasonable cost of
repair or replacement at an authorized Hobart/Miller service
station; or (4) payment of or credit for the purchase price (less
reasonable depreciation based upon actual use) upon return of
the goods at customer’s risk and expense. Hobart’s/Miller’s
option of repair or replacement will be F.O.B., Factory at
Appleton, Wisconsin, or F.O.B. at a Hobart/Miller authorized
service facility as determined by Hobart/Miller. Therefore no
compensation or reimbursement for transportation costs of any
kind will be allowed.

TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL HOBART/MILLER BE
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.

ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND
ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION,
MIGHT ARISE BY IMPLICATION, OPERATION OF LAW,
CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO
ANY AND ALL EQUIPMENT FURNISHED BY
HOBART/MILLER IS EXCLUDED AND DISCLAIMED BY
Hobart/Miller.

Some states in the U.S.A. do not allow limitations of how long an
implied warranty lasts, or the exclusion of incidental, indirect,
special or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty provides specific
legal rights, and other rights may be available, but may vary from
state to state.

In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations and
exclusions set out above may not apply. This Limited Warranty
provides specific legal rights, and other rights may be available,
but may vary from province to province.

Содержание STICKMATE LX

Страница 1: ...225 AC DC And 225 AC Processes Description Arc Welding Power Source OM 316 087 083N October 2003 Stick SMAW Welding AC Models AC DC Models STICKMATE LX R Visit our website at www HobartWelders com ...

Страница 2: ... take time to read the Safety precautions They will help you protect yourself against potential hazards on the worksite We ve made installation and operation quick and easy With Hobart you can count on years of reliable service with proper maintenance And if for some reason the unit needs repair there s a Troubleshooting section that will help you figure out what the problem is The parts list will...

Страница 3: ... 14 3 7 Electrical Service Guide 15 3 8 Internal Connections For Operating 115 230 Volts 225 Amperes AC And AC DC Models From 115 Volts 16 3 9 Internal Connections For Operating 230 400 Volts 300 200 Amperes AC DC Or 300 Amperes AC Mod els From 230 Volts 17 3 10 Connecting Input Power 18 SECTION 4 OPERATION 19 4 1 Controls 19 SECTION 5 MAINTENANCE TROUBLESHOOTING 21 5 1 Routine Maintenance 21 5 2 ...

Страница 4: ......

Страница 5: ...nnect box or that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power cord for damage or bare wiring replace cord immediately if damaged bare wiring can kill D Turn off all equipment when not in use D Do not use worn damaged undersized or poorly spliced cab...

Страница 6: ...r or cut off welding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane lighter or matches from your person before doing any welding FLYING METAL can injure eyes D Welding chipping wire brushing and grinding cause sparks and flying metal As welds cool they can t...

Страница 7: ...nsible for having a qualified electrician prompt ly correct any interference problem resulting from the installa tion D If notified by the FCC about interference stop using the equipmentat once D Have the installation regularly checked and maintained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibi...

Страница 8: ...02269 9101 phone 617 770 3000 website www nfpa org and www sparky org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart J from U S Government Printing Office Super intendent of Documents P O Box 371954 Pittsburgh PA 15250 there are 10 Regional Offices phone for Region 5 Chicago is 312 353 2220 webs...

Страница 9: ...ordon d alimentation est bien raccordé à la borne de terre du sectionneur ou que la fiche du cordon est raccordée à une prise correctement mise à la terre D Pour exécuter les branchements d entrée fixer d abord le conducteur de mise à la terre adéquat et contre vérifier les connexions D Vérifier fréquemment le cordon d alimentation et s assurer qu il n est ni endommagé ni dénudé le remplacer imméd...

Страница 10: ...empts d huile tels que des gants en cuir une chemise en tissu épais des pantalons sans revers des chaussures montantes et un masque D Avant de souder retirer tout produit combustible de ses poches tel qu un briquet au butane ou des allumettes LES PARTICULES PROJETÉES peu vent blesser les yeux D Le soudage le burinage le passage de la pièce à la brosse métallique et le meulage provoquent l émission...

Страница 11: ...ouvrements et dispositifs de protection LE RAYONNEMENT HAUTE FRÉ QUENCE H F risque de causer des interférences D Le rayonnement haute fréquence peut causer des interférences avec les équipements de radio navigation et de communication les services de sécurité et les ordinateurs D Ne demander qu à des personnes qualifiées familiarisées avec les équipements électroniques de faire fonctionner l insta...

Страница 12: ...ealth Standards for General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart J de l U S Government Printing Office Super intendent of Documents P O Box 371954 Pittsburgh PA 15250 il y a 10 bureaux régionaux Téléphone pour la Région 5 Chicago 312 353 2220 site Web www osha gov 2 5 Information sur les champs électromagnétiques Données sur le soudage électr...

Страница 13: ... 80 VAC 70 67 39 34 134 lbs 61 kg DC 200 A 25 Volts DC 20 Duty Cycle 50 60 Hz 30 200 80 VDC 70 5 4 67 3 6 39 1 8 34 1 3 134 lbs 61 kg Overall Dimensions Height 18 3 4 in 476 mm Width 12 3 4 in 323 mm Depth 17 1 2 in 445 mm While idling AC Models Rated Welding Output Amperage Range Max Open Circuit Voltage Amperes Input at Rated Load Output 50 Or 60 Hz Single Phase Weight Rated Welding Output Range...

Страница 14: ...dels 300 200 Amperes A For 115 230 230 And 460 Volt Models 225 150 Amperes These models have a 15 duty cycle when used with 50 Hz input power 2 Minutes Welding 8 Minutes Resting B For AC Models ST 001 836 A SB 099 603 A Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating Y 20 Duty Cycle at 225 Amperes Ex ceeding duty cycle can damage unit and void warranty B...

Страница 15: ... shown A For 115 230 230 And 460 Volt Models 225 150 Amperes B For 220 230 400 And 460 Volt Models 300 200 Amperes 0 10 20 30 40 50 60 70 80 90 100 0 100 200 300 400 DC Amperes DC Volts MIN MAX 0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400 450 AC Amperes A LOW RANGE B HIGH RANGE A A B B 0 10 20 30 40 50 60 70 80 0 50 100 150 200 250 DC Amperes DC Volts 0 10 20 30 40 50 60 70 80...

Страница 16: ...es shown A For 115 230 And 230 Volt Models 225 Amperes B For 220 Volt Model 300 Amperes C For 230 400 Volt Model 300 Amperes 0 10 20 30 40 50 60 70 80 90 0 100 200 300 400 500 AC Amperes AC Volts 0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 350 400 450 AC Amperes AC Volts A LOW RANGE B HIGH RANGE A A B B 0 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300 AC Amperes AC Volts A LOW R...

Страница 17: ...electing A Location Ref ST 151 556 ST 802 105 C 1 Rating Label Locate unit near correct input power Y Special installation may be required where gasoline or volatile liquids are present see NEC Article 511 or CEC Section 20 18 in 457 mm for airflow 1 ...

Страница 18: ...it Has Bare Conductors on End 6 Terminal Screw Back out terminal screw from elec trode holder Insert electrode cable through barrel into end of electrode holder and tighten terminal screw securely Move barrel toward electrode hold er and tighten set screw to secure barrel in place Installing Work Cable onto Work Clamp 7 Work Clamp 8 Work Cable From Unit Has Ring Terminal on End 9 Mounting Bolt Rou...

Страница 19: ...ircuit Breaker Rating In Amperes 150 110 70 100 60 35 50 Min Input Conductor Size In AWG Kcmil 8 8 12 10 14 14 14 Max Recommended Input Conductor Length In Feet Meters 32 10 75 23 87 26 82 25 101 31 138 42 87 27 Min Grounding Conductor Size In AWG Kcmil 8 8 12 10 14 14 14 Electrical Service Requirements For 300 200 AC DC And 300 AC Models Reference 1997 National Electrical Code NEC Ref S 0092 J ...

Страница 20: ...oosen strain relief and remove 230 volt in put power cord Obtain correct size and length 115 volt input power cord see Section 3 7 Install correct size ring terminals to cord leads Route cord through strain relief and connect green lead to ground terminal To install large power cords remove knock out located on lower rear panel of unit insert power cord and install plug into original power cord ho...

Страница 21: ...r 1 Primary Coil Lead 4 2 Lead 4 Insulation Sleeving 3 Power Switch Lead 4 4 Lead Connection Hardware Slide Sleeving down and discon nect one lead 4 from the other Re move sleeving 5 Fan Motor FM Lead 2 6 Lead 2 Insulation Sleeving Disconnect fan motor lead 2 at fan motor and remove sleeving Take lead 2 sleeving and secure it over the end of primary coil lead 4 Replace lead 2 sleeving with lead 4 ...

Страница 22: ...ting label in Section 3 4 and be sure to supply correct in put power 1 Line Disconnect Device 2 Input And Grounding Conductors For Models Not Supplied With Plug See Section 3 7 for conductor and fuse size and ratings Size and ratings must comply with applicable codes 3 Plug 4 Proper Receptacle User Supplied GND PE L1 2 3 Install conductors into a deenergized line disconnect device Y Always connect...

Страница 23: ...odels Ref ST 190 600 B ST 802 105 C 1 Amperage Adjustment Control 2 Power Switch 3 Mode Switch For DC Weld Output Use mode switch to select polarity of dc output Electrode Posi tive DCEP or Electrode Nega tive DCEN For AC Weld Output Use mode switch to select ac low range or high range output 3 1 2 ...

Страница 24: ...e 20 Return To Table Of Contents B Controls For AC Models Ref ST 190 599 A ST 802 105 C 1 Amperage Adjustment Control 2 Power Switch 3 Mode Switch Use mode switch to select ac low range or high range output 3 1 2 ...

Страница 25: ...ower source and disconnect input power 1 Wrapper Remove wrapper 2 Shunt Block Do not grease screw threads on shunt block Apply light coating of high tempera ture grease to shaded areas of both shunt blocks Turn amperage con trol handle to spread grease evenly 3 Noise Adjustment Screws If shunt block vibrates and becomes noisy tighten adjustment screws 1 4 turn Install wrapper turn On unit and chec...

Страница 26: ...on gear onto front panel making sure anti rotation pins are in holes on front panel 6 Pointer Gear Install pointer gear overtop of pinion gear and rotate so pointer is indicat ing 130 Amps on ac Low Range scale see example Install crank handle overtop the sta tor pinion gear assembly with the handle straight down It may be necessary to turn the handle slight ly so vertical alignment is possible 7 ...

Страница 27: ...hing is blocking movement of fan If fan does not run freely replace fan motor Erratic weld current Clean and tighten all weld cable connections Erratic arc with excessive spatter Use dry properly stored electrodes Shorten arc length Reduce amperage setting see Section 4 1 Electrode freezing to work Increase amperage setting see Section 4 1 Increase arc length Use dry properly stored electrodes Noi...

Страница 28: ...OM 316 Page 24 Return To Table Of Contents SECTION 6 ELECTRICAL DIAGRAMS SA 191 364 Figure 6 1 Circuit Diagram For AC DC 230 Volts Models SA 191 365 Figure 6 2 Circuit Diagram For AC DC 460 Volts Models ...

Страница 29: ...I GRN S1 1 2 3 4 CONNECTED FOR 115 VOLTS PRI T1 1 2 3 4 PLG1 FM FM S1 GRN S1 PLG1 LINE BLK NEUTRAL WHT Figure 6 3 Circuit Diagram For AC DC 115 230 Volts Models SA 191 368 220 PRI SEC T1 GRN VOLT ONLY S2 WORK ELECTRODE R Z1 SR1 S O P POWER CORD FM S1 S O P Figure 6 4 Circuit Diagram For 300 200 AC DC 220 Volts Models ...

Страница 30: ...PRI T1 GRN S1 230V 1 2 3 4 4 CONNECTED FOR 230 VOLTS PRI T1 1 3 2 POWER CORD FM FM Figure 6 5 Circuit Diagram For 300 200 AC DC 230 400 Volts Models SA 191 370 SEC T1 S O P S2 WORK ELECTRODE R Z1 SR1 S O P 460 PRI GRN VOLT ONLY 230V POWER CORD FM S1 Figure 6 6 Circuit Diagram For 300 200 AC DC 460 Volts Model ...

Страница 31: ...C LOW ELECTRODE PLG1 FM S1 Figure 6 7 Circuit Diagram For 225 230 Volts Models SA 191 361 A WORK CONNECTED FOR 230 VOLTS PRI SEC T1 GRN S2 ELECTRODE S1 1 2 3 4 CONNECTED FOR 115 VOLTS PRI T1 1 2 3 4 PLG1 FM FM GRN S1 PLG1 LINE BLK NEUTRAL WHT S1 Figure 6 8 Circuit Diagram For 225 115 230 Volts Models ...

Страница 32: ... AC LOW ELECTRODE POWER CORD FM S1 SA 191 366 Figure 6 9 Circuit Diagram For 300 220 Volts Models SA 191 367 WORK CONNECTED FOR 400 VOLTS PRI SEC T1 GRN S2 ELECTRODE S1 230V 1 2 3 4 4 CONNECTED FOR 230 VOLTS PRI T1 1 3 2 POWER CORD FM FM Figure 6 10 Circuit Diagram For 300 230 400 Volts Models ...

Страница 33: ...ess current than a large one Follow recommendations of electrode manufacturer when setting weld amperage see 7 2 4 Insulated Electrode Holder 5 Electrode Holder Position 6 Arc Length Arc length is the distance from the electrode to the workpiece A short arc with correct amperage will give a sharp crackling sound Y Welding current starts as soon as electrode touches the workpiece 7 Slag Use a chipp...

Страница 34: ...6011 6013 7014 7018 7024 Ni Cl 308L 50 100 150 200 250 300 350 400 450 ELECTRODE DC AC POSITION PENETRATION USAGE MIN PREP ROUGH HIGH SPATTER GENERAL SMOOTH EASY FAST LOW HYDROGEN STRONG SMOOTH EASY FASTER CAST IRON STAINLESS DEEP DEEP LOW MED LOW LOW LOW LOW ALL ALL ALL ALL ALL FLAT HORIZ FILLET ALL ALL EP EP EP EN EP EN EP EP EN EP EP 6010 6011 6013 7014 7018 7024 NI CL 308L EP ELECTRODE POSITIV...

Страница 35: ...ork piece use a quick twist to free it Bring electrode straight down to workpiece then lift slightly to start arc If arc goes out electrode was lifted too high If electrode sticks to workpiece use a quick twist to free it 1 2 3 1 2 3 Scratch Start Technique Tap Start Technique 7 4 Positioning The Electrode Holder S 0660 90 90 10 30 45 45 10 30 Groove Welds End View Of Work Angle Side View Of Elect...

Страница 36: ...ead 3 Moderate Crater During Welding Weld a new bead or layer for each 1 8 in 3 2 mm thickness in metals being welded 4 No Overlap 5 Good Penetration Into Base Metal 5 4 2 3 1 4 1 5 Good Weld Bead 2 3 Poor Weld Bead S 0053 A 7 6 Conditions That Affect Weld Bead Shape S 0061 Angle Too Small 10 30 Angle Too Large Correct Angle Drag Electrode Angle Too Short Normal Too Long Arc Length Slow Normal Fas...

Страница 37: ...across gaps a weave bead works better 1 2 3 7 8 Butt Joints S 0662 1 Tack Welds Prevent edges of joint from drawing together ahead of electrode by tack welding the materials in position be fore final weld 2 Square Groove Weld Good for materials up to 3 16 in 5 mm thick 3 Single V Groove Weld Good for materials 3 16 through 3 4 in 5 19 mm thick Cut bevel with oxyacetylene or plasma cutting equipmen...

Страница 38: ... of speed Hold electrode as shown to provide fusion into the corner Square edge of the weld surface For maximum strength weld both sides of upright section 3 Multi Layer Deposits Weld a second layer or more when a larger fillet is needed Use any of the weaving patterns shown in Sec tion 7 7 Remove slag before mak ing another weld pass 45 Or Less 1 2 2 1 3 B Welding Troubleshooting Table 6 1 Porosi...

Страница 39: ...nique Place stringer bead in proper location s at joint during welding Adjust work angle or widen groove to access bottom during welding Momentarily hold arc on groove side walls when using weaving technique Keep arc on leading edge of weld puddle Workpiece dirty Remove all grease oil moisture rust paint coatings slag and dirt from work surface before welding Table 6 4 Lack Of Penetration Lack Of ...

Страница 40: ...ower amperage Use smaller electrode with lower amperage Increase and or maintain steady travel speed Table 6 7 Waviness Of Bead Waviness Of Bead weld metal that is not parallel and does not cover joint formed by base metal Possible Causes Corrective Actions Unsteady hand Use two hands Practice technique Table 6 8 Distortion Distortion contraction of weld metal dur ing welding that forces base meta...

Страница 41: ...OM 316 Page 37 Return To Table Of Contents Notes ...

Страница 42: ...OM 316 Page 38 Return To Table Of Contents SECTION 8 PARTS LIST SA 802 245 E Hardware is common and not available unless listed 31 Figure 8 1 Main Assembly AC DC model illustrated ...

Страница 43: ...R AC DC 225A model 1 13 SR1 190 965 RECTIFIER AC DC 300A model 1 14 S1 124 511 SWITCH all 225A models 1 14 S1 045 834 SWITCH all 300A models 1 15 190 086 CASE SECTION 1 16 PLG1 088 297 CORD SET 230V 225A model 1 16 071 906 CABLE 460V 225A model 115 230V 225A model 1 16 204 141 CABLE all 300A models 1 17 111 443 BUSHING strain relief 230V 225A model 1 17 604 102 CONNECTOR all 300A models 460V 225A ...

Страница 44: ...OM 316 Page 40 Return To Table Of Contents Notes ...

Страница 45: ......

Страница 46: ......

Страница 47: ...3 1 Limited Warranty shall not apply to 1 Consumable components such as contact tips cutting nozzles slip rings drive rolls gas diffusers plasma torch tips and electrodes weld cables and tongs and tips or parts that fail due to normal wear Exception brushes slip rings and relays are covered on Hobart Engine Driven models 2 Items furnished by Hobart Miller but manufactured by others such as engines...

Страница 48: ...r To locate a Distributor retail or service location Call 1 877 Hobart1 or visit our website at www HobartWelders com Contact your Distributor for Welding Supplies and Consumables Options and Accessories Personal Safety Equipment Service and Repair Replacement Parts Training Schools Videos Books Technical Manuals Servicing Information and Parts Circuit Diagrams Welding Process Handbooks Contact th...