HV100 Series High Performance Current Vector Inverter
20
Chapter V Operation and display
5.1 keypad description
5.1.1 Diagram of keypad
5.1.2 Key Description
Key symbol
Name
Functional Description
PRG
Programming key
Menu entry or exit, parameter modification
ENTER
Confirm key
Enter the menu and confirm the parameter setting
▲
Incremental key
Increment of data or function code
▼
Decreasing key
Decrement of data or function code
Shift key
Select parameter modification bit and display content
RUN
Operation key
Operation under keyboard operation mode
STOP
Stop key
Stop operation
FUNC
Multifunctional keys Select according to function toggle
5.1.3 Description of function indicator lamp
Indication lamp
name
Description
REV
Inverter reverse indicator lamp, which indicates reverse operation state when it is on.
FWD
Inverter forward rotation indicator lamp, when the lamp is on, it indicates forward operation
status.
ALM
Fault indicator light, which indicates that it is in a fault state.
Hz
Frequency unit
A
Current unit
V
Voltage unit
5.1.4 Description of the combination of function indicator lights:
Combination of
indicator lights
LED display meaning
Symbol
Hz+A
Revolving speed of motor
r/min
A+V
Time (seconds)
s
Hz+V
Actual value of percentage
%
Hz+A+V
Temperature
℃