4.6.2  Machine with drain pump

 

¾

 

Turn off the machine.

 

¾

  Remove the integral filter (

Fig.6 

) and extract the overflow (

Fig.8 

). 

¾

  After closing the door, press the 

DRAIN PUMP ACTIVATION button (2)

  

until you hear the drain cycle start. The 

CYCLE

 light 

(6)

 flashes . 

¾

  The machine turns off when draining is complete. 

 

If necessary, extract the tub filter and clean  (

Fig.7 C 

).

 

4.7

 

End of service

 

  At the end of the day always drain the machine as described in the

 

“Machine draining” section. 

 

Disconnect the power supply by means of the main switch and close the external water 
cock. 

  Perform routine maintenance and clean the machine as described in the “Maintenance” section. 

 

If possible, leave the door ajar to prevent the formation of unpleasant smells inside. 

Chap 5

 

MAINTENANCE

 

 

Completely empty the machine as described in the paragraph “Machine Emptying”, 
turn off the electricity with the main external switch and close the external water 
valve before starting any maintenance operation.

 

5.1

 

Cleaning and hygiene

 
To guarantee machine hygiene 

the routine (daily), weekly and yearly maintenance operations

indicated below must be regularly performed. Also carry out a periodical sanitising treatment with 
suitable non-corrosive products available on the market. 

5.2

 

Filtering group and machine maintenance

 

Carry out this procedure at the end of the day when you see residual dirt on the filters: 
 

1.  Remove and clean the baskets. 
2.  Remove the tub as per the instructions in the paragraph on draining the machine. 
3.  Carefully clean the integral filter.  
4.  Thoroughly clean the tank and machine with non-abrasive disinfectant products. 
5.  Remove the standard filter by pulling it upwards as shown and clean it carefully.  
6.  Do not use abrasive products or objects for cleaning the steel tank. Instead use a slightly 

soapy damp cloth.  

7.  Do not use pressurised jets of water because they could damage the electric system. 
8.  When finished with the described tasks, carefully reposition each part.

 

 

Содержание Ecomax600

Страница 1: ...integral filter 6 4 6 Emptying the machine 6 4 6 1 Machine without drain pump 6 4 6 2 Machine with drain pump 7 4 7 End of service 7 Chap 5 MAINTENANCE 7 5 1 Cleaning and hygiene 7 5 2 Filtering group...

Страница 2: ...from improper use of the machine Chap 2 INSTALLATION Proper installation is essential in order for the machine to operate well Some of the data needed for machine installation can be found on the dat...

Страница 3: ...for additional information Do not use adaptors multiple socket outlets or cables of inadequate type and section or with extension connections not compliant with plant engineering standards in force 2...

Страница 4: ...was expressly designed All other uses are to be considered unfit and therefore dangerous The specialised personnel who will install the machine are obliged to appropriately instruct the user on the ap...

Страница 5: ...ng automatically when it is turned on Heating begins when the tub is full The HEATING light 7 comes on When the tub and the boiler reach the set temperature the light goes off and the machine is ready...

Страница 6: ...s shown in Fig 4 The corresponding CYCLE light 6 will flash and the cycle begins When the cycle is complete the indicator light will go off and it you can then remove the dishes For the next cycles ju...

Страница 7: ...the main external switch and close the external water valve before starting any maintenance operation 5 1 Cleaning and hygiene To guarantee machine hygiene the routine daily weekly and yearly mainten...

Страница 8: ...ncerning reduction of use of hazardous substances in electrical and electronic equipment and disposal of waste The symbol showing a barred out dustbin on the appliance or its packaging indicates that...

Отзывы: