OM-285922 Page 32
6-4. Controls, MIG Mode (Menu 1 Of 5)
1
Process Select Button
Push button to enter MIG process.
Check weld parameter chart for
correct polarity at positive (+) and
negative (
−
) receptacles.
See section 5-11 for proper cable
placement.
2
Voltage Knob
Adjust voltage knob per weld pa-
rameter chart for initial setting.
3
Wire Feed Knob
Adjust wire feed knob per weld pa-
rameter chart for initial setting.
4
Display
5
Live Output Signal
.
When the symbol is activated
on the display the output is on.
The output is on in the MIG process
when the trigger on the MIG gun or
spoolgun is activated.
Ref. 287758-A
1
2
3
4
5
Содержание Multi-Handler 200
Страница 41: ...OM 285922 Page 38 SECTION 7 WELD PARAMETER CHARTS 7 1 Welding Parameters 120 Volt Ref 287984 B ...
Страница 42: ... A complete Parts List is available at www HobartWelders com OM 285922 Page 39 Ref 287984 B ...
Страница 43: ...OM 285922 Page 40 7 2 Welding Parameters 240 Volt Ref 287984 B ...
Страница 44: ... A complete Parts List is available at www HobartWelders com OM 285922 Page 41 Ref 287984 B ...
Страница 50: ...OM 285922 Page 47 Notes ...
Страница 51: ...OM 285922 Page 48 SECTION 9 ELECTRICAL DIAGRAM Figure 9 1 Circuit Diagram ...
Страница 52: ...OM 285922 Page 49 287757 A ...
Страница 74: ...Notes ...