A complete Parts List is available at www.HobartWelders.com
OM-260 274 Page 20
5-12. Connecting 1
−
Phase Input Power For 230 VAC Input
input4 2012
−
05
−
Ref. 803 766-C / 250 332-B
L1
L2
230 VAC, 1
8
9
Tools Needed:
2
1
L1
L2
1
=GND/PE Earth Ground
6
5
3
4
7
!
Installation must meet all National and
Local Codes
−
have only qualified per-
sons make this installation.
!
Disconnect and lockout/tagout input
power before connecting input con-
ductors from unit. Follow established
procedures regarding the installation
and removal of lockout/tagout
devices.
!
Always connect green or green/yellow
conductor to supply grounding termi-
nal first, and never to a line terminal.
See rating label on unit and check input volt-
age available at site.
1
Input Power Cord
2
Disconnect Device (switch shown in the
OFF position)
3
Disconnect Device Grounding Terminal
4
Disconnect Device Line Terminals
5
Black And White Input Conductor (L1
And L2)
6
Green Or Green/Yellow Grounding
Conductor
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to dis-
connect device line terminals.
7
Over-Current Protection
Select type and size of over-current protec-
tion using Section 5-8 (fused disconnect
switch shown).
8
Receptacle (NEMA 6-50R)
Connect receptacle as shown.
Close and secure door on disconnect device.
Follow established lockout/tagout proced-
ures to put unit in service.
9
Plug (NEMA 6-50P)
Connect plug to receptacle.
input4 2012
−
05
−
803 766-C / 260 711-A