HMF-IRC Instruction Manual - GB
01-01
HMF TECHNICAL SERVICE DEP.
22
5.2 Starting Up of the IRC-System
Starting up of the IRC-System from the remote control box:
•
The key switch must be in position “0”
•
The stop button on the remote control box must be pulled out (turn it to the
right).
•
All control levers must be in neutral position
•
Turn the key switch into position “I”
•
The buzzer indicates: signal for approx. 3 sec. - pause for approx. 3 sec. – a
short signal
•
The indicator lamp starts to flash
•
Push the green press button (starting up the RCL).
The following is indicated:
Remote control box
The indicator lamp is flashing
Electronic box
The OPERATION diode is flashing
The SIGNAL diode is flashing
The NORMAL diode is constantly lit
RCL indicator panel
The RUN diode is constantly lit
The RCL/IRC-system is ready and loader operation can start.
5.3
Starting Up from the IRC-Remote Control Box
Alternatively the RCL/IRC-system can be started up from the remote control
box:
•
Connect the pump (PTO); the controller is thus powered
•
All stop buttons must be pulled out (there is a stop button at each control
position).
•
Start up the IRC system (see that item)
•
Push the yellow press button
twice
•
Extend the stabilizer beams and lower the stabilizer legs
Loader operation can start.