5. Specifications
A.
Voltage input:
16VAC
B.
AC current:
100mA Minimum, 3A Maximum
C.
Operating temperature range: -40 F to 122 F (-40 C to 50 C)
o
o
o
o
D.
Internal Heater:
Active below 50 F (10 C)
o
0
C.
Acoustic Characteristics:
Ultrasonic, Frequency 50kHz
D.
Angle of Detection:
Target must be perpendicular ± 15 @ 3 feet (.91 meter).
0
E.
Detection Range:
1 to 7 (±1) feet (.30 to 2.13 meter, ±.30 meter)
F.
Turn On Delay:
2 (±.5) seconds
G.
Turn Off Delay:
.5 (±.3) seconds
H.
Connectors:
None
I.
Controls:
None
J.
Indicators:
None
K.
Vehicle Detection Output:
Relay Closure (SPST, normally open)
Maximum Switching Power, 10VA
Maximum Switching Voltage, 100VDC or peak AC
Maximum Switching Current, 0.50 A
Maximum Carry Current, 1.00 A
L.
Cables:
AC Power Input:
2 conductor (16 AWG) cable 12 feet (3.66 meters) long.
Vehicle Detector Output:
2 conductor (24 AWG) cable 12 feet (3.66 meters) long.
Cables can be extended to 200 feet (61 meters) maximum.
M.
Weight:
1.5 lbs (.68 Kg)
N.
Dimensions:
4.6 x 5.6 x 3.9 inches (116.84 x 142.24 x 99.06 mm)