OM-240 438 Page 37
8-7. Overload Protection (Subaru-Powered Units)
244 029-A
!
Stop engine. Disconnect
negative (
−
) battery cable.
1
Fuse F1 (See Section 11-1)
F1 protects the weld excitation
winding from overload. If F1 opens,
weld output stops or is low.
2
Fuse F2 (See Section 11-1)
F2 protects the generator power
excitation winding from overload. If
F2 opens, generator power output
stops or is low.
3
Fuse F6 (See Section 11-1)
F6 protects the engine wiring sys-
tem from overload. If F6 opens,
engine will not crank.
Replace any open fuses. Reinstall
cover before operating.
NOTICE
−
If a fuse opens, it usually
indicates a more serious problem
exists. Contact a Factory Autho-
rized Service Agent.
3/8 in.
Tools Needed:
2
1
Fuses F1, F2 located on
bracket behind left side
panel.
3
Fuse F6 located in
harness behind left
side door.