8 Startup/shutdown of a mzr-pump
Operating manual mzr-11557 Ex
30
Technical data subject to change without prior notice!
Last update: March 2019
8.5
Monitoring of operation in the temperature range
Monitoring of surface temperature
Temperature range
Max. surface temperature
60°C
Table 12
Max surface temperature
Monitoring liquid temperature on pressure side
Temperature range
Max. liquid temperature
50°C
Table 13
Maximum liquid temperature
If the specified top temperature is exceeded, the pump must stop immediately.
For the monitoring the compliance with standard prEN 13463-6 has to be
respected.
8.6
Flushing procedure after use
After each service the micro annular gear pump should be carefully flushed
with a non-corrosive, filtered and particle-free flushing liquid (see table 14 and
table 15). During flushing procedure the pump should operate at a speed of
about 3000 rpm
and if possible against a low pressure (that can be obtained by
using a restrictor, a capillary or similar). The flushing liquid must be compatible
with the delivered liquid and suitable for solving the remaining liquid rests.
Depending on the application for example water, or isopropanol may be used.
If you have doubts whether a particular liquid is suitable for this function or
not, please ask the manufacturer of the liquid or HNP Mikrosysteme.