Usage Preparation   

 

 

 

 

 

 

 

1. Installation   

 

 

 

 

 

 - Let the space between rear side of the 
cabinet to the wall be at least 30 cm. 

 - Should not install the cabinet near any 
equipment that can reject such as 
microwave oven, burner, or any other 
refrigerator. 

 - Should install the cabinet in shaded area 
(not exposed to the sunlight or rain)   

- Should install the cabinet in good ventilation 
area. 

 

 

 

 

 

 

 

 

2. Electricity 

 - Connect the plug of the cabinet to the 
same standard electrical socket. 

 - Should prepare single set of socket for each 
cabinet and avoid joining the socket with 
other  electrical equipment. 

 - At least 1.5 square mm. Diameter is 
recommended for the electrical wire 
supplying to the socket terminal. 

 - Prepare 15 Ampere fuse for each cabinet. 

 - For 220 volt Electricity System, Ensure 220 
Volt ± 10% (198-242 Volt) electricity is supplied. 
For 110 Volt Electricity System, Ensure 110 Volt 
± 10% (99-121 volt) electricity is supplied.   

3. Start Run  

 

    The cabinet should be operated about 2 
hours in advance of containing the eutectic 
packs. 

 

 

 

 

 

 

 

 

 

USER 

MANUAL

 

PF-10,PF-12,PF-20,PF-22

 

 

Содержание PF-10

Страница 1: ...1 SHELE CONTACT FREEZER PF 10 PF 12 PF 20 PF 22 USER MANUAL PF 10 PF 12 PF 20 PF 22 CONTACT 73 10170 662 887 6006 662 887 6009 Web thanakoon com...

Страница 2: ...to the same standard electrical socket Should prepare single set of socket for each cabinet and avoid joining the socket with other electrical equipment At least 1 5 square mm Diameter is recommended...

Страница 3: ...sition before closing the cabinet door 5 In order to prevent thick frost should quickly contain the packs within 15 minutes 6 After containing the packs should keep the cabinet closed for 23 hour cont...

Страница 4: ...er does contribute damage to the cabinet and electronics temperature controller 2 At any opening and closing the cabinet door should keep 5 minut intermission for re opening Due to high amount of pres...

Страница 5: ...s aerosol cans with a flammable propellant in this appliance 5 lf the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid...

Страница 6: ...6 1 30 1 2 1 5 FUSE 15 220 220 10 198 242 110 110 10 99 121 3 2 35 40 C PF 10 PF 12 PF 20 PF 22...

Страница 7: ...7 EUTECTIC PACK 1 2 3 4 5 15 FROST 6 23 DEFROSTING 1 5 PF 10 PF 12 PF 20 PF 22...

Страница 8: ...8 1 2 3 BLOWER 4 5 BLOWER 1 1 PF 10 PF 12 PF 20 PF 22...

Страница 9: ...9 2 5 3 4 5 PF 10 PF 12 PF 20 PF 22...

Страница 10: ...ctions shown in this user manual Damages from accidence natural disaster or mis operation are out of our guarantee scope Adjustment modification or repair to any cabinet s equipment by unauthorized pe...

Отзывы: