OM-203 653 Page 12
4-6. Connecting Gas/Air Supply
802 787 / Ref. 801 319-C / Ref. 802 784
.
Use only clean, dry air with 70
to 150 psi (483 to 1034 kPa)
pressure.
1
Gas/Air Inlet Opening
2
Hose
3
Teflon Tape
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
4
Air Filter/Regulator
Adjust gas/air pressure according
to Section 5-1.
Tools Needed:
5/8, 1-1/8 in
3
1
4
2
From Gas/Air
Supply
Содержание AirForce 400
Страница 4: ......
Страница 28: ...OM 2229 Page 24 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram 200 809 D ...
Страница 29: ...OM 203 653 Page 25 Notes ...
Страница 33: ...Notes ...
Страница 34: ...Notes ...