Modbus interface 

  Description 

 
Intesis

 

acts as a slave device in its Modbus interface, this interface can be the Ethernet port (if using Modbus TCP), 

or the EIA232/EIA485 ports (if using Modbus RTU). To access the points and resources of the Intesis from a Modbus 
master  device,  you  must  specify  as  Modbus  register  addresses,  those  configured  inside  Intesis  corresponding  to 
KNX signals. See details below in this document. 
 
The Intesis can have Modbus RTU mode active, Modbus TCP mode active, or both modes active at the same time. 
 
 

  Functions supported 

 
This part is common for Modbus TCP & RTU. 
 
Modbus functions 01 and 02 (

coils and digital input registers

) can be used to read Modbus registers. 

 
Modbus functions 03 and 04 (

read holding registers

 and 

read input registers

) can be used to read Modbus registers. 

 
Modbus functions 05 and 15 (

Single digital Holding Registers

 and 

Write Multiple Holding Registers

) can be used to 

write Modbus registers. 
 
Modbus functions 06 and 16 (

Single Multiple Holding Registers

 and 

Write Multiple Holding Registers

) can be used 

to write Modbus registers. 
 
If 

poll records

 are used to read or write more than one register, it is necessary that the range of addresses requested 

contains valid addresses; if not the corresponding Modbus error code will be returned. 
 
All the registers are of 2 bytes, even if they are associated to signals of type bit in the external system, and its content 
is expressed in MSB..LSB. 
 
Modbus error codes are fully supported; they will be sent whenever a non-valid Modbus action or address is required. 
 

  Modbus RTU 

 
Baud rate can be selected from 1200, 2400, 4800, 9600, 19200, 38400, 56700 and 115200. 
Data Bits:8 
Parity can be selected from: none, even, odd.  
Stop Bits:1 and 2. 
 
Modbus slave number can be configured. Physical connection (EIA232 or EIA485) can also be selected. 
 
Only the lines RX, TX and GND of the EIA232 connector are used (TX/RX+ and TX/RX- for EIA485). 
 
 

  Modbus TCP 

 
The TCP port to use can be configured (by default 502 is used). 
 
The IP address, subnet mask and default router address to use by Intesis can be also configured. 
 

  Address Map 

 
The  Modbus  address  map  is  fully  configurable;  any  point  in  the  Intesis  can  be  freely  configured  with  the  desired 
Modbus register address. 
 

Содержание Intesis IBMBSKNX1000000

Страница 1: ...KNX USER MANUAL Issue date 05 2018 r1 2 ENGLISH...

Страница 2: ...nd are only intended to help improve understanding of the functionality and handling of the product In view of the wide range of possible applications of the product and because of the many variables...

Страница 3: ...URL https www intesis com 3 18 Gateway for the integration of KNX TP 1 EIB installations into Modbus RTU and or Modbus TCP enabled monitoring and control systems ORDER CODE LEGACY ORDER CODE INMBSKNX...

Страница 4: ...s RTU 8 Modbus TCP 8 Address Map 8 Points definition 9 4 Connections 10 Powering the device 11 Connection to KNX 11 Connection to Modbus 11 4 3 1 Modbus TCP 11 4 3 2 Modbus RTU 11 Connection to the co...

Страница 5: ...own KNX TP 1 EIB system and vice versa For this Intesis acts as a Modbus TCP server or Modbus RTU slave device in its Modbus interface allowing read write points from the Modbus client device s and o...

Страница 6: ...X group address With this all the Modbus system is seen as one more KNX device from the KNX system point of view with the same configuration and operation characteristics When a change in any Modbus p...

Страница 7: ...al point into Intesis is determined by the flags configured for the point See details in section 2 2 Points definition Every internal datapoint to define has the following KNX properties Property Desc...

Страница 8: ...te Modbus registers Modbus functions 06 and 16 Single Multiple Holding Registers and Write Multiple Holding Registers can be used to write Modbus registers If poll records are used to read or write mo...

Страница 9: ...ment C2 16 32 bits Float 16 bits Bitfields Error comm Function code One of the following Modbus function codes can be used 1 Read Coils 2 Read Discrete Inputs 3 Read Holding Registers 4 Read Input Reg...

Страница 10: ...abled default IP is 192 168 100 246 PortA KNX Connect the KNX TP1 bus to connectors A3 and A4 of gateway s PortA Respect the polarity PortB Modbus RTU Connect the EIA485 bus to connectors B1 B B2 A an...

Страница 11: ...1 network to the KNX port of Intesis The cable to be used shall be a straight Ethernet UTP FTP CAT5 cable 4 3 2 Modbus RTU Connect the communication cable coming from the Modbus network to the port m...

Страница 12: ...tegration are Intesis gateway Link to download the configuration tool Product documentation Intesis MAPS Configuration monitoring tool for Intesis KNX series 5 2 1 Introduction Intesis MAPS is a Windo...

Страница 13: ...ubsets of information are shown in this window General Gateway general parameters KNX KNX interface configuration and Modbus Client Modbus interface parameters Figure 5 2 Intesis MAPS configuration ta...

Страница 14: ...mmunication Console window Intesis will reboot automatically once the new configuration is loaded Figure 5 4 Intesis MAPS Receive Send tab After any configuration change do not forget to send the conf...

Страница 15: ...HMS Industrial Networks S L U All rights reserved This information is subject to change without notice URL https www intesis com 15 18 Figure 5 5 Diagnostic More information about the Diagnostic secti...

Страница 16: ...ply voltage applied WARNING In order to avoid earth loops that can damage Intesis and or any other equipment connected to it we strongly recommend The use of DC power supplies floating or with the neg...

Страница 17: ...24VDC Push Button Button A Check the user manual Button B Check the user manual Operation Temperature 0 C to 60 C Ethernet 1 x Ethernet 10 100 Mbps RJ45 2 x Ethernet LED port link and activity Operat...

Страница 18: ...reserved This information is subject to change without notice URL https www intesis com 18 18 7 Dimensions Recommended available space for its installation into a cabinet wall or DIN rail mounting wit...

Отзывы: