9 / 22
4.2.2
Zones
Register Address
(protocol address)
Register Address
(PLC address)
R/W Description
9
10
R/W
Zone 1/Zone 2 On/Off
3
▪
1: On/Off
▪
2: Off/On
▪
3: On/On
10
11
R
3,4
▪
1: Water temperature
▪
2: External room sensor
▪
3: Internal room sensor
▪
4: Room thermistor
▪
5: Pool Sensor
11
12
R
▪
1: Water temperature
▪
2: External room sensor
▪
3: Internal room sensor
▪
4: Room thermistor
▪
5: Pool Sensor
12
13
R/W
▪
COOL
▪
Water shift
-5..5ºC (ºC/x10ºC) // -41..41ºF
▪
Water
5..20ºC (ºC/x10ºC) // 41..68ºF
▪
Room
18..35ºC (ºC/x10ºC) // 64.4..95ºF
▪
HEAT
▪
Water shift
-5..5ºC (ºC/x10ºC) // -41..41ºF
▪
Water
20..55/65ºC (ºC/x10ºC) // 68..131/149ºF
▪
Room
10..30ºC (ºC/x10ºC) // 50..86ºF
▪
Pool
15..35ºC (ºC/x10ºC) // 59..95ºF
13
14
R/W
▪
COOL
▪
Water shift
-5..5ºC (ºC/x10ºC) // -41..41ºF
▪
Water
5..20ºC (ºC/x10ºC) // 41..68ºF
▪
Room
18..35ºC (ºC/x10ºC) // 64.4..95ºF
▪
HEAT
▪
Water shift
-5..5ºC (ºC/x10ºC) // -41..41ºF
▪
Water
20..55/65ºC (ºC/x10ºC) // 68..131/149ºF
▪
Room
10..30ºC (ºC/x10ºC) // 50..86ºF
▪
Pool
15..35ºC (ºC/x10ºC) // 59..95ºF
3
More information about zone 1 and zone 2 on Section 4.2.9
4
See Section 4.2.8 to understand the options available