User Guide | FreeSpeak Edge Base Station
4.3
Using IP Transceivers with the Base Station
This setup has a total of 6 FS Edge transceivers with 16 Beltpacks connected. The IP
transceivers are connected via a network that is configured for AES67 traffic. These are
configured using the CCM. There are four 2-wire partylines and a Dante network.
Note:
The Dante network must be on a different VLAN or network from the IP transceivers.
Note:
The AES67 network must be set up correctly for the IP transceivers in order to meet the needs
of Clear-Com IP transceivers for high levels of PTP accuracy.