background image

LINEAR 9   1.0

5

8

    

Preset

Use the Preset selection button to call up factory presets or a user preset 
you can configure via the remote DSP CONTROL software. Tap the select 
button once to scroll through Presets 1 through 4. 
A separate manual explains how to program the four remote user presets. 
You will find it on the LINEAR 9 download page at www.hkaudio.com.

A look at the presets:

L9 210 LTA

L9 110 XA / L9 112 XA L9 118 Sub A / L9 118 Sub BA

Remote

1

2

3

4

Remote

1

2

3

4

Remote

1

2

3

4

Flat

Low Cut

Monitor

Front

Cardioid 1:1

Cardioid 2:1

Remote

1

2

3

4

Remote

1

2

3

4

Remote

1

2

3

4

Flat

Low Cut

Monitor

Front

Cardioid 1:1

Cardioid 2:1

Remote

1

2

3

4

Remote

1

2

3

4

Remote

1

2

3

4

Flat

Low Cut

Monitor

Front

Cardioid 1:1

Cardioid 2:1

1

Stand Alone

Flat

Front

2

Cluster (2)

Monitor

Cardioid 1:1

3

Cluster (3)

Low Cut

Cardioid 2:1

4

Remote  (to access stored settings via the remote  

HK Audio DSP CONTROL software)

Factory presets: LINEAR 9 210 LTA

Stand Alone

for a single L9 210 LTA (per side)

Cluster (2)

for two connected L9 210 LTA units

Cluster (3)

for three connected L9 210 LTA units

Factory presets: LINEAR 9 110 XA • LINEAR 9 112 XA

Flat

Delivers linear response across the full frequency range

Monitor

Optimized to dampen the extra bass generated by floor 
coupling when you set a speaker on its side for use as a 
monitor

Low Cut

A high-pass filter optimizes the unit for use as a mid/high 
unit paired with the L9 118 Sub A/L9 118 Sub BA 

Factory presets: LINEAR 9 118 Sub A • LINEAR 9 118 Sub BA

Front

Standard operating mode for a forward-facing subwoofer

Cardioid 1:1

For cardioid setups with one forward-facing L9 118 Sub A/
L9 118 Sub BA; see section 4.2 for more on this

Cardioid 2:1

For cardioid setups with two forward-facing L9 118 Sub A/
L9 118 Sub BA; see section 4.2 for more on this

Factory presets 1 to 3 address the speaker only and not the DSP Out.  

Heads up: If you are operating the speaker in a network connected to 

the remote DSP CONTROL software, you can configure the DSP Out 

independently even when using factory presets 1 to 3. To learn more 

about this, consult the separate DSP CONTROL manual. You will find it 

on the LINEAR 9 download page at www.hkaudio.com.

The Remote Preset

Remote

This lets you call up a user preset that you previously stored 
via DSP CONTROL for the speaker as well as for the DSP 
Out. The speakers does not need to be connected to the 
remote software to do this. 

The remote preset's default setup is identical to factory preset 1 (Stand 
Alone/Flat/Front).  

You can access the following DSP functions via the remote DSP CONTROL 

software and save your settings in user presets:

Fully parametric 10-band EQ with variable filter characteristics for each 
frequency band, high-pass and low-pass filters with variable filter 
characteristics, Limiter, Delay, Polarity, Level, and Mute 

You can configure these parameters separately and independently for the 
speaker and its DSP Out.

Screenshot of the remote DSP CONTROL software. You can download this software free of charge at the 
LINEAR 9 product page at www.hkaudio.com. The speaker and DSP Out parameters are identical, but 
the powerful onboard DSP lets you configure each set independently.

9

    

Power

This rocker switch turns the power on and off. Set it to Power to turn the 
electronic components on and to Off to disconnect them from the mains 
power supply. The Power switch does not affect the Powercon Link port. 
See section 

12  

 below for more on this. 

10

    

Power-LED

This LED lights up green when the electronic components are getting mains 
power.

11

    

Mains Input 

Use the factory-included Powercon mains cord 
to connect this socket to a power outlet. Insert 
the push-pull connector and turn it clockwise 
to make sure the Powercon cord engages and 
locks. To unlock it, pull the Powercon plug's 
locking mechanism towards the cable and turn it 
counterclockwise.

Leave enough space for proper ventilation!

LINEAR 7

118 Sub A

MADE IN GERMANY

Power

Auto Sleep

On

Off

+6 dB

–6 dB

0 dB

Input

L

R

DSP Out

Thru

Gain

Serial No.

Mains Input

100-240 V~   50-60 Hz   

1.9 A @ 1/8 output power

Link

100-240 V~   50-60 Hz

max. 10 A   

Caution: Risk of electric shock! Do not open! 
Refer servicing to qualified service personnel.
Attention: Risque de choc élèctrique – 
ne pas ouvrir!

HK Audio is a brand of Stamer Musikanlagen GmbH
Magdeburger Str. 8 • 66606 St. Wendel • Germany

Power

Lock

Lock

1

5

2

1

2

3

4

4

9

11

12

10

13

12

    

Link

 

 

This socket can power up to three additional LINEAR 9 
speaker cabinets. Hardwired to the Mains Input, it is not 
affected by the Power switch setting. The Link circuit 
goes live the moment you connect the Mains Input to 
a power source. This is why you must make sure all 
downstream devices are switched off before you connect 
them to the Link port.

• English

• Deutsch

Leave enough space for proper ventilation!

LINEAR 7

118 Sub A

MADE IN GERMANY

Power

Auto Sleep

On

Off

+6 dB

–6 dB

0 dB

Input

L

R

DSP Out

Thru

Gain

Serial No.

Mains Input

100-240 V~   50-60 Hz   

1.9 A @ 1/8 output power

Link

100-240 V~   50-60 Hz

max. 10 A   

Caution: Risk of electric shock! Do not open! 
Refer servicing to qualified service personnel.
Attention: Risque de choc élèctrique – 
ne pas ouvrir!

HK Audio is a brand of Stamer Musikanlagen GmbH
Magdeburger Str. 8 • 66606 St. Wendel • Germany

Power

Lock

Lock

1

5

2

1

2

3

4

4

9

11

12

10

13

Содержание LINEAR 9 110 XA

Страница 1: ...Manual 1 0 English Deutsch LINEAR 9 LINEAR 9 210 LTA LINEAR 9 110 XA LINEAR 9 112 XA LINEAR 9 118 Sub A LINEAR 9 118 Sub BA Fran ais Italiano Espa ol download at www hkaudio com...

Страница 2: ...recommended by the manufacturer this applies for all kind of accessories for example protective covers transport bags stands wall or ceiling mounting equipment In case of attaching any kind of access...

Страница 3: ...t sound at every occasion Your HK Audio team Strong electromagnetic interference or electrostatic discharge may prevent the product from functioning normally If this happens the product may be returne...

Страница 4: ...signal The control range for the mid high units sweeps from mute to 6 dB The preamp Gain control on each of the two subwoofers addresses both channels with a control range sweeping from 6 to 6 dB The...

Страница 5: ...via DSP CONTROL for the speaker as well as for the DSP Out The speakers does not need to be connected to the remote software to do this The remote preset s default setup is identical to factory preset...

Страница 6: ...cabs on its side for use as a stage monitor In fact the upright speaker s narrower vertical throw pattern works great in the horizontal position Its tightly focused directivity minimizes overlap with...

Страница 7: ...eset 1 60 Select the appropriate preset on the back of the speakers for the given type of cluster 4 2 LINEAR 9 118 Sub A LINEAR 9 118 Sub BA Deploy the LINEAR 9 118 Sub A as you would any other direct...

Страница 8: ...A Front L9 118 Sub BA Front 5 4 Configuring a 1 1 Cardioid Setup Use a speaker pole to set up 1 1 cardioid systems Aim the bottom subwoofers to the rear Presets Mid high units Low Cut L9 118 Sub A to...

Страница 9: ...variable filter characteristics High Pass Filter Low Pass Filter Polarity Level Delay Limiter Mute Fully parametric 10 band EQ with variable filter characteris tics High Pass Filter Low Pass Filter Po...

Страница 10: ...wird seien Sie vorsichtig wenn Sie die Rollwagen Ger te Kombination transportieren um Verletzungen durch Umkippen zu vermeiden Verwenden Sie nur Zubeh r das vom Hersteller empfohlen ist Das gilt f r a...

Страница 11: ...Wir w nschen Ihnen allzeit besten Sound Ihr HK Audio Team Hinweis Die Funktionalit t dieses Produkts kann durch starke elektromagnetische Felder oder elektrostatische Entladungen gest rt werden In die...

Страница 12: ...ei der Stereo Vorstufe der beiden Subwoofer gilt der Regler f r beide Kan le hier ist der Regelbereich 6 bis 6 dB Mittelstellung des Reglers Centerclick entspricht in beiden F llen 0 dB Hinweis Das Si...

Страница 13: ...ONTROL gespeichertes User Preset f r die Box selbst als auch f r den DSP Out ab gerufen werden Die Box muss dazu nicht mit der Remote Software verbunden sein Im Auslieferungszustand entspricht das Rem...

Страница 14: ...ogene Abstrahlung im Nahfeld ausgestattet das Horn der 12 Box LINEAR 9 112 XA bietet mittlere Abstrahlwinkel von 70 x 50 Tipp Beim Einsatz als quer liegender B hnen Monitor XA Modelle ist es nicht zwi...

Страница 15: ...3 25 25 Stand alone Preset 1 60 Je nach gew hltem Cluster muss das entsprechende Preset auf der R cksei te der Lautsprecher angew hlt werden 4 2 LINEAR 9 118 Sub A LINEAR 9 118 Sub BA Der LINEAR 9 118...

Страница 16: ...als Cardioid Setup 1 1 Cardioid System mit Distanzstange die unteren B sse sind nach hinten gerichtet Presets Mid High Units Low Cut L9 118 Sub A oben Front L9 118 Sub A unten Cardioid 1 1 5 5 Aufbau...

Страница 17: ...d EQ mit variabler Filter Charakteris tik High Pass Filter Low Pass Filter Polarit t Level Delay Limiter Mute Vollparametrischer 10 Band EQ mit variabler Filter Charakteris tik High Pass Filter Low Pa...

Страница 18: ...509 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 international hkaudio com Subject to change without notice Technische nderungen vorbehalten Co...

Отзывы: