Turn on / off sound signals
Silent mode on:
Hold the 1st button to the right of the lock for four seconds until the LEDs flash green twice. The sound signals are now
switched off.
Turn on sound signals:
Press and hold the 1st button to the right of the lock for four seconds until two beeps sound. The sound signals are now
switched on.
Activate / deactivate the alarm function
Activate the alarm function:
Hold down the 4th button from the right until a sound signal sound and the green and blue LEDs light up approximately 5
times each time. The alarm function is now switched on. If the vault is then shaken, the alarm sounds.
Note:
To turn off the triggered alarm, enter your code or open the vault by using the stored fingerprint. Opening the vault with the
emergency key does not switch off the alarm.
If the alarm has been triggered, the alarm function must switched on, so that the alarm function is active again.
After using the emergency key, the alarm function remains active and does not have to be switched on again.
ISSUES
CAUSE / HANDLING
The opening mechanism is sluggish or the vault
opens only sometimes or not at all.
Weak batteries / Please open the safe with the emergency key and
insert new batteries.
When pressing the buttons no sound is heard
.
The sound signals were turned off (please note Turn on / off sound
signals).
Or weak batteries / Please open the safe with the emergency key and
insert new batteries.
When pressing the buttons no LEDs light up.
Weak batteries / Please open the safe with the emergency key and
insert new batteries.
Note:
If no batteries are inserted for an extended period of time, the vault is not reset to the factory default setting. The code and
fingerprints are still safed.
Emergency lock
Programming button
(Interior)
Holes for mounting
Battery compartment
(Interior)
Fingerprint lock
Keypad and LED indicator